Shake table tests of three storey cold-formed steel structures with strap-braced walls

被引:0
|
作者
Luigi Fiorino
Bianca Bucciero
Raffaele Landolfo
机构
[1] University of Naples “Federico II”,Department of Structures for Engineering and Architecture
来源
关键词
Cold-formed steel; Lightweight steel; Stick-built construction; Seismic performance; Shake table tests;
D O I
暂无
中图分类号
学科分类号
摘要
This study aims to increase the knowledge of the seismic behaviour of low-to-medium rise structures, in which the seismic force-resisting system is provided by cold-formed steel strap-braced walls designed as non-energy-dissipating systems. The dynamic response of this system under seismic actions is analysed by performing shake table tests on two reduced-scale (1:3) three-storey two-bay prototypes, that differed in floor typology: steel–concrete floors (Type 1) or floors made of wood-based panels (Type 2). Main outcomes show that the seismic response can be considered as satisfactory, because the system seems to have inherent ductility even without a designated energy dissipating mechanism. In particular, the seismic response was approximately linear for tests having intensity not greater than that assumed for the design, whereas for tests having higher intensities the behaviour deviated from the linearity, with maximum interstorey drift angles greater than 2% without very extensive damage, and in-plane floor rigid behaviour for both prototypes according to the ASCE 7 definition.
引用
收藏
页码:4217 / 4245
页数:28
相关论文
共 50 条
  • [1] Shake table tests of three storey cold-formed steel structures with strap-braced walls
    Fiorino, Luigi
    Bucciero, Bianca
    Landolfo, Raffaele
    BULLETIN OF EARTHQUAKE ENGINEERING, 2019, 17 (07) : 4217 - 4245
  • [2] A numerical study on seismic performance of strap-braced cold-formed steel shear walls
    Zeynalian, M.
    Ronagh, H. R.
    THIN-WALLED STRUCTURES, 2012, 60 : 229 - 238
  • [3] Inelastic performance of screw-connected cold-formed steel strap-braced walls
    Al-Kharat, M.
    Rogers, C. A.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2008, 35 (01) : 11 - 26
  • [4] Experimental Study on Seismic Performance of Strap-Braced Cold-Formed Steel Shear Walls
    Zeynalian, Mehran
    Ronagh, Hamid
    ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (02) : 245 - 257
  • [5] Seismic capacity-based design of narrow strap-braced cold-formed steel walls
    Mirzaei, A.
    Sangree, R. H.
    Velchev, K.
    Comeau, G.
    Balh, N.
    Rogers, C. A.
    Schafer, B. W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 115 : 81 - 91
  • [6] Inelastic performance of cold-formed steel strap braced walls
    Al-Kharat, M.
    Rogers, C. A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (04) : 460 - 474
  • [7] Numerical modeling of the post-fire performance of strap-braced cold-formed steel shear walls
    Ni, Shuna
    Yan, Xia
    Hoehler, Matthew S.
    Gernay, Thomas
    THIN-WALLED STRUCTURES, 2022, 171
  • [8] Performance of light-gauge cold-formed steel strap-braced stud walls subjected to cyclic loading
    Moghimi, Hassan
    Ronagh, Hamid R.
    ENGINEERING STRUCTURES, 2009, 31 (01) : 69 - 83
  • [9] Parametric study on seismic response modification factor of strap-braced cold-formed steel systems
    Abbasi, Mehran
    Riahi, Hossein Tajmir
    Zeynalian, Mehran
    Rahnama, Mohammad Younes
    STRUCTURES, 2024, 60
  • [10] Experimental investigation on seismic performance of cold-formed steel strap-braced stud walls under lateral cyclic and vertical loading
    Rad, Pouya Lotfi
    Clifton, Charles
    Lim, James
    Hajirasouliha, Iman
    THIN-WALLED STRUCTURES, 2024, 194