Fluorescence X-ray computed tomography (FXCT) using a position-sensitive CdTe detector

被引:0
|
作者
Changyeon Yoon
Wonho Lee
机构
[1] Korea University,Department of Bio
来源
关键词
FXCT; 2D CdTe detector; Characteristic X-ray;
D O I
暂无
中图分类号
学科分类号
摘要
This research involved a 3D simulation of a non-destructive test to detect fluorescence X-rays with a position-sensitive CdTe detector. Simulations were performed under various conditions and on different types of phantoms. All simulations were based on fluorescence X-ray computed tomography (FXCT) using a Monte Carlo method. In general, conventional computed tomography (CT) analyzes materials based on their attenuation coefficients, and is highly dependent on the densities of the materials; hence, discriminating between materials of similar density can be difficult, even if their atomic numbers differ. In this research, the material was exposed to an X-ray source, and the characteristic X-ray was measured by using a 2-dimensional (2D) CdTe planar detector array and was then used to reconstruct a 3-dimensional (3D) image. A 2D CdTe pixelated array has a large detection area and operates with a compact cooling device. Because atoms have their own characteristic X-ray energy spectra, our system was even able to discriminate between materials with similar densities, provided the materials were composed of elements with different atomic numbers. In this research, FXCT was applied to distinguish between various materials, and real-world simulations were performed to verify the feasibility of our system for non-destructive inspection applications.
引用
收藏
页码:122 / 128
页数:6
相关论文
共 50 条
  • [1] Fluorescence X-ray computed tomography (FXCT) using a position-sensitive CdTe detector
    Yoon, Changyeon
    Lee, Wonho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (01) : 122 - 128
  • [2] Fluorescence X-ray Computed Tomography Using CdTe Detector Array
    Yoon, Changyeon
    Lee, Wonho
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [3] POSITION-SENSITIVE X-RAY DETECTOR
    GABRIEL, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (10): : 1303 - 1305
  • [4] POSITION-SENSITIVE X-RAY DETECTOR.
    Duval, B.P.
    Barth, J.
    Deslattes, R.D.
    Henins, A.
    Luther, G.G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1983, 222 (1-2) : 274 - 278
  • [5] NEW CURVED X-RAY POSITION-SENSITIVE DETECTOR
    IZUMI, T
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1978, 17 (06) : 1161 - 1162
  • [6] Recording of x-ray holograms on a position-sensitive detector
    Kopecky, M
    Busetto, E
    Lausi, A
    Miculin, M
    Savoia, A
    APPLIED PHYSICS LETTERS, 2001, 78 (19) : 2985 - 2987
  • [7] CURVED POSITION-SENSITIVE DETECTOR FOR X-RAY CRYSTALLOGRAPHY
    IZUMI, T
    NUCLEAR INSTRUMENTS & METHODS, 1980, 177 (2-3): : 405 - 409
  • [8] Energy- and position-sensitive pixel detector Timepix for X-ray fluorescence imaging
    Zemlicka, Jan
    Jakubek, Jan
    Kroupa, Martin
    Tichy, Vladimir
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 202 - 204
  • [9] AN X-RAY SPECTROMETER WITH A POSITION-SENSITIVE WIRE DETECTOR (PSD)
    EBEL, H
    MANTLER, M
    GURKER, N
    WERNISCH, J
    X-RAY SPECTROMETRY, 1983, 12 (01) : 47 - 49
  • [10] Comparison of a Large Area CZT Detector to a Spectroscopic CdTe Detector for X-ray Fluorescence Computed 'Tomography
    Vernekohl, Don
    Streicher, Michael
    Ahmad, Moiz
    Xing, Lei
    He, Zhong
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,