Standardized full-field electroretinography in rabbits

被引:0
|
作者
Karin Gjörloff
Sten Andréasson
Berndt Ehinger
机构
[1] Lund University Hospital,Wallenberg Retina Center, Department of Ophthalmology
[2] Wallenberg Retina Center,Department of Ophthalmology
[3] BMC B13,undefined
来源
Documenta Ophthalmologica | 2004年 / 109卷
关键词
electroretinogram; electrodes; Ganzfeld stimulation; rabbit; standards;
D O I
暂无
中图分类号
学科分类号
摘要
We present a procedure for full-field ERG recording in rabbits, based on the human ERG standards published by the International Society for Clinical Electrophysiology of Vision (ISCEV). Following initial pilot experiments, six animals aged 3 months and 11 animals between 1 and 2 years were investigated. All animals displayed well detectable and reproducible separate cone and rod responses under appropriate stimulus conditions. The b-wave was smaller in young animals than in old, but there were no similar differences in the b-wave implicit times. The animals had to be lightly sedated, which was shown to have no adverse effects on the recordings. Standard deviations of normalized adult rabbit recordings were comparable to human recordings. The measurements were less precise in young animals. We suggest that our procedure is well suited for further scientific studies in this animal model.
引用
收藏
页码:163 / 168
页数:5
相关论文
共 50 条
  • [1] Standardized full-field electroretinography in rabbits
    Gjörloff, K
    Andréasson, S
    Ehinger, B
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2004, 109 (02) : 163 - 168
  • [2] Standardized full-field and multifocal electroretinography in rabbits
    Gjorloff, KW
    Ghosh, F
    Andréasson, S
    Ehinger, B
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U31 - U31
  • [3] Standardized Full-Field Electroretinography in the Green Monkey (Chlorocebus sabaeus)
    Bouskila, Joseph
    Javadi, Pasha
    Palmour, Roberta M.
    Bouchard, Jean-Francois
    Ptito, Maurice
    [J]. PLOS ONE, 2014, 9 (10):
  • [4] STANDARDIZED FULL-FIELD ELECTRORETINOGRAPHY - NORMAL VALUES AND THEIR VARIATION WITH AGE
    BIRCH, DG
    ANDERSON, JL
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (11) : 1571 - 1576
  • [5] FULL-FIELD SYSTEM FOR CLINICAL ELECTRORETINOGRAPHY
    RABIN, AR
    BERSON, EL
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1974, 92 (01) : 59 - 63
  • [6] Standard full-field electroretinography in healthy preterm infants
    Adriana Berezovsky
    Nilva Simeren Bueno Moraes
    Steven Nusinowitz
    Solange Rios Salomão
    [J]. Documenta Ophthalmologica, 2003, 107 : 243 - 249
  • [7] Full-field electroretinography under general anesthesia in retinoblastoma
    Ramya Sachidanandam
    S. Krishnakumar
    Lingam Gopal
    Joan M. O’Brien
    Vikas Khetan
    Parveen Sen
    [J]. Documenta Ophthalmologica, 2013, 126 : 149 - 157
  • [8] Full-field electroretinography in young patients with Usher syndrome
    Malm, E.
    Ponjavic, V
    Andreasson, S.
    [J]. ACTA OPHTHALMOLOGICA, 2008, 86 : 29 - 29
  • [9] Standard full-field electroretinography in healthy preterm infants
    Berezovsky, A
    Moraes, NSB
    Nusinowitz, S
    Salomao, SR
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2003, 107 (03) : 243 - 249
  • [10] Full-field electroretinography - when do we need it?
    Khan, Arif O.
    [J]. SAUDI JOURNAL OF OPHTHALMOLOGY, 2023, 37 (04) : 263 - 268