Comparison of different methods for measuring intra-abdominal pressure

被引:0
|
作者
F. Gudmundsson
A. Viste
H. Gislason
K. Svanes
机构
[1] Surgical Research Laboratory,
[2] Haukeland University Hospital,undefined
[3] University of Bergen,undefined
来源
Intensive Care Medicine | 2002年 / 28卷
关键词
Intra-abdominal pressure Urinary bladder pressure Femoral vein pressure Inferior caval vein pressure Porcine model;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: Intra-abdominal pressure (IAP) can be measured in different ways but is usually measured indirectly via the urinary bladder. The aim of the study was to: 1) compare urinary bladder pressure, femoral vein pressure, and inferior caval vein pressure with IAP at different levels of IAP; and 2) try to find an optimal amount of fluid to be instilled into the urinary bladder before measurement of the bladder pressure, and to compare changes in blood flow in the femoral vein with that in the caval vein at different pressure levels. Design: Experimental study. Setting: Animal research laboratory. Subjects: Eight domestic swine of both sexes, weighing 30.6±2.9 kg (mean±SD). Interventions: Catheters connected to pressure transducers were placed into the urinary bladder, the inferior caval vein, the femoral vein, and the superior caval vein. Transit time flow probes were placed around the inferior caval vein and the femoral vein. After a stabilizing period, the abdominal pressure was increased stepwise by instillation of Ringer's solution into the abdomen and then decreased. Thereafter, we instilled fluid into the bladder at an IAP of 8 mmHg and at 20 mmHg and measured the amount of fluid needed to elevate the intra-vesical pressure by 2 mmHg. Results: The pressures recorded in the urinary bladder, the inferior caval vein, and the femoral vein reflected the pressure in the abdominal cavity very well. The fluid volume needed to increase the bladder pressure by 2 mmHg was significantly lower at 20 mmHg IAP than at 8 mmHg. Blood flow in the femoral vein and the inferior caval vein showed a similar pattern and decreased when the intra-abdominal pressure increased. Conclusions: In our porcine model, and increasing the IAP by means of instillation of Ringer's solution, a reliable estimation of the IAP was obtained by measuring the pressure in the urinary bladder, the femoral vein or the inferior caval vein. The IAP estimated indirectly as the urinary bladder pressure is affected by the amount of fluid in the bladder, which should not exceed 10–15 ml. The decrease in femoral vein blood flow reflects the changes in inferior caval vein flow during increased IAP.
引用
收藏
页码:509 / 514
页数:5
相关论文
共 50 条
  • [1] Comparison of different methods for measuring intra-abdominal pressure
    Gudmundsson, FF
    Viste, A
    Gislason, H
    Svanes, K
    [J]. INTENSIVE CARE MEDICINE, 2002, 28 (04) : 509 - 514
  • [2] Comparison of indirect methods of measuring intra-abdominal pressure in children
    Peter J. Davis
    Satajyit Koottayi
    Anna Taylor
    Warwick W. Butt
    [J]. Intensive Care Medicine, 2005, 31 : 471 - 475
  • [3] Comparison of indirect methods of measuring intra-abdominal pressure in children
    Davis, P
    Koottayi, S
    Taylor, A
    Butt, W
    [J]. INTENSIVE CARE MEDICINE, 2005, 31 (03) : 471 - 475
  • [4] Measuring intra-abdominal pressure: A comparison of current methods to two novel techniques
    McNeil, JD
    Smith, DL
    Josephs, JD
    Frankel, H
    Mueller, D
    Muskat, P
    Jenkins, D
    [J]. CRITICAL CARE MEDICINE, 2000, 28 (12) : A135 - A135
  • [5] Capacitive Sensor for Measuring of Intra-Abdominal Pressure
    Jurcisin, Michal
    Slosarcik, Stanislav
    Gmiterko, Alexander
    Cabuk, Pavol
    [J]. 2011 34TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY (ISSE 2011) - NEW TRENDS IN MICRO/NANOTECHNOLOGY, 2011, : 583 - 586
  • [6] Intra-Abdominal Pressure: Why Are You Not Measuring It?
    Cheatham, Michael L.
    [J]. CRITICAL CARE MEDICINE, 2014, 42 (02) : 467 - 469
  • [7] Diagnostic techniques and ways of measuring intra-abdominal pressure
    Zivcak, J.
    Liberko, I.
    Molcanyi, T.
    [J]. 2010 IEEE 8TH INTERNATIONAL SYMPOSIUM ON APPLIED MACHINE INTELLIGENCE AND INFORMATICS, 2010, : 305 - +
  • [8] Measuring intra-abdominal pressure in newborns with malformations of GIT
    Draskovic, BG
    Borisev, V
    Grebeldinger, S
    Tatic, M
    [J]. INTENSIVE CARE MEDICINE, 2003, 29 : S111 - S111
  • [9] Noninvasive monitoring of intra-abdominal pressure by measuring abdominal wall tension
    Yuanzhuo Chen
    Shuying Yan
    Yanqing Chen
    Yugang Zhuang
    Zhao Wei
    Shuqin Zhou
    Hu Peng
    [J]. World Journal of Emergency Medicine, 2015, 6 (02) - 141
  • [10] Noninvasive monitoring of intra-abdominal pressure by measuring abdominal wall tension
    Chen, Yuan-zhou
    Yan, Shu-ying
    Chen, Yan-qing
    Zhuang, Yu-gang
    Wei, Zhao
    Zhou, Shu-qin
    Peng, Hu
    [J]. WORLD JOURNAL OF EMERGENCY MEDICINE, 2015, 6 (02) : 137 - 141