Effect of PEEP on work of breathing in mechanically ventilated COPD patients

被引:0
|
作者
C. Guerin
J. Milic-Emili
G. Fournier
机构
[1] Service de Réanimation Médicale et Assistance Respiratoire,
[2] Hôpital de la Croix-Rousse,undefined
[3] 103 grande rue de la Croix-Rousse,undefined
[4] 69004 Lyon,undefined
[5] France e-mail: c-guerin@univ-lyon1.fr Tel.: + 33-4-72 07 17 62 Fax: + 33-4-72 07 17 74,undefined
[6] Service de Réanimation Médicale,undefined
[7] Centre Hospitalier Lyon-Sud,undefined
[8] Pierre Bénite,undefined
[9] France,undefined
[10] Meakins-Christie laboratories,undefined
[11] McGill University,undefined
[12] Montreal,undefined
[13] Quebec,undefined
[14] Canada,undefined
来源
Intensive Care Medicine | 2000年 / 26卷
关键词
Key words Work of breathing; Chronic obstructive pulmonary disease; Mechanical ventilation; Pulmonary hyperinflation; Positive end-expiratory pressure;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: To study the effects of PEEP on the inspiratory work done per breath on the respiratory system (WI,rs) in patients with chronic obstructive pulmonary disease (COPD).¶Design: Physiological study.¶Setting: Fourteen-bed Medical ICU of a 1000-bed teaching tertiary hospital.¶Patients and participants: Ten patients with COPD intubated and mechanically ventilated for acute respiratory failure.¶Interventions: PEEP of 0 (ZEEP), ¶5, 10, and 15 cm H2O were applied randomly and measurements done at the end of a 15–20 min period.¶Measurements and results: Using the rapid airway occlusion technique during constant flow inflation, we partitioned WI,rs into its static and dynamic components. On ZEEP, the mean ± SD values of WI,rs amounted to 15.1 ± 5.7 cm H2O × l. With increasing PEEP, WI,rs was significantly reduced to 12.6 ± 5.7, 11.1 ± 4.1, and 10.4 ± 2.8 cm H2O × l at PEEP of 5, 10, and 15 cm H2O, respectively (P < 0.05). This reduction was entirely due to the decline of the work due to intrinsic PEEP (PEEPi) and was abolished when the applied PEEP counterbalanced PEEPi. The other components of WI,rs were not affected by PEEP. By increasing PEEP up to the level of PEEPi on ZEEP, no further increase in end-expiratory lung volume was observed.¶Conclusions: In COPD patients the application of PEEP levels close to PEEPi can substantially reduce WI,rs without promoting further dynamic pulmonary hyperinflation.
引用
收藏
页码:1207 / 1214
页数:7
相关论文
共 50 条
  • [1] Effect of PEEP on work of breathing in mechanically ventilated COPD patients
    Guerin, C
    Milic-Emili, J
    Fournier, G
    INTENSIVE CARE MEDICINE, 2000, 26 (09) : 1207 - 1214
  • [2] PARTITIONING OF WORK OF BREATHING IN MECHANICALLY VENTILATED COPD PATIENTS
    COUSSA, ML
    GUERIN, C
    EISSA, NT
    CORBEIL, C
    CHASSE, M
    BRAIDY, J
    MATAR, N
    MILICEMILI, J
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (04) : 1711 - 1719
  • [3] The work of breathing of mechanically ventilated patients
    Fernando, T
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 255 - 258
  • [4] Partitioning of work of breathing in mechanically ventilated COPD patients: Effects of body position
    Mentzelopoulos, SD
    Sigala, JS
    Roussos, C
    Zakynthinos, SG
    INTENSIVE CARE MEDICINE, 2001, 27 : S267 - S267
  • [5] Effects of PEEP on inspiratory resistance in mechanically ventilated COPD patients
    Guérin, C
    Fournier, G
    Milic-Emili, J
    EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (03) : 491 - 498
  • [6] The comparative effect of helium-oxygen and external peep in mechanically ventilated COPD patients
    Roeseler, J
    Jolliet, P
    Watremez, C
    Detry, B
    Clerbaux, T
    Gianello, P
    De Kock, M
    Liistro, G
    INTENSIVE CARE MEDICINE, 2003, 29 : S17 - S17
  • [7] Influence of PEEP on volume dependence of resistance in mechanically ventilated COPD patients
    Vassiliou, MP
    Amygdalou, A
    Leontaridi, C
    Moukas, M
    Raptis, C
    Katsanos, C
    Mandragos, C
    Behrakis, PK
    INTENSIVE CARE MEDICINE, 2002, 28 : S71 - S71
  • [8] WORK OF BREATHING AS A WEANING PARAMETER IN MECHANICALLY VENTILATED PATIENTS
    LEVY, MM
    MIYASAKI, A
    LANGSTON, D
    CHEST, 1995, 108 (04) : 1018 - 1020
  • [9] Static and dynamic intrinsic PEEP and respiratory mechanics in mechanically ventilated COPD patients
    Antonaglia, V
    Peratoner, A
    De Simoni, L
    ANAESTHESIA, PAIN, INTENSIVE CARE AND EMERGENCY MEDICINE - APICE 14, 2000, : 153 - 159
  • [10] Pattern of lung emptying in mechanically ventilated COPD patients-effects of peep
    Kondili, E
    Alexopoulou, C
    Prinianakis, G
    Xirouchaki, N
    Kate, H
    Georgopoulos, D
    INTENSIVE CARE MEDICINE, 2003, 29 : S147 - S147