DXA of the Hip and Heel Ultrasound but not Densitometry of the Fingers Can Discriminate Female Hip Fracture Patients from Controls: A Comparison Between Four Different Methods

被引:0
|
作者
A. Ekman
K. Michaëlsson
M. Petrén-Mallmin
S. Ljunghall
H. Mallmin
机构
[1] Department of Surgery,
[2] Orthopedic Unit,undefined
[3] Department of Radiology,undefined
[4] Department of Medical Sciences,undefined
[5] University Hospital,undefined
[6] Uppsala,undefined
[7] Sweden,undefined
来源
Osteoporosis International | 2001年 / 12卷
关键词
Key words:DXA – Heel ultrasound – Hip fracture – Phalangeal ultrasonography – Radiographic absorptiometry;
D O I
暂无
中图分类号
学科分类号
摘要
Dual-energy X-ray absorptiometry (DXA) of the proximal femur and in more recent years quantitative ultrasound (QUS) of the heel are the most established methods for assessing hip fracture risk. Measurement of the fingers offers a new approach. We performed DXA of the proximal femur, QUS of the heel and fingers, and radiographic absorptiometry (RA) of the fingers in 87 non-institutionalized women, 65–85 years of age, with a first hip fracture and compared them with 195 randomly selected age-matched controls. Bone mineral density (BMD) of the femoral neck and heel Stiffness Index were significantly lower among cases than among controls (by 15% and 17%, respectively; p<0.0001), whereas no significant differences were found for finger measurements. When applying the WHO criterion of osteoporosis, 62–98% of the patients were classified as osteoporotic, compared with 19–85% of the controls, depending on method and site. The risks of hip fracture, estimated as odds ratios for every 1 SD reduction in femoral neck BMD, heel Stiffness Index, finger QUS and finger RA, were: 3.6 (95% CI 2.4–5.5), 3.4 (95% CI 2.2–5.0), 1.0 (95% CI 0.7–1.3) and 1.2 (95% CI 0.8–1.6), respectively. Compared with women with normal BMD of the femoral neck, those classified as osteopenic had an odds ratio of hip fracture of 14 (95% CI 2-110), whereas those classified as osteoporotic had an odds ratio of 63 (95% CI 8–501). We conclude that hip DXA and heel QUS have similar capacities to discriminate the risk of a first hip fracture, whereas QUS and RA of the phalanges seem inferior techniques for differentiating female hip fracture patients from controls.
引用
收藏
页码:185 / 191
页数:6
相关论文
共 13 条
  • [1] DXA of the hip and heel ultrasound but not densitometry of the fingers can discriminate female hip fracture patients from controls:: A comparison between four different methods
    Ekman, A
    Michaëlsson, K
    Petrén-Mallmin, M
    Ljunghall, S
    Mallmin, H
    OSTEOPOROSIS INTERNATIONAL, 2001, 12 (03) : 185 - 191
  • [2] Measurements with DXA of the hip and heel ultrasound but not densitometry of the fingers predict a first hip fracture. A comparison between four different methods.
    Ekman, A
    Mallmin, H
    PetrenMallmin, M
    Ljunghall, S
    JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 : 113 - 113
  • [3] Dual X-ray absorptiometry of hip, heel ultrasound, and densitometry of fingers can discriminate male patients with hip fracture from control subjects -: A comparison of four different methods
    Ekman, A
    Michaëlsson, K
    Petrén-Mallmin, M
    Ljunghall, S
    Mallmin, H
    JOURNAL OF CLINICAL DENSITOMETRY, 2002, 5 (01) : 79 - 85
  • [4] DXA and QUS can comparably discriminate patients with osteoporotic hip fracture from matched controls
    Hadji, P
    Esser, G
    Schnabel, M
    Mann, D
    Wagner, U
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 : S44 - S45
  • [5] DXA AND QUS ARE EQUALLY GOOD IN DISCRIMINATING OSTEOPOROTIC HIP FRACTURE PATIENTS FROM MATCHED CONTROLS
    Hadji, P.
    Esser, G.
    Schnabel, M.
    Mann, D.
    Bauer, M.
    Wagner, U.
    CALCIFIED TISSUE INTERNATIONAL, 2004, 74 : S92 - S92
  • [6] DXA and QUS can comparably dicriminate patients with osteoporotic hip fractures from matched controls
    Hadji, P
    Gottschalk, M
    Ziller, V
    Mann, E
    Esser, G
    Wagner, U
    JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 : S364 - S364
  • [7] Ultrasound of the phalanges is not related to a previous fracture -: A comparison between ultrasound of the phalanges, calcaneus, and DXA of the spine and hip in 75-year-old women
    Gerdhem, P
    Magnusson, H
    Karlsson, MK
    Åkesson, K
    JOURNAL OF CLINICAL DENSITOMETRY, 2002, 5 (02) : 159 - 166
  • [8] Examining Differences in Recovery Outcomes between Male and Female Hip Fracture Patients: Design and Baseline Results of A Prospective Cohort Study from the Baltimore Hip Studies
    Orwig D.
    Hochberg M.C.
    Gruber-Baldini A.L.
    Resnick B.
    Miller R.R.
    Hicks G.E.
    Cappola A.R.
    Shardell M.
    Sterling R.
    Hebel J.R.
    Johnson R.
    Magaziner J.
    The Journal of Frailty & Aging, 2018, 7 (3) : 162 - 169
  • [9] A comparison of outcomes between Canada and the United States in patients recovering from hip fracture repair: secondary analysis of the FOCUS trial
    Beaupre, Lauren A.
    Wai, Eugene K.
    Hoover, Donald R.
    Noveck, Helaine
    Roffey, Darren M.
    Cook, Donald R.
    Magaziner, Jay S.
    Carson, Jeffrey L.
    INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2018, 30 (02) : 97 - 103
  • [10] Differences in body composition between female geriatric hip fracture patients and healthy controls: Body fat is more important as explanatory factor for the fracture than body weight and lean body mass
    Galvard, H
    Elmstahl, S
    Elmstahl, B
    Samuelsson, SM
    Robertsson, E
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 1996, 8 (04) : 282 - 286