Three-Dimensional Modelling of the Middle-Ear Ossicular Chain Using a Commercial High-Resolution X-Ray CT Scanner

被引:0
|
作者
W. F. Decraemer
J. J. J. Dirckx
W. R. J. Funnell
机构
[1] University of Antwerp,Biomedical Physics
[2] RUCA,undefined
[3] Antwerpen,undefined
[4] McGill University,undefined
[5] Montréal,undefined
[6] Québec,undefined
关键词
three-dimensional; middle-ear; models; X-ray; computer; tomography;
D O I
暂无
中图分类号
学科分类号
摘要
The quantitative measurement of the three-dimensional (3-D) anatomy of the ear is of great importance in the making of teaching models and the design of mathematical models of parts of the ear, and also for the interpretation and presentation of experimental results. This article describes how we used virtual sections from a commercial high-resolution X-ray computed tomography (CT) scanner to make realistic 3-D anatomical models for various applications in our middle-ear research. The important problem of registration of the 3-D model within the experimental reference frame is discussed. The commercial X-ray CT apparatus is also compared with X-ray CT using synchrotron radiation, with magnetic resonance microscopy, with fluorescence optical sectioning, and with physical (histological) serial sections.
引用
收藏
页码:250 / 263
页数:13
相关论文
共 50 条
  • [1] Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner
    Decraemer, WF
    Dirckx, JJJ
    Funnell, WRJ
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2003, 4 (02): : 250 - 263
  • [2] DIAGNOSIS OF THE OSSICULAR CHAIN IN THE MIDDLE-EAR BY HIGH-RESOLUTION CT
    FUSE, T
    AOYAGI, M
    KOIKE, Y
    SUGAI, Y
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1992, 54 (05): : 251 - 254
  • [3] High-Resolution Three-Dimensional X-Ray Microscopy
    Bennett C. Larson
    Bruno Lengeler
    MRS Bulletin, 2004, 29 : 152 - 156
  • [4] High-resolution three-dimensional x-ray microscopy
    Larson, BC
    Lengeler, B
    MRS BULLETIN, 2004, 29 (03) : 152 - 154
  • [5] HIGH-RESOLUTION CT IN THE DIAGNOSIS OF MIDDLE-EAR DISORDERS
    GREVERS, G
    VOGL, T
    KANG, K
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1988, 245 (06): : 390 - 390
  • [6] HR (HIGH-RESOLUTION) CT IN MALFORMATION OF THE MIDDLE-EAR
    GREVERS, G
    VOGL, T
    MARKL, A
    KANG, K
    LARYNGO-RHINO-OTOLOGIE, 1989, 68 (02) : 88 - 91
  • [7] Three-dimensional imaging of arrays of fluid inclusions in fluorite by high-resolution X-ray CT
    Nakashima, Y
    Hirai, H
    Koishikawa, A
    Ohtani, T
    NEUES JAHRBUCH FUR MINERALOGIE-MONATSHEFTE, 1997, (12): : 559 - 568
  • [8] Three-dimensional imaging of arrays of fluid inclusions in fluorite by high-resolution X-ray CT
    Nakashima, Y.
    Hirai, H.
    Koishikawa, A.
    Ohtani, T.
    Neues Jahrbuch fuer Mineralogie. Monatshefte, (12):
  • [9] Three-dimensional grain fabric measurements using high-resolution X-ray computed tomography
    Ketcham, RA
    JOURNAL OF STRUCTURAL GEOLOGY, 2005, 27 (07) : 1217 - 1228
  • [10] Three-dimensional analysis of plant structure using high-resolution X-ray computed tomography
    Stuppy, WH
    Maisano, JA
    Colbert, MW
    Rudall, PJ
    Rowe, TB
    TRENDS IN PLANT SCIENCE, 2003, 8 (01) : 2 - 6