Dipolar and quadrupolar detection using an FT-ICR MS setup at the MPIK Heidelberg

被引:0
|
作者
Michael Heck
Klaus Blaum
R. Burcu Cakirli
Daniel Rodríguez
Lutz Schweikhard
Stefan Stahl
Marta Ubieto-Díaz
机构
[1] Max-Planck-Insitute for Nuclear Physics,Department of Physics
[2] University of Istanbul,Institute of Physics
[3] Universidad de Granada,undefined
[4] Ernst-Moritz-Arndt University Greifswald,undefined
[5] Stahl-Electronics,undefined
来源
Hyperfine Interactions | 2011年 / 199卷
关键词
Penning traps; FT-ICR MS; Detection methods; High resolution mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
Dipolar and single-phase two-electrode quadrupolar detection schemes have been investigated at a Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) setup built for the KATRIN experiment at the Max-Planck-Institute for Nuclear Physics (MPIK) in Heidelberg. We present first experimental results of 7Li +  signals from a cylindrical Penning trap configuration for both detection schemes. While the prominent signal of the conventional dipolar detection scheme marks the reduced cyclotron frequency, the main signal for the quadrupolar detection appears at the sum of the reduced cyclotron frequency and the magnetron frequency. For ideal trapping fields, this sum frequency equals the ion cyclotron frequency νc = qB/(2πm). Sidebands due to the combined motions of the cyclotron mode and magnetron mode are observed by quadrupolar detection which allows the determination of the respective combinations of eigenfrequencies.
引用
收藏
页码:347 / 355
页数:8
相关论文
共 50 条
  • [1] Dipolar and quadrupolar detection using an FT-ICR MS setup at the MPIK Heidelberg
    Heck, Michael
    Blaum, Klaus
    Cakirli, R. Burcu
    Rodriguez, Daniel
    Schweikhard, Lutz
    Stahl, Stefan
    Ubieto-Diaz, Marta
    HYPERFINE INTERACTIONS, 2011, 199 (1-3): : 347 - 355
  • [2] Narrow Aperture Detection Electrodes ICR Cell with Quadrupolar Ion Detection for FT-ICR MS at the Cyclotron Frequency
    Nagornov, Konstantin O.
    Kozhinov, Anton N.
    Nicol, Edith
    Tsybin, Oleg Yu
    Touboul, David
    Brunelle, Alain
    Tsybin, Yury O.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (11) : 2258 - 2269
  • [3] Metabolic profiling analysis using FT-ICR MS
    Oikawa, A
    Kimura, A
    Nakamura, Y
    Sakurai, N
    Suzuki, H
    Saito, K
    Shibata, D
    Kanaya, S
    Ohta, D
    PLANT AND CELL PHYSIOLOGY, 2006, 47 : S24 - S24
  • [4] Petroleomics by EASI(±) FT-ICR MS
    Corilo, Yuri E.
    Vaz, Boniek G.
    Simas, Rosineide C.
    Lopes Nascimento, Heliara D.
    Klitzke, Clecio F.
    Pereira, Rosana C. L.
    Bastos, Wagner L.
    Santos Neto, Eugenio V.
    Rodgers, Ryan P.
    Eberlin, Marcos N.
    ANALYTICAL CHEMISTRY, 2010, 82 (10) : 3990 - 3996
  • [5] AVERAGING METHODS APPLIED TO QUADRUPOLAR FT-ICR PERTURBATION PROBLEMS
    MITCHELL, DW
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 107 (03): : 417 - 434
  • [6] CHARACTERIZATION OF VACUUM GAS OILS USING FT-ICR MS
    Gomez-Escudero, Andrea
    Rojas-Ruiz, Fernando-Andres
    Orrego-Ruiz, Jorge-Armando
    CT&F-CIENCIA TECNOLOGIA Y FUTURO, 2015, 6 (01): : 69 - 80
  • [7] Metabolic Fingerprinting in Toxicological Assessment Using FT-ICR MS
    Hasegawa, Mina
    Ide, Mika
    Kuwamura, Mitsuru
    Yamate, Jyoji
    Takenaka, Shigeo
    JOURNAL OF TOXICOLOGIC PATHOLOGY, 2010, 23 (02) : 67 - 74
  • [8] Analysis of amino acid isotopomers using FT-ICR MS
    Pingitore, Francesco
    Tang, Yinjie
    Kruppa, Gary H.
    Keasling, Jay D.
    ANALYTICAL CHEMISTRY, 2007, 79 (06) : 2483 - 2490
  • [9] Application of FT-ICR MS Equipped with Quadrupole Detection for Analysis of Crude Oil
    Cho, Eunji
    Witt, Matthias
    Hur, Manhoi
    Jung, Maeng-Joon
    Kim, Sunghwan
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12101 - 12107
  • [10] Characterization of petroleum samples by GC/FT-ICR MS
    Solouki, Touradj
    Rasaiah, Jayendran C.
    Szulejko, J. E.
    Silwal, Indira K.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238