The diagnostic value of colour duplex ultrasound for symptomatic carotid stenosis in clinical practice

被引:0
|
作者
D. W. J. Dippel
A. de Kinkelder
S. L. M. Bakker
F. van Kooten
H. van Overhagen
P. J. Koudstaal
机构
[1] Dept of Neurology,
[2] University Hospital Dijkzigt,undefined
[3] PO Box 2040,undefined
[4] 3000 CA Rotterdam,undefined
[5] The Netherlands E-mail: dippel@neuro.fgg.eur.nl Tel.: +31-10-4 63 92 22 Fax: +31-10-4 36 72 93,undefined
[6] Department of Radiology,undefined
[7] University Hospital Dijkzigt,undefined
[8] Rotterdam,undefined
[9] The Netherlands,undefined
来源
Neuroradiology | 1999年 / 41卷
关键词
Key words Ultrasonography; duplex; Doppler; Cerebral ischaemia; carotid artery disease;
D O I
暂无
中图分类号
学科分类号
摘要
We assessed the accuracy of colour duplex ultrasound for the detection of severe (70–99 %) symptomatic carotid stenosis in a clinical setting, in order to assess whether it could make carotid angiography unnecessary. In 152 patients with a transient ischaemic attack or non-disabling ischaemic stroke in the carotid distribution, we compared the degree of colour duplex ultrasound stenosis with angiographic stenosis by receiver-operating-characteristic analysis. The angiograms were evaluated by blinded observers, and compared with routine reports of the colour duplex examination. We computed the sensitivity and specificity of colour duplex, and the number of angiograms and sonographic studies needed to prevent one stroke within 3 years, taking into account the risks of angiography, and the risks and efficacy of endarterectomy. The estimates were adjusted for nonverification bias. We found 34 patients (22 %) with a severe (70–99 %) symptomatic carotid stenosis. In 16 patients (11 %) the symptomatic artery was occluded. The sensitivity and specificity of duplex ultrasound were 76 % and 85 %, respectively. The number of patients needed to undergo angiography to prevent one stroke was reduced from almost 200 to 33, when colour duplex was used as a preoperative examination. After adjustment for the effects of nonverification, the sensitivity dropped to 58 % and the number of duplex studies needed to prevent one stroke would double. The number of angiograms needed after positive duplex sonography would be virtually unaffected. Were colour duplex sonography to have been the sole preoperative investigation, the number needed to diagnose to prevent one stroke within 3 years would be approximately 350, more than twice as many as with the combined diagnostic strategy. The diagnostic accuracy of colour duplex sonography in clinical practice seems less impressive than previous studies have suggested, but it remains an effective way to select patients for angiography. Its use as a single preoperative assessment cannot be recommended.
引用
收藏
页码:1 / 8
页数:7
相关论文
共 50 条
  • [1] The diagnostic value of colour duplex ultrasound for symptomatic carotid stenosis in clinical practice
    Dippel, DWJ
    de Kinkelder, A
    Bakker, SLM
    van Kooten, F
    van Overhagen, H
    Koudstaal, PJ
    NEURORADIOLOGY, 1999, 41 (01) : 1 - 8
  • [2] Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments
    Cassola, Nicolle
    Baptista-Silva, Jose C. C.
    Nakano, Luis C. U.
    Flumignan, Carolina D. Q.
    Sesso, Ricardo
    Vasconcelos, Vladimir
    Junior, Nelson Carvas
    Flumignan, Ronald L. G.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2022, (07):
  • [3] New duplex ultrasound scan criteria for managing symptomatic 50% or greater carotid stenosis
    Winkelaar, GB
    Chen, JC
    Salvian, AJ
    Taylor, DC
    Teal, PA
    Hsiang, YN
    JOURNAL OF VASCULAR SURGERY, 1999, 29 (06) : 986 - 993
  • [4] DUPLEX ACCURACY COMPARED TO ANGIOGRAPHY IN SYMPTOMATIC CAROTID STENOSIS
    不详
    STROKE, 1992, 23 (01) : 142 - 142
  • [5] THE PROGNOSIS OF SYMPTOMATIC CAROTID-ARTERY STENOSIS - A CLINICAL AND ULTRASOUND STUDY
    BERLIT, P
    HOCKER, A
    JASCHKE, W
    NERVENHEILKUNDE, 1990, 9 (04) : 145 - 149
  • [6] Turbulence in Carotid Stenosis by Duplex Ultrasound Imaging
    Koons, Katelyn
    Glaser, Julia D.
    Sehgal, Chandra
    Davis, Julia
    Foley, Paul
    Wang, Grace J.
    Fairman, Ronald M.
    Jackson, Benjamin M.
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 85S - 86S
  • [7] New duplex ultrasound scan criteria for managing symptomatic 50% or greater carotid stenosis - Discussion
    O'Donnell, T
    Winkelaar, G
    Kent, KC
    Cronenwett, J
    Hopkins, R
    JOURNAL OF VASCULAR SURGERY, 1999, 29 (06) : 993 - 994
  • [8] Duplex ultrasound: A diagnostic tool for carotid stenosis management in type 2 diabetes mellitus
    Kisten, Yogan
    Govender, Pravesen
    Naidoo, Nadraj G.
    Gihwala, Dhiro
    Isaacs, Ferial
    AFRICAN JOURNAL OF PRIMARY HEALTH CARE & FAMILY MEDICINE, 2013, 5 (01) : 1 - 6
  • [9] Comparison of Two Duplex Ultrasound Diagnostic Criteria for Carotid Stenosis With Computed Tomography Angiography
    Kim, Ann H.
    Augustin, Gener
    Kim, Hannah
    Shevitz, Andrew J.
    Morrow, Katherine L.
    Trivonovich, Michael R.
    Powell, Alexis R.
    Tarr, Robert
    Kashyap, Vikram S.
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (03) : 864 - 865
  • [10] Clinical Value of CTA in Patients with ≥50% ICA Stenosis by Duplex Ultrasound
    ElSorady, Mohammad I.
    Hall, Heather
    Bernhard, Vector
    Bassiouny, Hisham
    JOURNAL OF VASCULAR SURGERY, 2011, 53 : 8S - 8S