Reduction of Fringe Noise in Wavelength Modulation Spectroscopy Using a One-Dimensional Focal Plane Array

被引:3
|
作者
Shang-Qian Wu
Tetsuya Kimishima
Yotsumi Yoshii
Hiroaki Kuze
Nobuo Takeuchi
机构
[1] Nippon Sanso Corporation,Tsukuba Laboratories
[2] Chiba University,Center for Environmental Remote Sensing
来源
Optical Review | 2002年 / 9卷
关键词
diode laser; molecular spectra; wavelength modulation; focal plane array; fringe noise;
D O I
暂无
中图分类号
学科分类号
摘要
In wavelength modulation spectroscopy using diode lasers, detection limit of molecular absorption is often imposed by spurious fringe noises that arise from slight reflections among optical components. In an attempt to reduce this fringe effect, we propose and demonstrate the use of a one-dimensional focal plane array. With the help of a multiplexer, a single lock-in amplifier is employed to obtain multiple-channel signals from wavelength-modulated output of an array detector. It is found that the intensity change of the molecular absorption signal is nearly proportional to the transversal beam intensity distribution, whereas that of fringe noise is much less conspicuous. These features, as well as the phase difference among the channels, contribute to separate the signal and fringe noise components from the multiplexed spectra, leading to the overall improvement in the signal-to-noise ratio.
引用
收藏
页码:189 / 192
页数:3
相关论文
共 50 条
  • [1] Reduction of fringe noise in wavelength modulation spectroscopy using a one-diniensional focal plane array
    Wu, SQ
    Kimishima, T
    Yoshii, Y
    Kuze, H
    Takeuchi, N
    OPTICAL REVIEW, 2002, 9 (05) : 189 - 192
  • [2] Reconstructed x-ray for a one-dimensional translation of an area focal plane array
    Halama, G
    McAdoo, J
    Liu, H
    BIOMEDICAL SENSING, IMAGING, AND TRACKING TECHNOLOGIES I, 1996, 2676 : 112 - 115
  • [3] A one-dimensional CMOS focal plane array for Gabor-type image filtering
    Shi, BE
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 1999, 46 (02) : 323 - 327
  • [4] Mass spectrum measurement using a one-dimensional focal plane detector
    Birkinshaw, K
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 215 (1-3) : 195 - 209
  • [5] Reduction of Fringe Noise in a Multi-pass Absorption Cell by Using the Wavelength Modulation Technique
    Lee, Lim
    Park, Hyunmin
    Ko, Kwang-Hoon
    Kim, Taek-Soo
    Jeong, Do-Young
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 57 (02) : 364 - 368
  • [6] The Effect of Contact Resistance on Short Wavelength Infrared Focal Plane Array Noise
    Piquette, E. C.
    JOURNAL OF ELECTRONIC MATERIALS, 2024, 53 (10) : 5858 - 5864
  • [7] TRACKING BACTERIAL MOVEMENTS USING A ONE-DIMENSIONAL FRINGE SYSTEM
    HOLZ, M
    CHEN, SH
    OPTICS LETTERS, 1978, 2 (05) : 109 - 111
  • [8] WAVELENGTH SELECTION AND TRANSIENTS IN THE ONE-DIMENSIONAL ARRAY OF CELLS OF THE PRINTER INSTABILITY
    RABAUD, M
    COUDER, Y
    MICHALLAND, S
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 1991, 10 (02) : 253 - 260
  • [9] Two-dimensional beam-steering with wavelength control using one-dimensional optical phased array
    Yoon, Hyeonho
    Rhee, Hyun-Woo
    Kwon, Nam-Hyun
    Kim, Jaeyong
    Kim, Junhyeong
    Yoon, Jinhyeong
    Fasih, Muhammad
    Park, Hyo-Hoon
    SILICON PHOTONICS XVII, 2022, 12006
  • [10] The signal-to-noise ratio analysis of coronal plane microwave correlation imaging based on azimuth one-dimensional array
    Yu, Xiaoxu
    Li, Dechun
    Du, Liuge
    Chu, Hongwei
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2020, 34 (01) : 129 - 139