In Situ Femoral Dual-Energy X-ray Absorptiometry Related to Ash Weight, Bone Size and Density, and its Relationship with Mechanical Failure Loads of the Proximal Femur

被引:0
|
作者
E.-M. Lochmüller
P. Miller
D. Bürklein
U. Wehr
W. Rambeck
F. Eckstein
机构
[1] I. Frauenklinik des Klinikums der Ludwig-Maximilians-Universität München,
[2] Munich,undefined
[3] Institut für Physiologie,undefined
[4] Physiologische Chemie und Tieremährung der Ludwig-Maximilians-Universität München,undefined
[5] Munich,undefined
[6] ,undefined
[7] Musculoskeletal Research Group,undefined
[8] Institute of Anatomy,undefined
[9] Ludwig-Maximilians-Universität München,undefined
[10] Munich,undefined
[11] Germany,undefined
来源
关键词
Key words:Ash weight – Bone density – Bone size – DXA – Mechanical failure – Proximal femur;
D O I
暂无
中图分类号
学科分类号
摘要
The objective of this study was to directly compare in situ femoral dual-energy X-ray absorptiometry (DXA) and in vitro chemical analysis (ash weight and calcium) with mechanical failure loads of the proximal femur, and to determine the influence of bone size (volume) and density on mechanical failure and DXA-derived areal bone mineral density (BMD, in g/cm2). We performed femoral DXA in 52 fixed cadavers (age 82.1 ± 9.7 years; 30 male, 22 female) with intact skin and soft tissues. The femora were then excised, mechanically loaded to failure in a stance phase configuration, their volume measured with a water displacement method (proximal neck to lesser trochanter), and the ash weight and calcium content of this region determined by chemical analysis. The correlation coefficient between the bone mineral content (measured in situ with DXA) and the ash weight was r= 0.87 (standard error of the estimate = 16%), the ash weight allowing for a better prediction of femoral failure loads (r= 0.78; p<0.01) than DXA (r= 0.67; p<0.01). The femoral volume (r= 0.61; p<0.01), but not the volumetric bone density (r= 0.26), was significantly associated with the failure load. The femoral bone volume had a significant impact (r= 0.35; p< 0.01) on the areal BMD (DXA), and only 63% of the variability of bone volume could be predicted (based on the basis of body height, weight and femoral projectional bone area. The results suggest that accuracy errors of femoral DXA limit the prediction of mechanical failure loads, and that the influence of bone size on areal BMD cannot be fully corrected by accounting for body height, weight and projected femoral area.
引用
收藏
页码:361 / 367
页数:6
相关论文
共 50 条
  • [1] In situ femoral dual-energy X-ray absorptiometry related to ash weight, bone size and density, and its relationship with mechanical failure loads of the proximal femur
    Lochmüller, EM
    Miller, P
    Bürklein, D
    Wehr, U
    Rambeck, W
    Eckstein, F
    [J]. OSTEOPOROSIS INTERNATIONAL, 2000, 11 (04) : 361 - 367
  • [2] The correlation between dual-energy X-ray absorptiometry measures of bone density in the proximal femur and lumbar spine of children
    Henderson, RC
    [J]. SKELETAL RADIOLOGY, 1997, 26 (09) : 544 - 547
  • [3] PREMENOPAUSAL AND POSTMENOPAUSAL CHANGES IN BONE-MINERAL DENSITY OF THE PROXIMAL FEMUR MEASURED BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    RAVN, P
    HETLAND, ML
    OVERGAARD, K
    CHRISTIANSEN, C
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1994, 9 (12) : 1975 - 1980
  • [4] The correlation between dual-energy X-ray absorptiometry measures of bone density in the proximal femur and lumbar spine of children
    Richard C. Henderson
    [J]. Skeletal Radiology, 1997, 26 : 544 - 547
  • [5] Dual-energy X-ray absorptiometry and bone density measurement
    Jonsson, K.
    [J]. ACTA RADIOLOGICA, 2007, 48 (02) : 123 - 123
  • [6] A Long Femur Scan Field Does Not Alter Proximal Femur Bone Mineral Density Measurements by Dual-Energy X-Ray Absorptiometry
    McKiernan, Fergus Eoin
    Hocking, Jane
    Cournoyer, Susan
    Berg, Richard L.
    Linneman, James
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2011, 14 (03) : 354 - 358
  • [7] The contribution of cortical and cancellous bone to dual-energy X-ray absorptiometry measurements in the female proximal femur
    Lundeen, GA
    Knecht, SL
    Vajda, EG
    Bloebaum, RD
    Hofmann, AA
    [J]. OSTEOPOROSIS INTERNATIONAL, 2001, 12 (03) : 192 - 198
  • [8] The Contribution of Cortical and Cancellous Bone to Dual-Energy X-ray Absorptiometry Measurements in the Female Proximal Femur
    G. A. Lundeen
    S. L. Knecht
    E. G. Vajda
    R. D. Bloebaum
    A. A. Hofmann
    [J]. Osteoporosis International, 2001, 12 : 192 - 198
  • [9] Measurements and Evaluation of Proximal Femoral Bone Mineral Density with Dual Energy X-ray Absorptiometry
    Hayashida, Keiichi
    Takeda, Yoshihiro
    Katsuda, Toshizo
    Yamamoto, Kenyu
    Suesada, Yasuhide
    Shibata, Moeko
    Azuma, Masami
    [J]. ACTA MEDICA OKAYAMA, 2012, 66 (01) : 17 - 21
  • [10] EFFECT OF SCOLIOSIS ON SPINAL AND FEMORAL BONE-DENSITY BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    KIM, JK
    BOSCH, E
    EDELSTEIN, S
    BARRETTCONNOR, E
    SARTORIS, DJ
    [J]. RADIOLOGY, 1992, 185 : 266 - 266