Anisotropy measurement of pyrolytic carbon layers of coated particles

被引:0
|
作者
Ju. A. Vesyolkin
A. S. Ivanov
T. V. Trushkina
机构
[1] National Research Center Kurchatov Institute,
[2] All-Russia Research Institute of Inorganic Materials (VNIINM),undefined
来源
Physics of Atomic Nuclei | 2015年 / 78卷
关键词
microfuel; pyrolytic carbon; anisotropy; layers; measurement error;
D O I
暂无
中图分类号
学科分类号
摘要
Equipment at the National Research Center Kurchatov Institute intended for the anisotropy determination of pyrolytic carbon layers in coated particles (CPs) of the GT-MGR reactor is tested and calibrated. The dependence of the anisotropy coefficient on the size of the measurement region is investigated. The results of measuring the optical anisotropy factor (OPTAF) for an aluminum mirror, rutile crystal, and available CP samples with the known characteristics measured previously using ORNL equipment (United States) are presented. In addition, measurements of CP samples prepared at VNIINM are performed. A strong dependence of the data on the preparation quality of metallographic sections is found. Our investigations allow us to make the conclusion on the working capacity of the existing equipment for measuring the anisotropy of pyrolytic carbon CP coatings using the equipment at the Kurchatov Institute with the relative error of about 1%. It is shown that the elimination of the errors caused by the stochastic fluctuations in a measuring path by mathematical processing of the signal allows us to decrease the relative error of OPTAF measurements to ~0.3%.
引用
收藏
页码:1309 / 1317
页数:8
相关论文
共 50 条