A comparison of micro-CT and histomorphometry for evaluation of osseointegration of PEO-coated titanium implants in a rat model

被引:0
|
作者
Tao He
Cong Cao
Zhiguo Xu
Gen Li
Huiliang Cao
Xuanyong Liu
Chao Zhang
Yuqi Dong
机构
[1] Department of Orthopedics,
[2] Ren Ji Hospital,undefined
[3] School of Medicine,undefined
[4] Shanghai Jiao Tong University,undefined
[5] State Key Laboratory of High Performance Ceramics and Superfine Microstructure,undefined
[6] Shanghai Institute of Ceramics,undefined
[7] Chinese Academy of Sciences,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The aim of the present study was to determine the correlation between bone volume density (BV/TV) around a titanium implant determined by micro-computed tomography (micro-CT) and bone area density (BA/TA) measurements obtained using histomorphometry. An intramedullary rat femur implant model was evaluated to compare raw titanium implants with plasma electrolytic oxidation (PEO)-coated titanium implants. Titanium and PEO-treated titanium pins were inserted into rat femurs under general anesthesia. The animals were sacrificed and femurs harvested at 0, 2, 4 and 6 weeks, and subsequently, histomorphometry and micro-CT were performed. BV/TV and BA/TA values were strongly and positively correlated at all time points and locations (with all correlation coefficients being >0.8 and with P < 0.001). BV/TV and BA/TA were significantly higher proximal to the growth plate than distal to the growth plate, with estimated differences of 14.10% (P < 0.001) and 11.95% (P < 0.001), respectively. BV/TV and BA/TA were significantly higher on the PEO-coated surface than on the raw titanium surface, with estimated differences of 3.20% (P = 0.044) and 4.10% (P = 0.018), respectively. Therefore, quantitative micro-CT analysis of BV/TV is correlated with BA/TA determined by histomorphometry when artifacts around titanium implants are minimized by a region of interest modification.
引用
收藏
相关论文
共 50 条
  • [1] A comparison of micro-CT and histomorphometry for evaluation of osseointegration of PEO-coated titanium implants in a rat model
    He, Tao
    Cao, Cong
    Xu, Zhiguo
    Li, Gen
    Cao, Huiliang
    Liu, Xuanyong
    Zhang, Chao
    Dong, Yuqi
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [2] Evaluation of Osseointegration of Titanium Alloyed Implants: A Comparison of Micro-computed Tomography and Histomorphometry
    Gabler, Carolin
    Zietz, Carmen
    Bieck, Richard
    Goehler, Rebecca
    Bader, Rainer
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S1132 - S1132
  • [3] Osseointegration of titanium dental implant under fluoride exposure in rabbits: Micro-CT and histomorphometry study
    Yu, Ying-juan
    Zhu, Wen-qing
    Xu, Li-na
    Ming, Pan-pan
    Shao, Shui-yi
    Qiu, Jing
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (10) : 1038 - 1048
  • [4] Osseointegration of Tantalum Trabecular Metal in Titanium Dental Implants: Histological and Micro-CT Study
    Al Deeb, Modhi
    Aldosari, Abdullah AlFarraj
    Anil, Sukumaran
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (07)
  • [5] A comparison of micro-CT, microradiography and histomorphometry in bone research
    Gielkens, Pepijn F. M.
    Schortinghuis, Jurjen
    de Jong, Johan R.
    Huysmans, Marie Charlotte D. N. J. M.
    van Leeuwen, M. Barbara M.
    Raghoebar, Gerry M.
    Bos, Ruud R. M.
    Stegenga, Boudewijn
    [J]. ARCHIVES OF ORAL BIOLOGY, 2008, 53 (06) : 558 - 566
  • [6] Osseointegration of zirconia implants with 3 varying surface textures and a titanium implant: A histological and micro-CT study
    Kubasiewicz-Ross, Pawel
    Hadzik, Jakub
    Dominiak, Marzena
    [J]. ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 27 (09): : 1173 - 1179
  • [7] Correlation between two-dimensional micro-CT and histomorphometry for assessment of the implant osseointegration in rabbit tibia model
    Hao-Zhen Lyu
    Jae Hyup Lee
    [J]. Biomaterials Research, 25
  • [8] Correlation between two-dimensional micro-CT and histomorphometry for assessment of the implant osseointegration in rabbit tibia model
    Lyu, Hao-Zhen
    Lee, Jae Hyup
    [J]. BIOMATERIALS RESEARCH, 2021, 25 (01)
  • [9] Modeling of Biological Activity of PEO-Coated Titanium Implants with Conjugates of Cyclic RGD Peptide with Amino Acid Bisphosphonates
    Parfenova, Lyudmila, V
    Galimshina, Zulfiya R.
    Gil'fanova, Guzel U.
    Alibaeva, Eliza, I
    Danilko, Ksenia, V
    Aubakirova, Veta R.
    Farrakhov, Ruzil G.
    Parfenov, Evgeny, V
    Valiev, Ruslan Z.
    [J]. MATERIALS, 2022, 15 (22)
  • [10] Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry
    Gabler, Carolin
    Zietz, Carmen
    Bieck, Richard
    Goehler, Rebecca
    Lindner, Tobias
    Haenle, Maximilian
    Finke, Birgit
    Meichsner, Juergen
    Testrich, Holger
    Nowottnick, Mathias
    Frerich, Bernhard
    Bader, Rainer
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015