Consideration of prosthesis-patient mismatch and left ventricular mass regression after implantation of the Carpentier-Edwards pericardial valve in elderly Japanese patients: Body surface area may be irrelevant

被引:0
|
作者
Takai H. [1 ]
Yamachika S. [1 ]
Hazama S. [1 ]
Ariyoshi T. [1 ]
Odate T. [1 ]
Matsukuma S. [1 ]
Yanatori M. [1 ]
Onohara D. [1 ]
Eishi K. [1 ]
机构
[1] Department of Cardiovascular Surgery, School of Medicine, Nagasaki University, Nagasaki 852-8501
关键词
Aortic valve replacement; Bioprosthesis; Cardiac surgery; Left ventricular mass regression; Prosthesis-patient mismatch;
D O I
10.1007/s10047-004-0270-z
中图分类号
学科分类号
摘要
The assessment of prosthesis patient mismatch (PPM) for small aortic annulus is important for prognosis after aortic valve replacement (AVR). Recent investigations have demonstrated that PPM occurs in AVR patients with an indexed effective orifice area (iEOA) of less than 0.85 cm2/m2. We investigated hemodynamic performance and left ventricular mass (LVM) regression after AVR. Eighteen patients who underwent AVR using a 19-mm Carpentier-Edwards pericardial (CEP) valve without annular enlargement were studied by echocardiography and Doppler examination 4 months after AVR. Patients were divided into two groups on the basis of their body surface area (BSA); the smaller BSA (group S, 1.14-1.36 m2, nine patients) and the larger BSA (group L, 1.40-1.83 m2, nine patients). Of these 18 patients, ten underwent isolated AVR, and five underwent AVR with coronary artery bypass graft; (i.e., double valvular replacement, AVR with maze procedure, and AVR with mitral valvulophasty. There were no statistically significant differences between the two groups, except for age (group S, 78.3 ± 2.5 years; group L, 73.6 ± 2.4 years). There was no significant difference for the iEOA during the late phase at rest (group S, 1.10 ± 0.26 cm2; group L, 1.02 ± 0.28 cm2). However, there was a significant difference for the LVM regression between the preoperative and postoperative values (group S, 243 ± 23.6 mg/cm2 [pre], 190 ± 16.9 mg/cm2 [post]; group L, 302 ± 13.7 mg/cm2 [pre], 199 ± 16.7 mg/cm2 [post]). In elderly Japanese patients with a BSA of less than 18 m2, we demonstrated LVM regression and avoidance of PPM after implantation of the aortic 19-mm CEP valve. © The Japanese Society for Artificial Organs 2004.
引用
收藏
页码:203 / 206
页数:3
相关论文
共 16 条
  • [1] Impact of aortic valve prosthesis-patient mismatch on left ventricular mass regression
    Ibrahim, Amr A.
    Attia, Mohamed
    Ammar, Ayman
    Hikal, Tamer
    EGYPTIAN JOURNAL OF SURGERY, 2024, 43 (03): : 965 - 972
  • [2] Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement
    Tasca, G
    Brunelli, F
    Cirillo, M
    DallaTomba, M
    Mhagna, Z
    Troise, G
    Quaini, E
    ANNALS OF THORACIC SURGERY, 2005, 79 (02): : 505 - 510
  • [3] Aortic valve replacement for aortic stenosis in the elderly: Influence of prosthesis-patient mismatch on late survival and left ventricular mass regression
    Kato Y.
    Tsutsumi Y.
    Kawai T.
    Goto T.
    Takahashi Y.
    Ohashi H.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (8) : 397 - 403
  • [4] Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis
    Kato, Yasuyuki
    Suehiro, Shigefumi
    Shibata, Toshihiko
    Sasaki, Yasuyuki
    Hirai, Hidekazu
    JOURNAL OF CARDIAC SURGERY, 2007, 22 (04) : 314 - 319
  • [5] Impact of valve prosthesis-patient mismatch on intermediate-term outcome and regression of left ventricular mass following aortic valve replacement with mechanical prosthesis
    Tao, Koji
    Sakata, Ryuzo
    Iguro, Yoshifumi
    Ueno, Masahiro
    Tanaka, Yasuhiro
    Otsuji, Yutaka
    Tei, Chuwa
    JOURNAL OF CARDIAC SURGERY, 2007, 22 (06) : 486 - 492
  • [6] Left ventricular mass regression in patients without patient–prosthesis mismatch after aortic valve replacement for aortic stenosis
    Kohei Hachiro
    Takeshi Kinoshita
    Tohru Asai
    Tomoaki Suzuki
    General Thoracic and Cardiovascular Surgery, 2020, 68 : 227 - 232
  • [7] Prosthesis-patient mismatch after transcatheter aortic valve implantation: prevalence and prognostic impact with respect to baseline left ventricular function
    Schofer, Niklas
    Deuschl, Florian
    Ruebsamen, Nicole
    Skibowski, Johanna
    Seiffert, Moritz
    Voigtlaender, Lisa
    Schaefer, Andreas
    Schneeberger, Yvonne
    Schirmer, Johannes
    Reichenspurner, Hermann
    Blankenberg, Stefan
    Conradi, Lenard
    Schafer, Ulrich
    EUROINTERVENTION, 2019, 14 (16) : 1648 - 1655
  • [8] Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: Effect on survival, freedom from heart failure, and left ventricular mass regression
    Ruel, M
    Al-Faleh, H
    Kulik, A
    Chan, KL
    Mesana, TG
    Burwash, IG
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05): : 1036 - 1044
  • [9] Left ventricular mass regression in patients without patient-prosthesis mismatch after aortic valve replacement for aortic stenosis
    Hachiro, Kohei
    Kinoshita, Takeshi
    Asai, Tohru
    Suzuki, Tomoaki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2020, 68 (03) : 227 - 232
  • [10] Effects of prosthesis-patient mismatch after aortic valve replacement on left ventricular function and remodeling in patients with normal and impaired preoperative left ventricular function
    Al-Faleh, H
    Ruel, M
    Chan, K
    Beauchesne, L
    Lam, B
    Mesana, T
    Burwash, I
    CIRCULATION, 2004, 110 (17) : 549 - 549