Comparison of compressive and splitting tensile strength of autoclaved aerated concrete (AAC) containing water hyacinth and polypropylene fibre subjected to elevated temperatures

被引:0
|
作者
Borvorn Israngkura Na Ayudhya
机构
[1] Rajamangala University of Technology Krungthep,Department of Civil Engineering
来源
Materials and Structures | 2016年 / 49卷
关键词
Autoclaved aerated concrete; Polypropylene fibre; Water hyacinth fibre; High temperature;
D O I
暂无
中图分类号
学科分类号
摘要
This paper described the results of an extensive experimental study on the comparative between compressive and splitting tensile behavior of autoclaved aerated concrete (AAC) containing water hyacinth fibre (WHF) with AAC mixed with polypropylene (PP) fibre. The specimens of AAC-WHF and the AAC-PP were subjected to elevated temperatures (100, 200, 400, 800 and 1000 °C). Test results indicated that an optimum water hyacinth and PP fibre dosage was at 0.5 and 0.75 % by volume respectively. The maximum residual in compressive strength and the splitting tensile strength of AAC-WHF and AAC-PP were 0.43 and 0.16 N/mm2 and 0.51 and 0.18 N/mm2 respectively. In addition, the loss in residual strength of AAC mixed PP fibre was slower than AAC mixed WHF. The splitting tensile strength of AACs was more sensitive to high temperatures than the compressive strength. A severe strength loss was observed for all of the AAC after exposure to 800 °C. Based on the test results, it can be concluded that the addition of PP fibers can significantly promote the residue mechanical properties of AAC during heating.
引用
收藏
页码:1455 / 1468
页数:13
相关论文
共 31 条
  • [2] Effects of polypropylene fibre on the compressive and splitting tensile strength of concrete
    Abdulwahab, Rasheed
    Akinleye, Tunde Monsuru
    Taiye, Hussein Sahid
    JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES, 2018, 5 (01): : 15 - 22
  • [3] Comparison of compressive and splitting tensile strength of high-strength concrete with and without polypropylene fibers heated to high temperatures
    Behnood, Ali
    Ghandehari, Masoud
    FIRE SAFETY JOURNAL, 2009, 44 (08) : 1015 - 1022
  • [4] Evaluation of ASTM methods to determine splitting tensile strength in concrete, masonry, and autoclaved aerated concrete
    Parker, Cody K.
    Tanner, Jennifer E.
    Varela, Jorge L.
    MASONRY, 2008, 1496 : 62 - +
  • [5] Splitting tensile behavior of autoclaved aerated concrete: Comparison of different specimens' results
    Malyszko, Leszek
    Kowalska, Edyta
    Bilko, Piotr
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 157 : 1190 - 1198
  • [6] Evaluation of ASTM methods to determine splitting tensile strength in concrete, masonry, and autoclaved aerated concrete
    Parker, Cody K.
    Tanner, Jennifer E.
    Varela, Jorge L.
    Journal of ASTM International, 2007, 4 (02):
  • [7] Fibre reinforced high strength concrete subjected to elevated temperatures
    Varona, Francisco de Borja
    Baeza, Francisco Javier
    Ivorra, Salvador
    Bru, David
    4TH INTERNATIONAL CONFERENCE ON MECHANICAL MODELS IN STRUCTURAL ENGINEERING (CMMOST 2017), 2017, : 653 - 666
  • [8] Examination of the relation between tensile/flexural strength and compressive strength of autoclaved aerated concrete according to prEN 12602
    Oettl, Christian
    Schellhorn, Hans
    ADVANCES IN CONSTRUCTION MATERIALS 2007, 2007, : 749 - +
  • [9] Effects of Compressive Strength of Concrete on RC Columns Subjected to Elevated Temperatures
    Krishna D.A.
    Priyadarsini R.S.
    Narayanan S.
    Journal of The Institution of Engineers (India): Series A, 2022, 103 (02) : 423 - 431
  • [10] Compressive strength and failure behaviour of fibre reinforced concrete at elevated temperatures
    Shaikh, F. U. A.