Enumeration of Legionella pneumophila in cooling tower water systems

被引:7
|
作者
Irfan Türetgen
Esra Ilhan Sungur
Aysin Cotuk
机构
[1] Istanbul University,Department of Biology, Faculty of Science
来源
关键词
aerosol; cooling tower; Legionnaires’ disease; risk assessment;
D O I
暂无
中图分类号
学科分类号
摘要
Legionella pneumophila, the causative agent of Legionnaires’ disease, is known to colonise and frequently grow in cooling tower waters. Disease is acquired by inhaling aerosol contaminated by legionellae. Determination of the count of Legionella pneumophila in cooling tower waters may, therefore, be useful for risk assessment. In our survey, 103 water samples from 50 cooling towers were examined over a five-year period to indicate the seasonal distribution and the ecology of L. pneumophila, as regards temperature and pH. L. pneumophila serogroup 1 was found in 44% of the isolated strains, which is primarily responsible for the majority of Legionnaires’ disease. The large majority of examined towers had levels of L. pneumophila in the high-risk category. These cooling towers have been linked to many outbreaks of Legionnaires’ disease.
引用
收藏
页码:53 / 58
页数:5
相关论文
共 50 条
  • [1] Enumeration of Legionella pneumophila in cooling tower water systems
    Türetgen, I
    Sungur, EI
    Cotuk, A
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2005, 100 (1-3) : 53 - 58
  • [2] Predictive Factors of Legionella pneumophila Contamination in Cooling Tower Water
    Luksamijarulkul, Pipat
    Kornkrerkkiat, Sumawadee
    Saranpuetti, Chayaporn
    Sujirarat, Dusit
    [J]. AIR SOIL AND WATER RESEARCH, 2014, 7 : 11 - 17
  • [3] Legionella pneumophila Risk from Cooling Tower Systems in China
    Qin, Tian
    Zhao, Dahui
    Zhu, Li
    Ren, Hongyu
    Li, Yinan
    Liu, Xinjun
    Li, Xiaopeng
    Li, Wei
    Zhao, Na
    Lu, Jiao
    Liu, Di
    Shi, Yi
    Fang, Min
    Duan, Xuefeng
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2022, 88 (03)
  • [4] Legionella pneumophila in an ammonia plant cooling tower
    Verduijn, WD
    [J]. PROCESS SAFETY PROGRESS, 2002, 21 (04) : 277 - 285
  • [5] The Impact of Storms on Legionella pneumophila in Cooling Tower Water, Implications for Human Health
    Brigmon, Robin L.
    Turick, Charles E.
    Knox, Anna S.
    Burckhalter, Courtney E.
    [J]. FRONTIERS IN MICROBIOLOGY, 2020, 11
  • [6] ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM COOLING-TOWER WATER BY FILTRATION
    ORRISON, LH
    CHERRY, WB
    MILAN, D
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1981, 41 (05) : 1202 - 1205
  • [7] Validation of MICA Legionella for Enumeration of Legionella pneumophila in Sanitary Waters and Cooling Tower Waters: AOAC Performance Tested MethodSM 032201
    Passot, Fanny
    Peslier, Sabine
    Benzinger Jr, M. Joseph
    Blackburn, Jonathan
    Thompson, Wesley
    Bastin, Benjamin
    Dumont, Audrey
    Dukan, Sam
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2023, 106 (03) : 725 - 736
  • [8] Prevalence of Legionella Cooling Tower Water Contamination and Legionella pneumophila Antibodies Among Hotel Workers of Jiangsu, China
    Sun, Hong
    Chen, Xiaodong
    [J]. EPIDEMIOLOGY, 2011, 22 (01) : S253 - S253
  • [9] EFFICACY OF METHYLCHLORO METHYLISOTHIAZOLONE BIOCIDE AGAINST LEGIONELLA-PNEUMOPHILA IN COOLING-TOWER WATER
    MCCOY, WF
    WIREMAN, JW
    LASHEN, ES
    [J]. JOURNAL OF INDUSTRIAL MICROBIOLOGY, 1986, 1 (01): : 49 - 56
  • [10] SUSCEPTIBILITIES OF ALGAE AND LEGIONELLA-PNEUMOPHILA TO COOLING-TOWER BIOCIDES
    SORACCO, RJ
    GILL, HK
    FLIERMANS, CB
    POPE, DH
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1983, 45 (04) : 1254 - 1260