Novel solid-phase extraction and preconcentration technique coupled with ICP-AES for the determination of Cr(III), Ni(II), and Zn(II) in various water samples

被引:0
|
作者
K. Suvardhan
K. Suresh Kumar
D. Rekha
K. Kiran
B. Jaya Raj
P. Chiranjeevi
机构
[1] S.V. University,Environmental Monitoring Laboratory, Department of Chemistry
[2] S.V. University,Department of Environmental Sciences
[3] S.V. University,Department of Mathematics
来源
关键词
Biosorption; Dithiocarbamate; Cloud Point Extraction; Natural Water Sample; Preconcentration Technique;
D O I
暂无
中图分类号
学科分类号
摘要
Newly synthesized 2-propylpiperidine-1-carbodithioate (2-PPC) was used for the extraction of Cr(III), Ni(II), and Zn(II) from various water samples. In the present investigation, the use of a syringe loaded with sorbent for the separation and enrichment of Cr(III), Ni(II), and Zn(II) prior to their determination by inductively coupled plasma-atomic emission spectrometry (ICP-AES) was proposed to substitute the batch and column techniques. The described method was compared with the column technique with respect to fastness, simplicity, recovery, and risk of contamination. The syringe was loaded with 1.0 g of sorbent in order to retain the analyte elements. Next, 7.0 mL of sample solution (pH 5.0 ± 0.2) was drawn into the syringe in 15 s and discharged over 15 s. Then, an eluent (3.0 M HCl) was drawn into the syringe and ejected back to desorb the analyte elements. At the optimum conditions, the percentage recoveries of Cr(III), Ni(II), and Zn(II) were in the range of 94.50 to 99.62% with a standard deviation (S.D.) of 0.03%. The elements could be concentrated by drawing and discharging several portions of sample successively and eluting only one time. The detailed study of various interferences proved the method to be highly selective. The risk of contamination is less than that with the column technique. The method was successfully applied to the determination of Cr(III), Ni(II), and Zn(II) in spiked and natural water samples. The results obtained are in good agreement with those obtained by the reported methods at the 95% confidence level.
引用
收藏
页码:336 / 341
页数:5
相关论文
共 50 条
  • [1] Novel solid-phase extraction and preconcentration technique coupled with ICP-AES for the determination of Cr(III), Ni(II), and Zn(II) in various water samples
    Suvardhan, K.
    Kumar, K. Suresh
    Rekha, D.
    Kiran, K.
    Raj, B. Jaya
    Chiranjeevi, P.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (04) : 336 - 341
  • [2] Preconcentration technique for the determination of trace elements in natural water samples by ICP-AES
    Babu, S. Hari
    Kumar, K. Suresh
    Suvardhan, K.
    Kiran, K.
    Rekha, D.
    Krishnaiah, L.
    Janardhanam, K.
    Chiranjeevi, P.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 128 (1-3) : 241 - 249
  • [3] Preconcentration technique for the determination of trace elements in natural water samples by ICP-AES
    S. Hari Babu
    K. Suresh Kumar
    K. Suvardhan
    K. Kiran
    D. Rekha
    L. Krishnaiah
    K. Janardhanam
    P. Chiranjeevi
    Environmental Monitoring and Assessment, 2007, 128 : 241 - 249
  • [4] Chemically modified silica gel with p-dimethylaminobenzaldehyde for selective solid-phase extraction and preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) by ICP-OES
    Cui, Yuemei
    Chang, Xijun
    Zhu, Xiangbing
    Luo, Haixia
    Hu, Zheng
    Zou, Xiaojun
    He, Qun
    MICROCHEMICAL JOURNAL, 2007, 87 (01) : 20 - 26
  • [5] Studies on the Solid Phase Extraction and Preconcentration of Zirconium, Hafnium, Molybdenum, and Tungsten With Chitin for Their Determination in Geological Samples by ICP-AES
    Padmasubashini, V.
    Murty, D. S. R.
    ATOMIC SPECTROSCOPY, 2009, 30 (01) : 32 - 40
  • [6] NOVEL FUNCTIONALIZED SOLID PHASE FOR PRECONCENTRATION AND DETERMINATION OF TRACE Cu(II), Fe(III), Zn(II) AND Pb(II) FROM WATER SAMPLES USING FAAS
    Dogan, Canan Ekinci
    FRESENIUS ENVIRONMENTAL BULLETIN, 2018, 27 (04): : 1989 - 1998
  • [7] Determination of Niobium and Tantalum in Geological Samples by ICP-AES After Preconcentration by Solid Phase Extraction on Activated Carbon or Chitin
    Padmasubashini, V.
    Murty, D. S. R.
    ATOMIC SPECTROSCOPY, 2011, 32 (01) : 17 - 26
  • [8] Determination of Cr, Ni, Zn, Cu, and Cd in the industrial waste water by ICP-AES
    Beijing Inst of Aeronautical, Materials, Beijing, China
    Cailiao Gongcheng, 10 (32-34):
  • [9] DETERMINATION OF Cr(III), Fe(III), Ni(II), Pb(II) AND Zn(II) IONS BY FAAS IN ENVIRONMENTAL SAMPLES AFTER SEPARATION AND PRECONCENTRATION BY SOLVENT EXTRACTION USING A TRIKETONE REAGENT
    Sacmaci, Serife
    Kartal, Senol
    Sacmaci, Mustafa
    FRESENIUS ENVIRONMENTAL BULLETIN, 2012, 21 (6A): : 1563 - 1570
  • [10] Synthesis and Application of Glutaric Dihydrazide Modified Multiwalled Carbon Nanotubes for Selective Solid-Phase Extraction and Preconcentration of Cu(II), Zn(II), Ni(II), and Fe(III)
    Tavallali, Hossein
    Zahmatkesh, Saeed
    Aalaei, Mehdi
    Abdardideh, Dawood
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (03) : 897 - 902