Experimental Study on the Noise Characteristics Regarding Axial Auxiliary Fans and the Noise Reduction Performance of Mufflers

被引:0
|
作者
Cheng Zhai
Zongqing Tang
Quanle Zou
Lei Qin
机构
[1] China University of Mining and Technology,Key Laboratory of Coal Methane and Fire Control, Ministry of Education
[2] State Key Laboratory of Coal Resources and Safety Mining,School of Safety Engineering
[3] China University of Mining and Technology,undefined
关键词
Axial auxiliary fan; Air inlet; Air outlet; Noise distribution; Spectrum analysis; Muffler;
D O I
暂无
中图分类号
学科分类号
摘要
High-intensity noise not only hurts body and mental health of workers, but also covers sound signs of accidence. To increase the sound absorption and noise reduction performance of axial auxiliary fan noise silencers, the noise strength and frequency distribution of the ambient medium casing of an FBYNo3.0/2.2 (II) axial auxiliary fan were investigated. The noise characteristics at the inlets and outlets were analyzed. Based on this study, a new auxiliary fan bell-type muffler was designed, and its noise elimination ability was tested. The results showed that on the surface of the auxiliary fan casing, the noise intensity exhibited a “V” font distribution in that the maximum noise intensity was located in the air outlet and the minimum noise intensity was located in the middle part of the fan. Mid- and low-frequency noise was presented primarily at the outlets. However, intermediate- and high-frequency noise was presented primarily at the inlets. The muffler performance test revealed that the installation of a muffler can dramatically reduce the intensity of the auxiliary fan’s noise. The mean decrease in noise intensity for various positions was 14 dB (A). The noise elimination rate of the muffler was over 15 %. This decreased level of noise was less than the Chinese national standard for maximum noise intensity, 85 dB (A). In addition, optimizing the noise frequency of the inlets and outlets by decreasing the intermediate- and high-frequency noise of the inlets and the intermediate- and low-frequency noise of the outlets can lead to the greatest noise reduction.
引用
收藏
页码:4817 / 4826
页数:9
相关论文
共 50 条
  • [1] Experimental Study on the Noise Characteristics Regarding Axial Auxiliary Fans and the Noise Reduction Performance of Mufflers
    Zhai, Cheng
    Tang, Zongqing
    Zou, Quanle
    Qin, Lei
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2016, 41 (12) : 4817 - 4826
  • [3] Experimental Study on Aerodynamic Noise Reduction of In-series Axial Cooling Fans for Electronic Devices
    Sun Z.
    Tian J.
    Du Z.
    Ouyang H.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2022, 58 (22): : 406 - 415
  • [4] Case study: Numerical study of the noise reduction characteristics of corrugated perforated pipe mufflers
    Hou, Zhenhua
    Xu, Tanghong
    Zhang, Zhijun
    Sun, Jiyu
    NOISE CONTROL ENGINEERING JOURNAL, 2022, 70 (01) : 16 - 36
  • [5] High frequency noise reduction in small axial flow fans
    Quinlan, DA
    Bent, PH
    Krane, MH
    PROCEEDINGS OF NOISE-CON 96 - THE 1996 NATIONAL CONFERENCE ON NOISE CONTROL ENGINEERING, VOLS 1 AND 2, 1996, : 15 - 20
  • [6] Noise characterization and reduction techniques of multiple axial fans unit
    2017, Canadian Acoustical Association (45):
  • [7] EXPERIMENTAL-STUDY ON NOISE-REDUCTION FROM PROPELLER FANS
    HARADA, I
    KIKUSHIMA, Y
    JOURNAL OF MECHANICAL ENGINEERING LABORATORY, 1979, 33 (06): : 294 - 306
  • [8] Analysis and test on the flow characteristics and noise of axial flow fans
    Son, Young-Woo
    Choi, Ji-Hun
    Lee, Jangho
    Park, Seong-Ryong
    Kim, Minsung
    Kim, Jae Won
    EKC2008: PROCEEDINGS OF THE EU-KOREA CONFERENCE ON SCIENCE AND TECHNOLOGY, 2008, 124 : 85 - +
  • [9] SOURCES OF NOISE IN AXIAL FLOW FANS
    SHARLAND, IJ
    JOURNAL OF SOUND AND VIBRATION, 1964, 1 (03) : 302 - &
  • [10] NOISE GENERATION IN AXIAL FLOW FANS
    VANNIEKERK, CG
    JOURNAL OF SOUND AND VIBRATION, 1966, 3 (01) : 46 - +