Luminescence imaging of biological subjects during X-ray irradiations lower energy than Cerenkov-light threshold

被引:0
|
作者
Seiichi Yamamoto
Shuji Koyama
Chiyo Yamauchi-Kawaura
Masataka Komori
机构
[1] Nagoya University Graduate School of Medicine,Radiological and Medical Laboratory Sciences
来源
Optical Review | 2017年 / 24卷
关键词
Luminescence; Imaging; Biological subjects; X-ray irradiations; Cerenkov-light threshold;
D O I
暂无
中图分类号
学科分类号
摘要
It is commonly thought that UV or visible-light luminescence imaging of biological subjects during X-ray irradiation at the energy below 120 keV is impossible because the secondary electrons produced in this energy range do not emit Cerenkov light. Contrary to this consensus, we found UV or visible-light luminescence imaging of the subjects were possible with X-ray irradiations of this energy range. We placed one of the biological subjects in a black box; visible-light luminescence images were measured with a high-sensitivity, cooled charge coupled device (CCD) camera during X-ray irradiation at energy below 120 keV. We also conducted the imaging of air without subjects during irradiation of the same X-ray. The biological subjects emitted visible-light luminescence, and the imaging was possible with the irradiation of the X-ray below 120 keV. The luminescence images were observed in only the X-ray irradiated areas. Also air luminescence images could be obtained and the intensity of the luminescence measured from the images was proportionally increased with the exposure dose. UV or visible-light luminescence imaging of biological subjects was possible during X-ray irradiations lower energy than the Cerenkov-light threshold. The phenomenon was different from general X-ray fluorescence because wavelength of the luminescence is UV or visible-light. The luminescence imaging method is promising for estimating the irradiated area with X-ray, which could be used for interventional radiology (IVR). Also air luminescence imaging would be applied to the exposure dose distribution measurements for X-ray of diagnostic X-ray systems.
引用
收藏
页码:428 / 435
页数:7
相关论文
共 50 条
  • [1] Luminescence imaging of biological subjects during X-ray irradiations lower energy than Cerenkov-light threshold
    Yamamoto, Seiichi
    Koyama, Shuji
    Yamauchi-Kawaura, Chiyo
    Komori, Masataka
    OPTICAL REVIEW, 2017, 24 (03) : 428 - 435
  • [2] Luminescence Imaging of Water during Irradiation of Beta Particles with Energy Lower Than Cerenkov-Light Threshold
    Yamamoto S.
    Yamamoto, Seiichi (s-yama@met.nagoya-u.ac.jp), 1600, Institute of Electrical and Electronics Engineers Inc. (01): : 329 - 333
  • [3] Luminescence imaging of water during irradiation of X-ray photons lower energy than Cerenkov- light threshold
    Yamamoto, Seiichi
    Koyama, Shuji
    Komori, Masataka
    Toshito, Toshiyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 832 : 264 - 270
  • [4] Source of luminescence of water lower energy than the Cerenkov-light threshold during irradiation of carbon-ion
    Yamamoto, Seiichi
    Akagi, Takashi
    Yamashita, Tomohiro
    Toivonen, Juha
    Yamaguchi, Mitsutaka
    Komori, Masataka
    Kawachi, Naoki
    JOURNAL OF PHYSICS COMMUNICATIONS, 2018, 2 (06):
  • [5] Optical imaging of produced light in water during irradiation of gamma photons lower energy than the Cerenkov-light threshold
    Yamamoto, Seiichi
    Kato, Katsuhiko
    Abe, Shinji
    APPLIED RADIATION AND ISOTOPES, 2020, 157
  • [6] Stability and linearity of luminescence imaging of water during irradiation of proton-beams and X-ray photons lower energy than the Cerenkov light threshold
    Yamamoto, Seiichi
    Koyama, Shuji
    Yabe, Takuya
    Komori, Masataka
    Tada, Junki
    Ito, Shiori
    Toshito, Toshiyuki
    Hirata, Yuho
    Watanabe, Kenichi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 883 : 48 - 56
  • [7] Measurements of temporal response of luminescence of water at lower energy than Cerenkov-light threshold during carbon-ion irradiation
    Yamamoto, Seiichi
    Akagi, Takashi
    Hirano, Yoshiyuki
    Komori, Masataka
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04):
  • [8] Estimation of the fractions of luminescence of water at higher energy than Cerenkov-light threshold for various types of radiation
    Hirano, Yoshiyuki
    Yamamoto, Seiichi
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (06)
  • [9] Measurements of intensity of produced light in water during irradiations of electron beams with energies above and below the Cerenkov-light threshold
    Yamamoto, S.
    Nagao, Y.
    Kurita, K.
    Yamaguchi, M.
    Kawachi, N.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (01):
  • [10] Angular dependencies of Cerenkov-light in water for carbon-ion, high energy x-ray and electron
    Hirano, Yoshiyuki
    Yamamoto, Seiichi
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (02):