Evaluation of plastic hinge length in RC shear wall connected with floor slabs

被引:0
|
作者
S. Kaushik
K. Dasgupta
机构
[1] Girijananda Chowdhury University,Department of Civil Engineering
[2] Indian Institute of Technology Guwahati,Department of Civil Engineering
来源
关键词
Shear wall-slab junction; Finite element analysis; Nonlinear static analysis; Plastic hinge length;
D O I
10.1007/s44290-024-00010-0
中图分类号
学科分类号
摘要
Traditionally, seismic design focuses on inelastic behavior at the base of isolated shear walls. Yet, in multistoried RC wall-frame buildings with interconnected shear walls and floor slabs, significant inelasticity occurs at wall-slab junctions. This interaction greatly enhances the structure's seismic capacity. Previous studies overlooked this interaction, concentrating instead on isolated walls. The extent of inelastic action in a wall connected with floor slabs has not been studied extensively in the past. In the present study, the extent of the zone of inelastic behavior is studied at the wall-slab junction region by carrying out displacement based nonlinear static analysis of the wall-slab assemblages under monotonic as well as cyclic loads. A parametric study is carried out by varying the wall panel aspect ratio and axial load on walls. It is observed that this interaction using nonlinear static analysis, revealing increased curvature demand and localized damages at the junctions. It is observed that the extent of tensile damage at the junction region remains consistent across different axial load levels at the maximum drift level. Analytical expressions for plastic hinge length are proposed, crucial for refining seismic design strategies. The plastic hinge equation derived from pushover analysis yields values approximately 1.34 times higher than those obtained from cyclic loading.
引用
收藏
相关论文
共 50 条
  • [1] Research on Plastic Hinge Length of RC Shear Walls with Flange
    Wang B.
    Shi Q.
    Wu M.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2022, 55 (08): : 848 - 861
  • [2] Study on the equivalent plastic hinge length of superimposed RC shear walls with embedded bracings
    Guo, Shengqi
    Wang, Mengfu
    STRUCTURES, 2023, 51 : 455 - 471
  • [3] The plastic hinge length prediction of RC members by using ANN
    Barış BAYRAK
    Oğuzhan AKARSU
    Gökhan KAPLAN
    Abdulkadir Cüneyt AYDIN
    Sādhanā, 48
  • [4] Plastic hinge length of RC shear walls: Practical approximation via machine learning and probabilistic assessment
    Jafari, Abouzar
    Mirrashid, Masoomeh
    Hoult, Ryan D.
    Zhou, Ying
    ENGINEERING FAILURE ANALYSIS, 2025, 169
  • [5] The plastic hinge length prediction of RC members by using ANN
    Bayrak, Baris
    Akarsu, Oguzhan
    Kaplan, Gokhan
    Aydin, Abdulkadir Cuneyt
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2023, 48 (03):
  • [6] Effect of load cycling on plastic hinge length in RC columns
    Yuan, Fang
    Wu, Yu-Fei
    ENGINEERING STRUCTURES, 2017, 147 : 90 - 102
  • [7] Study on Plastic Hinge Length and Limit Curvature of RC Column
    Xie Yongping
    Jia Lei
    Sun Gang
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 378 - 381
  • [8] Estimation of factors influencing the punching shear strength of RC floor slabs
    Šalna, Remigijus
    Marčiukaitis, Gediminas
    Vainiunas, Povilas
    Journal of Civil Engineering and Management, 2005, 10 (SUPPL. 2) : 137 - 142
  • [9] Seismic performance analysis of RC shear wall structure with fiber-reinforced concrete in plastic hinge region
    Han, Jun
    Zhai, Yonglin
    Zhang, Hui
    Li, Yingmin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 : 47 - 54
  • [10] Plastic Hinge Length of FRP-Confined Square RC Columns
    Jiang, Cheng
    Wu, Yu-Fei
    Wu, Gang
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (04)