Effect of Weiss ring on peripapillary retinal nerve fiber layer thickness measurements using SD-OCT

被引:0
|
作者
Min-Su Kim
Ki-Yup Nam
Young Hoon Hwang
Min-Woo Lee
Woo-Hyuk Lee
Hyung-Bin Lim
Jung-Yeul Kim
机构
[1] 1.0 Eye Clinic,Department of Ophthalmology
[2] Chungnam National University College of Medicine,Department of Ophthalmology
[3] Chungnam National University College of Medicine,Department of Ophthalmology
[4] Konyang University College of Medicine, Department of Ophthalmology
[5] Gyeongsang National University College of Medicine,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Spectral-domain optical coherence tomography (SD-OCT) must accurately identify and measure the peripapillary retinal nerve fiber layer (pRNFL) thickness to improve the repeatability and reproducibility, and reduce measurement errors. Because Weiss ring can be located in front of the optic disc, we hypothesized that it may affect pRNFL thickness measurements obtained using SD-OCT. We retrospectively reviewed the medical records of patients with (group W) and without (group N) Weiss ring, observed on OCT fundus image and an RNFL map devised using SD-OCT. Optic disc cube scans (200 × 200) were obtained to measure pRNFL thicknesses (superior, temporal, inferior, nasal, and average) at two consecutive visits. Pearson's correlation coefficient (r), intraclass correlation coefficient (ICC), and coefficient of variation (CV) were calculated. The r and ICC values for the pRNFL thickness measurements at the two visits were lower for group W compared to group N, but statistical significance was reached only for inferior pRNFL thickness. In addition, CV values were greater for group W compared to group N, but the differences were significant only for inferior and average pRNFL thickness measurements (p < 0.001 and p = 0.004, respectively). Weiss ring located near the optic disc can affect pRNFL thickness measurements and repeatability thereof, especially the inferior quadrant and average values. Therefore, it is important to identify the presence of Weiss ring when analyzing pRNFL thickness values.
引用
收藏
相关论文
共 50 条
  • [1] Effect of Weiss ring on peripapillary retinal nerve fiber layer thickness measurements using SD-OCT
    Kim, Min-Su
    Nam, Ki-Yup
    Hwang, Young Hoon
    Lee, Min-Woo
    Lee, Woo-Hyuk
    Lim, Hyung-Bin
    Kim, Jung-Yeul
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [2] Peripapillary Retinal Nerve Fiber Layer (RNFL) Thickness Measurements by Topcon SD-OCT in Myopic Patients
    Akhtar, Nadia
    Kausar, Ayisha
    Afzal, Farooq
    Ali, Syed Khalid
    Hamid, Nida
    [J]. JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2018, 28 (01): : 26 - 30
  • [3] The Weiss Ring, a Major Confounding Factor For Measurements of Peripapillary Retinal Nerve Fiber Layer Thickness
    Lee, Min-woo
    Kim, Min-su
    Yu, Hwa-young
    Park, Kee-sup
    Lee, Young-hoon
    Kim, Jung-yeul
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 238 : 134 - 140
  • [4] Detection of the Onset of Multiple Sclerosis from SD-OCT Thickness Measurements of the Retinal Nerve Fiber Layer
    Ledolter, Johannes
    Kardon, Randy
    [J]. QUALITY ENGINEERING, 2013, 25 (01) : 3 - 10
  • [5] Comparing retinal nerve fiber layer thickness between SD-OCT and AO-OCT
    King, Brett
    Swanson, William H.
    Kurokawa, Kazuhiro
    Miller, Donald Thomas
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [6] Effect of Age on Healthy Retinal Nerve Fiber Layer Thickness Measurements Using Spectral-Domain Optical Coherence Tomography (SD-OCT)
    Layer, N.
    Soliman, A.
    Wu, H.
    De Boer, J. F.
    Chen, T. C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [7] Effect of refractive errors/axial length on peripapillary retinal nerve fibre layer thickness (RNFL) measured by Topcon SD-OCT
    Kausar, Ayisha
    Akhtar, Nadia
    Afzal, Farooq
    Ali, Khalid
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2018, 68 (07) : 1054 - 1059
  • [8] The Optimal Diameter for Circumpapillary Retinal Nerve Fiber Layer Thickness Measurement by SD-OCT in Glaucoma
    Heindl, Ludwig M.
    Adler, Werner
    El-Malahi, Ouahiba
    Schaub, Friederike
    Hermann, Manuel M.
    Dietlein, Thomas S.
    Cursiefen, Claus
    Enders, Philip
    [J]. JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1086 - 1093
  • [9] Effect of Axial Length on the Difference Between SS-OCT and SD-OCT Retinal Nerve Fiber Layer Thickness Measurements in Highly Myopic Eyes
    Loh, Isabella
    Chong, Rachel S.
    Tan, Bingyao
    Yu, Daryle Jason
    Wong, Qiu Ying
    Dan, Yee Shan
    Wong, Chee Wai
    Hoang, Quan V.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [10] Peripapillary retinal nerve fibre layer thickness measurement with SD-OCT in normal and glaucomatous eyes:distribution and correlation with age
    George Kampougeris
    Dimitrios Spyropoulos
    Adrianna Mitropoulou
    Aggeliki Zografou