Tidal volume and airway pressure under percutaneous transtracheal ventilation without a jet ventilator: comparison of high-flow oxygen ventilation and manual ventilation in complete and incomplete upper airway obstruction models

被引:0
|
作者
Nobuko Sasano
Akemi Tanaka
Ai Muramatsu
Yoshihito Fujita
Shoji Ito
Hiroshi Sasano
Kazuya Sobue
机构
[1] Nagoya City West Medical Center,Department of Anesthesia
[2] Nagoya City University Graduate School of Medical Sciences,Department of Anesthesiology and Medical Crisis Management
[3] Nagoya City East Medical Center,Department of Anesthesia
来源
Journal of Anesthesia | 2014年 / 28卷
关键词
Difficult airway; Tidal volume; Airway pressure;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:341 / 346
页数:5
相关论文
共 13 条
  • [1] Tidal volume and airway pressure under percutaneous transtracheal ventilation without a jet ventilator: comparison of high-flow oxygen ventilation and manual ventilation in complete and incomplete upper airway obstruction models
    Sasano, Nobuko
    Tanaka, Akemi
    Muramatsu, Ai
    Fujita, Yoshihito
    Ito, Shoji
    Sasano, Hiroshi
    Sobue, Kazuya
    JOURNAL OF ANESTHESIA, 2014, 28 (03) : 341 - 346
  • [2] Percutaneous Transtracheal Jet Ventilation with Various Upper Airway Obstruction
    Doi, Tomoki
    Miyashita, Tetsuya
    Furuya, Ryousuke
    Sato, Hitoshi
    Takaki, Shunsuke
    Goto, Takahisa
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [3] TIDAL VOLUME AND AIRWAY PRESSURE ON HIGH-FREQUENCY JET VENTILATION
    CARLON, GC
    RAY, C
    GRIFFIN, J
    MIDOWNIK, S
    GROEGER, JS
    CRITICAL CARE MEDICINE, 1983, 11 (02) : 83 - 86
  • [4] FURTHER STUDIES ON TRANSTRACHEAL VENTILATION - INFLUENCE OF UPPER AIRWAY OBSTRUCTION ON PATTERNS OF PRESSURE AND VOLUME CHANGES
    CHAKRAVARTY, K
    NARAYANAN, PS
    SPOEREL, WE
    BRITISH JOURNAL OF ANAESTHESIA, 1973, 45 (07) : 733 - 737
  • [5] Percutaneous transtracheal jet ventilation as a guide to tracheal intubation in severe upper airway obstruction from supraglottic oedema
    Chandradeva, K
    Palin, C
    Ghosh, SM
    Pinches, SC
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (05) : 683 - 686
  • [6] Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure
    Cordioli R.L.
    Park M.
    Costa E.L.V.
    Gomes S.
    Brochard L.
    Amato M.B.P.
    Azevedo L.C.P.
    Intensive Care Medicine Experimental, 2 (1)
  • [7] Comparison of catheter high-frequency jet ventilation and conventional ventilation during interventional bronchoscopy in patients with upper airway obstruction
    Paulikova, M.
    Matula, P.
    ANESTEZIOLOGIE A INTENZIVNI MEDICINA, 2018, 29 (04): : 187 - 192
  • [8] Use of the Ventrain® in a patient with complete upper airway obstruction preventing expiration during high-frequency jet ventilation
    Fearnley, A.
    Badiger, S.
    Oakley, R.
    Ahmad, I.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E903 - E903
  • [9] A bench study of ventilation via two self-assembled jet devices and the Oxygen Flow Modulator in simulated upper airway obstruction
    Hamaekers, A. E. W.
    Borg, P. A. J.
    Enk, D.
    ANAESTHESIA, 2009, 64 (12) : 1353 - 1358
  • [10] A COMPARISON OF THE EFFECTS OF HIGH-FREQUENCY LOW TIDAL VOLUME AND LOW-FREQUENCY HIGH TIDAL VOLUME MECHANICAL VENTILATION - THE SIGNIFICANCE OF MEAN AIRWAY PRESSURE
    BOROS, SJ
    CAMPBELL, KR
    JOURNAL OF PEDIATRICS, 1980, 96 (06): : 1119 - 1119