Diagnostics of VVER-1000 Coolant Temperature Pulsations

被引:0
|
作者
S. V. Priymak
机构
[1] Luch Research Institute and Scientific Industrial Association (NII NPO Luch),
[2] Podolsk,undefined
来源
Atomic Energy | 2019年 / 125卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The temperature pulsations arising in coolant flow at the entry into FA are examined from the standpoint of the possibility of their diagnostics by thermocouples of the protective-tube block are examined. It is shown that the temperature pulsations remain in the FA and can be recorded at the exit from FA by means of the in-reactor monitoring system. The aim of this work is to call the attention of specialists working in the field of temperature diagnostics of nuclear power facilities to the application of the elements of the theory of generalized functions, specifically, the fundamental solutions of heat-conduction operators and the methods of integral transformations of generalized functions, which are powerful means for solving applied problems of the temperature diagnostics of NPF in order to increase their operational safety.
引用
收藏
页码:297 / 300
页数:3
相关论文
共 50 条
  • [1] DIAGNOSTICS OF VVER-1000 COOLANT TEMPERATURE PULSATIONS
    Priymak, S., V
    [J]. ATOMIC ENERGY, 2019, 125 (05) : 297 - 300
  • [2] TEMPERATURE REGULATION AND MANEUVERABILITY OF VVER-1000
    Averyanova, S. P.
    Dubov, A. A.
    Kosourov, K. B.
    Filimonov, P. E.
    [J]. ATOMIC ENERGY, 2011, 109 (04) : 246 - 251
  • [3] Temperature regulation and maneuverability of VVER-1000
    S. P. Averyanova
    A. A. Dubov
    K. B. Kosourov
    P. E. Filimonov
    [J]. Atomic Energy, 2011, 109 : 246 - 251
  • [4] Neutronic analysis of nanofluids as a coolant in the Bushehr VVER-1000 reactor
    Zarifi, Ehsan
    Jahanfarnia, Gholamreza
    Veisy, Farzad
    [J]. NUKLEONIKA, 2012, 57 (03) : 375 - 381
  • [5] Incorporation of the procedure for monitoring coolant boiling in a VVER-1000 core into the in-reactor noise diagnostics system
    Semchenkov, Yu. M.
    Mil'to, V. A.
    Shumskii, B. E.
    [J]. ATOMIC ENERGY, 2008, 105 (02) : 99 - 103
  • [6] Incorporation of the procedure for monitoring coolant boiling in a VVER-1000 core into the in-reactor noise diagnostics system
    Yu. M. Semchenkov
    V. A. Mil’to
    B. E. Shumskii
    [J]. Atomic Energy, 2008, 105 : 99 - 103
  • [7] Application of global optimization to VVER-1000 reactor diagnostics
    Kinelev, VG
    Shkapov, PM
    Sulimov, VD
    [J]. PROGRESS IN NUCLEAR ENERGY, 2003, 43 (1-4) : 51 - 56
  • [8] THE ANALYSIS OF INFLUENCE OF FUEL PELLET AND COOLANT TEMPERATURE DISTRIBUTIONS ON THE VVER-1000 ACTIVE CORE CHARACTERISTICS
    Mishin, A. A.
    Galchenko, V. V.
    [J]. PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 6, 2014,
  • [9] Model Studies of Coolant Flow Hydrodynamics at VVER-1000 Core Entry
    Krapivtsev, V. G.
    Solonin, V. I.
    [J]. ATOMIC ENERGY, 2021, 130 (01) : 13 - 19
  • [10] Investigation of thermal performance of aluminum nanoparticle coolant in vver-1000 reactor
    Uzun, Sinem
    Genc, Yasin
    Acir, Adem
    [J]. JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2021, 24 (03): : 1009 - 1015