Value of blood pool contrast agents in magnetic resonance angiography of the pelvis and lower extremities

被引:0
|
作者
M. Saeed
M. F. Wendland
M. Engelbrecht
H. Sakuma
C. B. Higgins
机构
[1] Department of Radiology,
[2] University of California,undefined
[3] San Francisco,undefined
[4] CA 94143,undefined
[5] USA,undefined
来源
European Radiology | 1998年 / 8卷
关键词
Key words: Magnetic resonance angiography; Blood pool MR contrast agents; Ultrasmall superparamagnetic iron oxide; Peripheral vessels;
D O I
暂无
中图分类号
学科分类号
摘要
Our objective was: (1) to determine the appropriate dose of new ultrasmall superparamagnetic iron oxide particles for magnetic resonance angiography (MRA). This agent comprised of a single iron oxide crystal stabilized with a carbohydrate-polyethylene glycol coat (PEG-Ferron/NC 100150 injection); (2) to determine the proper flip angle for PEG-Ferron-enhanced 3 D time-of-flight (TOF) MRA sequence; and (3) to compare the enhancement of peripheral vessels following PEG-Ferron and GdDTPA-BMA. MRA parameters were: TR/TE = 50/2.1 ms, NEX = 1, FOV = 30 × 30 × 1.8 cm, and matrix = 256 × 128 × 64. In anesthetized beagle dogs (n = 10), the effects of PEG-Ferron and GdDTPA-BMA on regional signal were monitored for 45 min and compared. The lowest dose of PEG-Ferron (0.05 mmol/kg) produced the best enhancement of primary, secondary and tertiary vessels. The flip angle 60 ° provided better enhancement than 20 ° on contrast enhanced images. Unlike GdDTPA-BMA, PEG-Ferron allowed prolonged delineation (> 45 min) of the pelvis and lower extremities circulation. PEG-Ferron provided greater Contrast-to-noise ratio CNR (80.2 ± 6.2, P < 0.05) than GdDTPA-BMA (63.5 ± 2.5). It may be possible for blood pool contrast-enhanced 3 D TOF MRA to provide valuable information for visualization of vascular tree including guiding interventions.
引用
收藏
页码:1047 / 1053
页数:6
相关论文
共 50 条
  • [1] Value of blood pool contrast agents in magnetic resonance angiography of the pelvis and lower extremities
    Saeed, M
    Wendland, MF
    Engelbrecht, M
    Sakuma, H
    Higgins, CB
    [J]. EUROPEAN RADIOLOGY, 1998, 8 (06) : 1047 - 1053
  • [2] Value of blood pool contrast agents in magnetic resonance venography of the lower extremities and pelvis
    Aschauer, MA
    Stollberger, R
    Hausegger, KA
    Doder, S
    Raith, J
    Ebner, F
    [J]. RADIOLOGY, 1999, 213P : 221 - 221
  • [3] Value of blood pool contrast agent in magnetic resonance venography (MRV) of the lower extremities and pelvis
    Aschauer, M
    Stollberger, R
    Hausegger, KA
    Raith, J
    Doder, S
    Ebner, F
    [J]. CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 414 - 418
  • [4] Magnetic resonance angiography with blood-pool contrast agents: future applications
    Fink, Christian
    Goyen, Mathias
    Lotz, Joachim
    [J]. EUROPEAN RADIOLOGY, 2007, 17 : B38 - B44
  • [5] MR angiography with blood pool contrast agents MR angiography with blood pool contrast agents
    Bremerich, Jens
    Bilecen, Deniz
    Reimer, Peter
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (12) : 3017 - 3024
  • [6] Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis:: Preliminary results in 12 patients
    Aschauer, M
    Deutschmann, HA
    Stollberger, R
    Hausegger, KA
    Obernosterer, A
    Schöllnast, H
    Ebner, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 993 - 1002
  • [7] The future of contrast-enhanced magnetic resonance angiography -: Are blood pool agents needed?
    Mühler, A
    [J]. INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 709 - 714
  • [8] MAGNETIC-RESONANCE ANGIOGRAPHY OF THE PELVIS AND LOWER-EXTREMITIES - WORKS IN PROGRESS
    SCHIEBLER, ML
    LISTERUD, J
    HOLLAND, G
    OWEN, R
    BAUM, R
    KRESSEL, HY
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 : S90 - S96
  • [9] Blood pool contrast agents for venous magnetic resonance imaging
    Oliveira, Irai S.
    Hedgire, Sandeep S.
    Li, Weier
    Ganguli, Suvranu
    Prabhakar, Anand M.
    [J]. CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2016, 6 (06) : 508 - 518
  • [10] MR angiography with blood pool contrast agents
    Jens Bremerich
    Deniz Bilecen
    Peter Reimer
    [J]. European Radiology, 2007, 17