Measurement of the cavity-loaded quality factor in superconducting radio-frequency systems with mismatched source impedance

被引:0
|
作者
Jin-Ying Ma
Cheng-Ye Xu
An-Dong Wu
Guo-Dong Jiang
Yue Tao
Zong-Heng Xue
Long-Bo Shi
Tian-Cai Jiang
Zheng-Long Zhu
Zi-Qin Yang
Zheng Gao
Lie-Peng Sun
Gui-Rong Huang
Feng Qiu
Yuan He
机构
[1] Chinese Academy of Sciences,Institute of Modern Physics
[2] University of Chinese Academy of Sciences,School of Nuclear Science and Technology
来源
关键词
Loaded quality factor; Field decay method; Superconducting cavity; Mismatch; Calibration; Cavity differential equation; Measurement; Accelerator-driven system;
D O I
暂无
中图分类号
学科分类号
摘要
The accurate measurement of parameters such as the cavity-loaded quality factor (QL\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$Q_\textrm{L}$$\end{document}) and half bandwidth (f0.5\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$f_{0.5}$$\end{document}) is essential for monitoring the performance of superconducting radio-frequency cavities. However, the conventional “field decay method" employed to calibrate these values requires the cavity to satisfy a “zero-input" condition. This can be challenging when the source impedance is mismatched and produce nonzero forward signals (Vf\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$V_\textrm{f}$$\end{document}) that significantly affect the measurement accuracy. To address this limitation, we developed a modified version of the “field decay method" based on the cavity differential equation. The proposed approach enables the precise calibration of f0.5\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$f_{0.5}$$\end{document} even under mismatch conditions. We tested the proposed approach on the SRF cavities of the Chinese Accelerator-Driven System Front-End Demo Superconducting Linac and compared the results with those obtained from a network analyzer. The two sets of results were consistent, indicating the usefulness of the proposed approach.
引用
收藏
相关论文
共 50 条
  • [1] Measurement of the cavity-loaded quality factor in superconducting radio-frequency systems with mismatched source impedance
    Ma, Jin-Ying
    Xu, Cheng-Ye
    Wu, An-Dong
    Jiang, Guo-Dong
    Tao, Yue
    Xue, Zong-Heng
    Shi, Long-Bo
    Jiang, Tian-Cai
    Zhu, Zheng-Long
    Yang, Zi-Qin
    Gao, Zheng
    Sun, Lie-Peng
    Huang, Gui-Rong
    Qiu, Feng
    He, Yuan
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2023, 34 (08)
  • [2] Measurement of the cavity-loaded quality factor in superconducting radio-frequency systems with mismatched source impedance
    Jin-Ying Ma
    Cheng-Ye Xu
    An-Dong Wu
    Guo-Dong Jiang
    Yue Tao
    Zong-Heng Xue
    Long-Bo Shi
    Tian-Cai Jiang
    Zheng-Long Zhu
    Zi-Qin Yang
    Zheng Gao
    Lie-Peng Sun
    Gui-Rong Huang
    Feng Qiu
    Yuan He
    [J]. Nuclear Science and Techniques, 2023, 34 (08) : 109 - 120
  • [3] Quality Factor Enhancement of 650 MHz Superconducting Radio-Frequency Cavity for CEPC
    Sha, Peng
    Pan, Weimin
    Zhai, Jiyuan
    Mi, Zhenghui
    Jin, Song
    Liu, Baiqi
    Dong, Chao
    He, Feisi
    Ye, Lingxi
    He, Xiangcong
    Zheng, Shiao
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (02):
  • [4] Ultrahigh accelerating gradient and quality factor of CEPC 650 MHz superconducting radio-frequency cavity
    Sha, Peng
    Pan, Wei-Min
    Jin, Song
    Zhai, Ji-Yuan
    Mi, Zheng-Hui
    Liu, Bai-Qi
    Dong, Chao
    He, Fei-Si
    Ge, Rui
    Sun, Liang-Rui
    Zheng, Shi-Ao
    Ye, Ling-Xi
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (10)
  • [5] Ultrahigh accelerating gradient and quality factor of CEPC 650 MHz superconducting radio-frequency cavity
    Peng Sha
    Wei-Min Pan
    Song Jin
    Ji-Yuan Zhai
    Zheng-Hui Mi
    Bai-Qi Liu
    Chao Dong
    Fei-Si He
    Rui Ge
    Liang-Rui Sun
    Shi-Ao Zheng
    Ling-Xi Ye
    [J]. Nuclear Science and Techniques, 2022, 33 (10) : 35 - 42
  • [6] Ultrahigh accelerating gradient and quality factor of CEPC 650 MHz superconducting radio-frequency cavity
    Peng Sha
    Wei-Min Pan
    Song Jin
    Ji-Yuan Zhai
    Zheng-Hui Mi
    Bai-Qi Liu
    Chao Dong
    Fei-Si He
    Rui Ge
    Liang-Rui Sun
    Shi-Ao Zheng
    Ling-Xi Ye
    [J]. Nuclear Science and Techniques, 2022, 33
  • [7] Structural Reinforcement on a Superconducting Radio-Frequency Cavity
    Tsai, Ming-Hsun
    Lin, Ming-Chyuan
    Wang, Chaoen
    Han, Lee-Long
    Tsung, Tsing-Tshih
    Furuya, Takaaki
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [8] QUENCH DETECTION ON A SUPERCONDUCTING RADIO-FREQUENCY CAVITY
    Lai, Ru-Yu
    Spirn, Daniel
    [J]. SIAM JOURNAL ON APPLIED MATHEMATICS, 2019, 79 (01) : 341 - 355
  • [9] Superconducting radio-frequency virtual cavity for control algorithms debugging
    Echevarria, Pablo
    Aldekoa, Eukeni
    Jugo, Josu
    Neumann, Axel
    Ushakov, Andriy
    Knobloch, Jens
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (08):
  • [10] Effect of high temperature heat treatments on the quality factor of a large-grain superconducting radio-frequency niobium cavity
    Dhakal, P.
    Ciovati, G.
    Myneni, G. R.
    Gray, K. E.
    Groll, N.
    Maheshwari, P.
    McRae, D. M.
    Pike, R.
    Proslier, T.
    Stevie, F.
    Walsh, R. P.
    Yang, Q.
    Zasadzinzki, J.
    [J]. PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2013, 16 (04):