Contact-free measurement of heart rate, respiration rate, and body movements during sleep

被引:0
|
作者
Mark Brink
Christopher H. Müller
Christoph Schierz
机构
[1] ETH Zürich,Center for Organizational and Occupational Sciences (ZOA)
[2] Ergonomie & Technologie GmbH,undefined
来源
Behavior Research Methods | 2006年 / 38卷
关键词
Respiration; Body Movement; Respiration Pattern; Heart Activity; Heart Rate Measurement;
D O I
暂无
中图分类号
学科分类号
摘要
We describe a noncontact method for the ambulant measurement of basic sleep physiology parameters in humans, particularly for field studies involving sleep research and sleep disturbances. This method traces the body movements, respiration, and heart action of a person at rest or asleep on a bed, using four high-resolution force sensors installed under the bedposts. The recoil movement of the body at each heartbeat, known as the cardioballistic effect, as well as the lifting and lowering of the thorax, while breathing, causes very small shifts of the center of gravity of the bed and the subject. These shifts are reflected in the altering force distributions across the four sensors. Cardiac and respiratory parameters and the subject’s movement activity can be calculated from the sensor signals. Neither electrodes nor other kinds of transducers are in direct contact with the subject, which is the main advantage of this technique over conventional methods. Laboratory experiments were carried out to estimate validity and practicability. The method has been found to be adequate, especially for automated and unattended sleep-data collection over long periods of time.
引用
下载
收藏
页码:511 / 521
页数:10
相关论文
共 50 条
  • [1] Contact-free measurement of heart rate, respiration rate, and body movements during sleep
    Brink, Mark
    Mueller, Christopher H.
    Schierz, Christoph
    BEHAVIOR RESEARCH METHODS, 2006, 38 (03) : 511 - 521
  • [2] A Microwave Sensor for Contact-Free Measurement of Human Heart Rate
    Lu, Guohua
    Yang, Fang
    Jing, Xijing
    Yu, Xiao
    Wang, Hua
    Wang, Jianqi
    ADVANCED MATERIALS IN MICROWAVES AND OPTICS, 2012, 500 : 325 - 329
  • [3] Contact-free Heart Rate Measurement Using Multiple Video Data
    Hung, Pang-Chan
    Lee, Kual-Zheng
    Tsai, Luo-Wei
    2013 INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL MODELS FOR LIFE SCIENCES, 2013, 1559 : 57 - 66
  • [4] A Novel Method for Contact-free Heart Rate Measurement Using Simulink
    Pawankiattikun, Vasitphon
    Lueangwattana, Chanya
    Kondo, Toshiaki
    Phatrapornnant, Teera
    Kaneko, Hirohiko
    2015 6TH INTERNATIONAL CONFERENCE OF INFORMATION AND COMMUNICATION TECHNOLOGY FOR EMBEDDED SYSTEMS (IC-ICTES), 2015,
  • [5] Contact-free Measurement of Heart Rate Variability via a Microwave Sensor
    Lu, Guohua
    Yang, Fang
    Tian, Yue
    Jing, Xijing
    Wang, Jianqi
    SENSORS, 2009, 9 (12) : 9572 - 9581
  • [6] A Method for Contact-free Heart Rate Measurement on a Video Sequence Using Simulink
    Pawankiattikun, Vasitphon
    Kondo, Toshiaki
    2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2014,
  • [7] A method for contact-free heart rate measurement on a video sequence using Simulink
    20150800547531
    (1) School of Information, Computer, and Communication Technology, Sirindhorn International Institute of Technology, Thammasat University, Pathumthani, Thailand, 1600, IEEE Fukuoka Section (Institute of Electrical and Electronics Engineers Inc., United States):
  • [8] Smartphone sonar-based contact-free respiration rate monitoring
    Wang X.
    Huang R.
    Yang C.
    Mao S.
    ACM Transactions on Computing for Healthcare, 2021, 2 (02):
  • [9] Validation of a novel contact-free heart and respiratory rate monitor
    Havakuk, Ofer
    Sadeh, Ben
    Merdler, Ilan
    Zalevsky, Zeev
    Garcia-Monreal, Javier
    Polani, Sagi
    Arbel, Yaron
    Journal of Medical Engineering and Technology, 2021, 45 (05): : 344 - 350
  • [10] Contact-free measurement of respiratory rate using infrared and vibration sensors
    Erden, Fatih
    Alkar, Ali Ziya
    Cetin, Ahmet Enis
    INFRARED PHYSICS & TECHNOLOGY, 2015, 73 : 88 - 94