A mobile lab-on-a-chip device for on-site soil nutrient analysis

被引:0
|
作者
M. Smolka
D. Puchberger-Enengl
M. Bipoun
A. Klasa
M. Kiczkajlo
W. Śmiechowski
P. Sowiński
C. Krutzler
F. Keplinger
M. J. Vellekoop
机构
[1] Vienna University of Technology,Institute of Sensor and Actuator Systems (ISAS)
[2] University Bremen,Institute for Microsensors,
[3] Warmia and Mazury University in Olsztyn,Actuators and
[4] Warmia and Mazury University in Olsztyn,Systems (IMSAS), MCB
[5] Austrian Center for Medical Innovation and Technology GmbH (ACMIT),Department of Agricultural Chemistry and Environmental Protection
来源
Precision Agriculture | 2017年 / 18卷
关键词
On-site soil nutrient sensor; NPK; Microfluidics; Lab-on-a-chip; Capillary electrophoresis; Capacitively coupled conductivity detection C; D; Capacitively coupled conductivity measurement C; M;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, a mobile sensor for on-site analysis of soil sample extracts is presented. As a versatile tool for scanning ion concentrations in liquid samples, it especially allows the analysis of NO3, NH4, K and PO4. The sensor mainly consists of a microfluidic chip in which the sample ions are separated in an electric field (capillary electrophoresis) and the individual ion concentrations are detected by a conductivity measurement. For the adaption of the device to field conditions, two major concerns were addressed. Firstly, nano-porous material was used as a barrier between the sample container and the analysis channel of the microfluidic chip. This prevents pressure driven leakage of the sample into the chip due to non-horizontal orientation of the device. Secondly, a new method for the injection of the sample into the chip was used. It reduces the number of fluidic connections between chip and operation device to three instead of the commonly used four connections. The sensor performance was tested on multi-ion solutions with calibration series for NO3, NH4, K and PO4. For the first on-site test, a quick soil nutrient extraction procedure with water was used. The sensor data was compared to standard laboratory results. The potential of the sensor for soil nutrient analysis is discussed together with required improvements of the sensor performance and of the nutrient extraction procedure.
引用
收藏
页码:152 / 168
页数:16
相关论文
共 50 条
  • [1] A mobile lab-on-a-chip device for on-site soil nutrient analysis
    Smolka, M.
    Puchberger-Enengl, D.
    Bipoun, M.
    Klasa, A.
    Kiczkajlo, M.
    Smiechowski, W.
    Sowinski, P.
    Krutzler, C.
    Keplinger, F.
    Vellekoop, M. J.
    [J]. PRECISION AGRICULTURE, 2017, 18 (02) : 152 - 168
  • [2] On-site genetic analysis for species identification using lab-on-a-chip
    Wimbles, Ryan
    Melling, Louise M.
    Cain, Bradley
    Davies, Naomi
    Doherty, Jason
    Johnson, Bridget
    Shaw, Kirsty J.
    [J]. ECOLOGY AND EVOLUTION, 2021, 11 (04): : 1535 - 1543
  • [3] Lab On Chip: Portable Optical Device for On-Site Multi-parametric Analysis
    Rampazzi, S.
    Danese, G.
    Fornasari, L.
    Leporati, F.
    Marabelli, F.
    Nazzicari, N.
    Valsesia, A.
    [J]. 16TH EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN (DSD 2013), 2013, : 807 - 810
  • [4] Lab-on-a-chip Sensor for In Situ Nutrient Monitoring
    Murphy, Benjamin
    Morgan, Sean
    Luy, Edward
    Creelman, Joshua
    Sieben, Vincent
    [J]. OCEANS 2019 MTS/IEEE SEATTLE, 2019,
  • [5] THE ROLE OF LAB-ON-A-CHIP DEVICE IN HEALTH CARE
    Patel, Sweta
    Maheshwari, Aishaani
    Chandra, Amrish
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2016, 7 (04): : 1391 - 1395
  • [6] Development of an "lab-on-a-chip" device using electrochemistry
    Arau, Victoria
    Cheng, Yu-Hsuan
    Basuray, Sagnik
    Chatterjee, Sayandev
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [7] Portable capillary electrophoresis-system for on-site food analysis with lab-on-a-chip based contactless conductivity detection
    Gaertner, Claudia
    Sewart, Rene
    Klemm, Richard
    Becker, Holger
    [J]. SENSING TECHNOLOGIES FOR GLOBAL HEALTH, MILITARY MEDICINE, AND ENVIRONMENTAL MONITORING IV, 2014, 9112
  • [8] Rapid On-site Monitoring of Organophosphorus Insecticide Chlorpyrifos Residue Using Simple Plastic Lab-on-a-Chip
    Chaumpluk, P.
    Janduang, T.
    [J]. ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES XIV, 2017, 10215
  • [9] Lab-on-a-chip device for food quality control and safety
    Rafiq, Syed Mansha
    Majumder, Reshab
    Joshi, Deepak
    Dar, Aamir Hussain
    Dash, Kshirod Kumar
    Pandey, Vinay Kumar
    Sidiqi, Urba Shafi
    [J]. FOOD CONTROL, 2024, 164
  • [10] Water analysis in a lab-on-a-chip system
    Freimuth, Herbert
    von Germar, Frithjof
    Frese, Ines
    Nahrstedt, Elzbieta
    Kuepper, Michael
    Schenk, Rainer
    Baser, Bjoern
    Ott, Johannes
    Drese, Klaus
    Detemple, Peter
    Doll, Theodor
    [J]. MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS IV, 2006, 6112