Flow seeding with an air nebulizer

被引:0
|
作者
D. Durox
S. Ducruix
F. Lacas
机构
[1] Laboratoire EM2C. CNRS/ECP,
[2] Grande Voie des Vignes,undefined
[3] F-92295 Châtenay-Malabry. France,undefined
来源
Experiments in Fluids | 1999年 / 27卷
关键词
Viscosity; Surface Tension; Pure Water; Droplet Size; Reactive Flow;
D O I
暂无
中图分类号
学科分类号
摘要
 In the framework of studies on anemometric measurements or tomographic visualizations, the seeding of a reactive flow by a nebulizer has been analyzed. In order to determine the performances of this apparatus, different liquids have been tested to evaluate the influence of their physical properties on the droplets size distribution. Measurements have been made using a Phase Doppler Anemometer. It is shown that the mean D10 diameter lies between 2 and 3 μm, whatever the liquid may be, except pure water, and that, within a certain range, viscosity and surface tension have little influence on the size distribution. The ability of these liquids to seed reactive mixture is also discussed and especially their interaction in premixed flames.
引用
收藏
页码:408 / 413
页数:5
相关论文
共 50 条
  • [1] Flow seeding with an air nebulizer
    Durox, D
    Ducruix, S
    Lacas, F
    EXPERIMENTS IN FLUIDS, 1999, 27 (05) : 408 - 413
  • [2] Seeding of high temperature air flow
    Rusch, D.
    Kempe, A.
    Roesgen, T.
    EXPERIMENTS IN FLUIDS, 2007, 42 (05) : 761 - 765
  • [3] Seeding of high temperature air flow
    D. Rusch
    A. Kempe
    T. Roesgen
    Experiments in Fluids, 2007, 42 : 761 - 765
  • [4] DESIGN AND CHARACTERIZATION OF A LOW AIR-FLOW NEBULIZER
    ESMEN, NA
    WEYEL, DA
    FARROKH, SRB
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1982, 43 (12): : 934 - 937
  • [5] Medication nebulizer performance - Effects of diluent volume, nebulizer flow, and nebulizer brand
    Hess, D
    Fisher, D
    Williams, P
    Pooler, S
    Kacmarek, RM
    CHEST, 1996, 110 (02) : 498 - &
  • [6] A novel seeding technique for the flow visualization of pressurized air flows
    Meares, AJ
    Holdo, AE
    Wakes, SJ
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (10) : 1183 - 1186
  • [7] SIMPLIFYING THE ASSESSMENT OF PATIENTS WITH CHRONIC AIR-FLOW LIMITATION FOR HOME NEBULIZER THERAPY
    GOLDMAN, JM
    TEALE, C
    MUERS, MF
    RESPIRATORY MEDICINE, 1992, 86 (01) : 33 - 38
  • [8] Numerical simulation of air flow and medical-aerosol distribution in an innovative nebulizer hood
    Shakked, T
    Katoshevski, D
    Broday, DM
    Amirav, I
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2005, 18 (02): : 207 - 217
  • [9] CEREAL SEEDING BY AIR
    不详
    FARM QUARTERLY, 1969, 24 (02): : 52 - &
  • [10] CLEAR AIR SEEDING
    DETWILER, AG
    VONNEGUT, B
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1979, 60 (05) : 550 - 550