Comparison of narcotrend index, bispectral index, spectral and entropy parameters during induction of propofol-remifentanil anaesthesia

被引:46
|
作者
Schultz A. [1 ,3 ]
Siedenberg M. [2 ]
Grouven U. [1 ]
Kneif T. [1 ]
Schultz B. [2 ]
机构
[1] Department of Medical Informatics and Biometry, Klinikum Region Hannover, Hannover
[2] Clinic of Anaesthesiology and Intensive Care Medicine, Hannover Medical School, Hannover
[3] Arbeitsgruppe Informatik/Biometrie, Klinikum Region Hannover Oststadt- Heidehaus, Medizinische Hochschule Hannover, D-30659 Hannover
关键词
Anaesthesia; Awareness; Bispectral Index; Entropy parameters; Gender; Narcotrend Index; Spectral parameters;
D O I
10.1007/s10877-008-9111-6
中图分类号
学科分类号
摘要
Objective. This study investigated the suitability of various electroencephalogram (EEG) parameters to describe anaesthetic drug effects in propofol-remifentanil anaesthesia. The investigated parameters were the Narcotrend® Index (NI), the Bispectral Index™ (BIS™), and standard spectral and entropy parameters. Additionally, it was investigated whether the effect of a fixed dosage of propofol on the attained depth of hypnosis during induction of anaesthesia is different in male and female patients. Methods. Standardized inductions of anaesthesia in 10 male and 10 female patients (ASA status I or II, 15-75 years) were analysed. All patients received 4 mg propofol/kg over 6 min followed by 4 mg/kg/h. For analgesia, patients received 0.3 μg/kg/min remifentanil starting 2 min before propofol application. For EEG monitoring, the Narcotrend and the Aspect A-2000 Bispectral Index monitor were used simultaneously. Data from start of propofol injection until 1 min after the end of the induction period (420 s) were used for statistical analysis. EEG parameters were evaluated every 10 s. Results. The Narcotrend® Index and the Bispectral Index™ had the highest mean correlations with the calculated propofol effect-site concentration and were able to distinguish stages from the awake state or the near awake state and stages of deep hypnosis. On the Narcotrend scale, more data points are available for levels of anaesthesia with relevance for maintenance of anaesthesia. The BIS values at the first occurrence of burst suppression were significantly higher than the corresponding NI values. During induction of anaesthesia, the same dosages of propofol (per kg body weight) given to men and women did not show different effects on the EEG. Conclusions. NI and BIS are superior to-spectral and entropy parameters in describing changes of propofol concentration during induction of propofol-remifentanil anaesthesia. © Springer Science+Business Media B.V. 2008.
引用
收藏
页码:103 / 111
页数:8
相关论文
共 50 条
  • [1] Comparison of Alaris AEP index and bispectral index during propofol-remifentanil anaesthesia
    Kreuer, S
    Bruhn, J
    Larsen, R
    Hoepstein, M
    Wilhelm, W
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (03) : 336 - 340
  • [2] Correlation of Narcotrend Index, entropy measures, and spectral parameters with calculated propofol effect-site concentrations during induction of propofol-remifentanil anaesthesia
    Grouven U.
    Beger F.A.
    Schultz B.
    Schultz A.
    [J]. Journal of Clinical Monitoring and Computing, 2004, 18 (04) : 231 - 240
  • [3] Comparability of Narcotrend index and bispectral index during propofol anaesthesia
    Bialas, P.
    Wilhelm, W.
    Grundmann, U.
    Larsen, R.
    Bruhn, J.
    Kreuer, S.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 30 - 31
  • [4] Comparability of Narcotrend™ index and bispectral index during propofol anaesthesia
    Kreuer, S
    Bruhn, J
    Larsen, R
    Bialas, P
    Wilhelm, W
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2004, 93 (02) : 235 - 240
  • [5] SNAP-index and Bispectral index during induction of anaesthesia propofol and remifentanil
    Schmidt, GN
    Standl, T
    Lankenau, G
    Hellstern, A
    Hipp, C
    Bischoff, P
    [J]. ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2004, 39 (05): : 286 - 291
  • [6] Ketamine has no effect on bispectral index during stable propofol-remifentanil anaesthesia
    Faraoni, D.
    Salengros, J. -C.
    Engelman, E.
    Ickx, B.
    Barvais, L.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (03) : 336 - 339
  • [7] The Narcotrend™– a new EEG monitor designed to measure the depth of anaesthesia A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesiaA comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia
    S. Kreuer
    A. Biedler
    R. Larsen
    S. Schoth
    S. Altmann
    W. Wilhelm
    [J]. Der Anaesthesist, 2001, 50 : 921 - 925
  • [8] SNAP index and Bispectral Index during propofol/remifentanil anaesthesia
    Bischoff, P.
    Schmidt, G.
    Standl, T.
    Lankenau, G.
    Hipp, C.
    Esch, J. Schulte Am
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 36 - 36
  • [9] Narcotrend® and Bispectral Index® monitor are superior to classic electroencephalographic parameters for the assessment of anesthetic states during propofol-remifentanil anesthesia
    Schmidt, GN
    Bischoff, P
    Standl, T
    Jensen, K
    Voigt, M
    Esch, JSA
    [J]. ANESTHESIOLOGY, 2003, 99 (05) : 1072 - 1077
  • [10] Variation of bispectral index monitoring in paediatric patients undergoing propofol-remifentanil anaesthesia
    Liu, J. S.
    Zhang, J. M.
    Yue, Y.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (10) : 821 - 825