Performance of extended end-plate bolted connections subjected to static and blast-like loads

被引:0
|
作者
Osman A.A. [1 ]
Mourad S.A. [1 ]
机构
[1] Faculty of Engineering, Cairo University, Cairo
来源
关键词
Blast load; Extended end-plate connection; Finite element analysis; Pressure-impulse diagram; Pretensioned bolts;
D O I
10.1186/s44147-021-00001-3
中图分类号
学科分类号
摘要
In this study, numerical models were developed to predict the behavior of steel extended end-plate moment connections subjected to static and blast-like loading. Two types of extended end-plate connections were considered, stiffened, and unstiffened, with pretensioned bolts. The models were verified by comparing the results with published experimental data. The models were used to compute the moment-rotation curves for the connection under static loading, and then under different blast durations. The pressure impulse diagram and the energy dissipation for the connection under dynamic loading were determined. The failure modes were examined, and the numerical results were compared with the simplified models presented in codes and standards. Improvement in the performance of the connection by adding one or two stiffeners was demonstrated. For the configuration studied, introducing a stiffener increased plastic dissipation energy for blast loading by 45% compared to the unstiffened connection, whereas under static loading, the plastic energy dissipation for stiffened connection, SC2, was higher than the unstiffened connection by 30%. A conservative estimate for the dynamic increase factor (DIF) was found to be 1.2 for steel yield stress and 1.05 for bolt failure. © 2021, The Author(s).
引用
收藏
相关论文
共 50 条
  • [1] Behavior of extended end-plate bolted connections subjected to monotonic and cyclic loads
    ElSabbagh, Ashraf
    Sharaf, Tarek
    Nagy, Salah
    ElGhandour, Mohammed
    ENGINEERING STRUCTURES, 2019, 190 : 142 - 159
  • [2] Progressive Collapse Resistance of Bolted Extended End-Plate Moment Connections
    Samad Barmaki
    Mohammad R. Sheidaii
    Omid Azizpour
    International Journal of Steel Structures, 2020, 20 : 1165 - 1179
  • [3] Progressive Collapse Resistance of Bolted Extended End-Plate Moment Connections
    Barmaki, Samad
    Sheidaii, Mohammad R.
    Azizpour, Omid
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (04) : 1165 - 1179
  • [4] Behavior of I-beam bolted extended end-plate moment connections
    Dessouki, Abdelrahim Khalil
    Youssef, Ahmed Hassan
    Ibrahim, Mohamed Mostafa
    AIN SHAMS ENGINEERING JOURNAL, 2013, 4 (04) : 685 - 699
  • [5] Performance Assessment of Bolted Extended End-Plate Moment Connections Constructed from Grade St-37 Steel Subjected to Fatigue
    Ghaderi, Mohsen
    Gerami, Mohsen
    Vahdani, Reza
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2020, 32 (05)
  • [6] FE modelling of bolted steel end-plate moment connections subjected to a standard fire
    Salem, O.
    Hadjisophocleous, G.
    Zalok, E.
    TUBULAR STRUCTURES XIV, 2012, : 615 - 622
  • [7] Nonlinear response of bolted end-plate steel connections
    Amiri, GG
    Jamalzadeh, M
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 77 - 82
  • [8] Influence of initial imperfection on the behaviour of extended bolted end-plate connections for portal frames
    Chen, Shiming
    Du, Gang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (02) : 211 - 220
  • [9] Seismic behaviour of high-strength steel bolted extended end-plate connections
    Hu, Fangxin
    Wang, Zhan
    ce/papers, 2023, 6 (3-4) : 639 - 644
  • [10] Experimental investigation of bolted stiffened end-plate and bolted flange-plate connections
    Yilmaz, Orkun
    Bekiroglu, Serkan
    Alemdar, Fatih
    Arslan, Guray
    Sevim, Barn
    Ayvaz, Yusuf
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2019, 16 (03):