Investigation of natural ventilation performance of large space circular coal storage dome

被引:0
|
作者
Yaohua Hou
Chao Chen
Yu Zhou
Zhixiang Yang
Shen Wei
机构
[1] Beijing University of Technology,Key Laboratory of Green Built Environment and Energy Efficient Technology
[2] China People’s Police University,Department of Fire Commanding
[3] Huadian Heavy Industries Co.,Bartlett School of Construction and Project Management
[4] Ltd.,undefined
[5] University College London,undefined
来源
Building Simulation | 2021年 / 14卷
关键词
large space circular coal storage dome; natural ventilation performance; opening mode; computational fluid dynamics; evaluation indicator;
D O I
暂无
中图分类号
学科分类号
摘要
Large space circular coal storage dome (LSCCSD) offers an environmental and dependable alternative to open stockpiles, and it has been consequently widely applied in China. However, due to the lack of scientific guidelines, its natural ventilation performance is lower than expected. Natural ventilation potential strongly depends on the roof geometry and opening mode, which have not yet been investigated for LSCCSD. This paper presents a detailed evaluation of the impact of dome geometry (rise span ratio), opening height, and opening modes on the ventilation performance of LSCCSD. The evaluation is based on computational fluid dynamics (CFD) methods and is validated by available wind tunnel testing. We employed three evaluation indicators, which are wind pressure coefficient, effective ventilation rate, and wind speed ratio. The results demonstrate that the rise span ratio has a significant effect on the wind pressure difference and the effective ventilation rate increases by approximately 9%–42% with a single-annular opening. When double-annular openings are set in a strong positive pressure zone, the effective ventilation rate increases by 100% and the average wind speed ratio increases by 50%. When it is compared with single one with similar opening height, the effective ventilation rate increases by 25%. The optimum natural ventilation performance for LSCCSD is achieved at a rise span ratio of 0.37. In addition, the lateral middle opening is kept higher than the ridge top of the coal pile. The proposed evaluation approach and design parameters provided instructive information in the building design and ventilation control for LSCCSDs.
引用
下载
收藏
页码:1077 / 1093
页数:16
相关论文
共 50 条
  • [1] Investigation of natural ventilation performance of large space circular coal storage dome
    Hou, Yaohua
    Chen, Chao
    Zhou, Yu
    Yang, Zhixiang
    Wei, Shen
    BUILDING SIMULATION, 2021, 14 (04) : 1077 - 1093
  • [2] Analysis of Natural Ventilation Design in Large Space of Railway Station
    Han, Xiaolin
    Zhang, Hui
    Zhu, Ting
    Wang, Li
    2020 6TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2020, 508
  • [3] Experimental investigation of effect of ventilation strategies on the performance of cold storage
    Bishnoi, Rajkumar
    Aharwal, K. R.
    HEAT TRANSFER, 2024, 53 (02) : 346 - 362
  • [4] Natural ventilation performance of a large greenhouse equipped with insect screens
    Majdoubi, H.
    Boulard, T.
    Hanafi, A.
    Bekkaoui, A.
    Fatnassi, H.
    Demrati, H.
    Nya, M.
    Bouirden, L.
    TRANSACTIONS OF THE ASABE, 2007, 50 (02) : 641 - 650
  • [5] Natural ventilation performance of a large greenhouse equipped with insect screens
    Thermodynamics and Energetics Laboratory, Department of Physics, Ibn Zohr University, Agadir, Morocco
    不详
    不详
    不详
    不详
    Trans. ASABE, 2007, 2 (641-650):
  • [6] Prediction of natural and hybrid ventilation performance used for fire-induced smoke control in a large single space
    Tong, Yan
    Huo, Dekai
    Zhu, Peigen
    Niu, Xiaofeng
    FIRE SAFETY JOURNAL, 2018, 100 : 20 - 31
  • [7] A performance assessment of an office space with displacement, personal, and natural ventilation systems
    Taheri, Mahnameh
    Schuss, Matthias
    Fail, Alfred
    Mahdavi, Ardeshir
    BUILDING SIMULATION, 2016, 9 (01) : 89 - 100
  • [8] A performance assessment of an office space with displacement, personal, and natural ventilation systems
    Mahnameh Taheri
    Matthias Schuss
    Alfred Fail
    Ardeshir Mahdavi
    Building Simulation, 2016, 9 : 89 - 100
  • [9] Natural ventilation and microclimatic performance of a large-scale banana greenhouse
    Demrati, H
    Boulard, T
    Bekkaoui, A
    Bouirden, L
    JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 2001, 80 (03): : 261 - 271
  • [10] Investigation on temperature control performance of an underground confined space under ventilation
    Jin, Ting
    Zhang, Zujing
    Ge, Liang
    Liang, Xing
    Wu, Hongwei
    Zhou, Jiri
    Mao, Ruiyong
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 50