CatBoost-based improved detection of P-wave changes in sinus rhythm and tachycardia conditions: a lead selection study

被引:0
|
作者
N. Prasanna Venkatesh
R. Pradeep Kumar
Bala Chakravarthy Neelapu
Kunal Pal
J. Sivaraman
机构
[1] National Institute of Technology Rourkela,Department of Biotechnology and Medical Engineering
[2] Jaiprakash Hospital and Research Centre,Department of Cardiac Sciences
关键词
Atrial lead system ; Automated lead selection; CatBoost model; Improved atrial activity; Optimal leads; P-wave changes;
D O I
暂无
中图分类号
学科分类号
摘要
Examining P-wave morphological changes in Electrocardiogram (ECG) is essential for characterizing atrial arrhythmias. However, standard 12-lead ECGsuffer from diagnostic redundancy due to low signal-to-noise ratio of P-waves. To address this issue, various optimal leads have been proposed for improved atrial activity recording, but the right selection among these leads is crucial for enhancing diagnostic efficacy. This study proposes an automated lead selection technique using the CatBoost machine learning (ML) model to improve the detection of P-wave changes among optimal bipolar leads under different heart rates. ECGs were obtained from healthy participants with a mean age of 25 ± 3.81 years (34% women), including 114 in sinus rhythm (SR) and 38 in sinus tachycardia (ST). The recordings were made using a newly designed atrial lead system (ALS), standard limb lead (SLL), modified limb lead (MLL), modified Lewis lead (LLM) and P-lead. P-wave features and Atrioventricular (AV) ratio were extracted for statistical analysis and ML classification. The optimum ML model was chosen to identify the best-performing optimal lead, which was selected based on the SLL metrics among different ML classifiers. CatBoost was found to outperform the other ML models in SLL-II with the highest accuracy and sensitivity of 0.82 and 0.90, respectively. The CatBoost model, amid other optimal leads, gave the best results for AL-I and AL-II (0.86 and 0.83 in accuracy and 0.91 and 0.93 in sensitivity). The developed CatBoost model selected AL-I and AL-II as the top two best-performing optimal leads for the enhanced acquisition of P-wave changes, which may be useful for diagnosing atrial arrhythmias.
引用
收藏
页码:925 / 944
页数:19
相关论文
共 15 条
  • [1] CatBoost-based improved detection of P-wave changes in sinus rhythm and tachycardia conditions: a lead selection study
    Venkatesh, N. Prasanna
    Kumar, R. Pradeep
    Neelapu, Bala Chakravarthy
    Pal, Kunal
    Sivaraman, J.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) : 925 - 944
  • [2] Pulmonary Vein Tachycardia: Is the Sinus Rhythm P-wave Useful?
    Kistler, Peter M.
    Teh, Andrew W.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (02): : 134 - 136
  • [3] Optimal lead selection for the study of the P wave in sinus rhythm
    Climent, A
    Guillem, MS
    Millet, J
    Mora, C
    Ruiz, R
    Chorro, FJ
    Computers in Cardiology 2005, Vol 32, 2005, 32 : 195 - 198
  • [4] A NEW ATRIAL LEAD WITH IMPROVED STABILITY AND P-WAVE DETECTION
    HUGHES, HC
    BERTOLET, RD
    BROWNLEE, RR
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (04): : 726 - 734
  • [5] P-Wave Amplitude and PR Changes in Patients With Inappropriate Sinus Tachycardia: Findings Supportive of a Central Mechanism
    Field, Michael E.
    Donateo, Paolo
    Bottoni, Nicola
    Iori, Matteo
    Brignole, Michele
    Kipp, Ryan T.
    Kopp, Douglas E.
    Leal, Miguel A.
    Eckhardt, Lee L.
    Wright, Jennifer M.
    Walsh, Kathleen E.
    Page, Richard L.
    Hamdan, Mohamed H.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (09):
  • [6] Multiple P-wave Morphologies in Paroxysmal Atrial Fibrillation Patients During Sinus Rhythm: A Simulation Study
    Filos, Dimitris
    Korosoglou, Paschalis
    Tachmatzidis, Dimitris
    Maglaveras, Nicos
    Vassilikos, Vassilios
    Chouvarda, Ioanna
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [7] Detection of vectorcardiographic P-wave alterations in patients with paroxysmal atrial fibrillation in sinus rhythm - a novel diagnostic tool?
    Brasier, N.
    Kolbitsch, T.
    Tabord, A.
    Knobeloch, J.
    Engelter, S.
    Kuehne, M.
    Conen, D.
    Eckstein, J.
    EUROPEAN HEART JOURNAL, 2015, 36 : 88 - 88
  • [8] Detection of patients with hypertrophic cardiomyopathy at risk for paroxysmal atrial fibrillation during sinus rhythm by P-wave dispersion
    Köse, S
    Aytemir, K
    Sade, E
    Can, I
    Özer, N
    Amasyali, B
    Aksöyek, S
    Övünc, K
    Özmen, F
    Atalar, E
    Isik, E
    Kes, S
    Demirtas, E
    Oto, A
    CLINICAL CARDIOLOGY, 2003, 26 (09) : 431 - 434
  • [9] The Impact of Pulmonary Vein Anatomy on P-Wave Appearance during Sinus Rhythm: Cardiac Computed Tomography Study
    Verhovceva, Viktorija
    Zvaigzne, Ligita
    Lacis, Romans
    Kalejs, Oskars
    DIAGNOSTICS, 2023, 13 (18)
  • [10] STUDY OF P-WAVE MORPHOLOGY IN LEAD V1 DURING SUPRAVENTRICULAR TACHYCARDIA FOR LOCALIZING THE REENTRANT CIRCUIT
    BREMBILLAPERROT, B