Ultrasound is one of the preferred modalities for localization of abnormal parathyroids. Accuracy of ultrasound is technician-dependent. This study was undertaken to determine the accuracy of surgeon-performed ultrasound (SPU) for the localization of parathyroid tumors in comparison to radiology-performed ultrasound (RPU) and nuclear scintigraphy (NS). In this series 74 consecutive patients with untreated primary hyperparathyroidism underwent SPU at the initial clinic visit; 21 of these patients did not undergo surgery and are excluded from the analysis. Of the 53 patients remaining, RPU was obtained in 26, and 52 patients underwent NS. Directed parathyroidectomy was performed with use of the intraoperative parathyroid hormone assay (IOPTH). In all, 46 patients had a single adenoma as indicated by IOPTH and final pathology. Two patients had double gland disease, and 5 patients had multi-gland hyperplasia. The sensitivity of SPU was 82% and the specificity was 90% in detecting the diseased glands on the correct side (right versus left). The sensitivity for RPU was 42% and the specificity was 92% (n = 26). The sensitivity of NS was 44% and the specificity was 98% (n = 52). In only one case did RPU or NS detect a gland not found by SPU. SPU can be done with accuracy comparable to other ultrasound series in the literature, and it may be superior to RPU or NS in some institutions. It is important for surgeons to be aware of local institutional expertise when relying on RPU and NS during preoperative evaluation prior to directed parathyroidectomy.
引用
收藏
页码:1122 / 1126
页数:4
相关论文
共 50 条
  • [1] Accuracy of surgeon-performed ultrasound in parathyroid localization
    Van Husen, R
    Kim, LT
    WORLD JOURNAL OF SURGERY, 2004, 28 (11) : 1122 - 1126
  • [2] The Accuracy of Surgeon-Performed Preoperative Parathyroid Ultrasound Localization for Renal Hyperparathyroidism Patient
    Lai, J. H.
    Mahno, N. E.
    Latar, Md N. H.
    Muhammad, R.
    Suhaimi, Abdullah S. N.
    IIUM MEDICAL JOURNAL MALAYSIA, 2022, 21 (02): : 88 - 94
  • [3] Parathyroid adenoma localization: Surgeon-performed ultrasound versus sestamibi
    Steward, David L.
    Danielson, Gregory P.
    Afman, Chad E.
    Welge, Jeffrey A.
    LARYNGOSCOPE, 2006, 116 (08): : 1380 - 1384
  • [4] Surgeon-performed ultrasound improves localization of abnormal parathyroid glands
    Solorzano, CC
    Lee, TM
    Ramirez, MC
    Carneiro, DM
    Irvin, GL
    AMERICAN SURGEON, 2005, 71 (07) : 557 - 562
  • [5] Surgeon-performed ultrasound: A single institution experience in parathyroid localization
    Jabiev, Azad A.
    Lew, John I.
    Solorzano, Carmen C.
    SURGERY, 2009, 146 (04) : 569 - 577
  • [6] Accuracy of surgeon-performed trauma ultrasound
    Lazzaron, AR
    ARCHIVES OF SURGERY, 1998, 133 (11) : 1254 - 1254
  • [7] Surgeon-performed ultrasound improves localization of abnormal parathyroid glands - Discussion
    Roe, SM
    Britt, LD
    Lee, TM
    Solorzano, C
    AMERICAN SURGEON, 2005, 71 (07) : 562 - 563
  • [8] Use of surgeon-performed office ultrasound and parathyroid fine needle aspiration for complex parathyroid localization
    Stephen, AE
    Milas, M
    Garner, CN
    Wagner, KE
    Siperstein, AE
    SURGERY, 2005, 138 (06) : 1143 - 1150
  • [9] Accuracy of surgeon-performed gallbladder ultrasound - Discussion
    Macho, JR
    Sirginsad, H
    Mansour, MA
    Brunicardi, FC
    AMERICAN JOURNAL OF SURGERY, 1999, 178 (06): : 478 - 478
  • [10] Accuracy of surgeon-performed gallbladder ultrasound - Closing
    Fang, R
    AMERICAN JOURNAL OF SURGERY, 1999, 178 (06): : 478 - 479