in vitro evaluation of intragastric pco2 measurement by air tonometry

被引:0
|
作者
Jeroen J. Kolkman
Loek J. Zwaarekant
Klaas Boshuizen
A. B. Johan Groeneveld
Stephan G. M. Meuwissen
机构
[1] Academic Hospital “Vrije Universiteit”,Department of Gastroenterology
[2] Academic Hospital “Vrije Universiteit”,Department of Clinical Physics & Medical Technology
[3] Academic Hospital “Vrije Universiteit”,Department of Medical Intensive Care Unit
来源
关键词
tonometry; regional PCO; gastrointestinal tract; ischemia; validation;
D O I
暂无
中图分类号
学科分类号
摘要
Objective. To assess the in vitro performance of a new device,the Tonocap®, for semi-continuous air tonometry of regionalPCO2 in the gastrointestinal tract. Methods. Thetonometer consists of an air filled balloon-tipped catheter, connected to aprototype Tonocap® system. The tonometer was placed in saline baths atsteady-state PCO2’s ranging from 0 to 105 torr, toevaluate bias, precision and reproducibility to PCO2measurements. The response time was defined as the time needed to detect 95%of an instantaneous change in bath PCO2. Results. Thebias of the PCO2 measurement (mean ± SD) was−2 ± 2% and reproducibility (coefficient ofvariation) was 2 ± 1%. The response time was 19 ± 2 min.Conclusions. Tonocap® air tonometry is simple andeliminates most sources of error associated with conventional salinetonometry. The bias, precision, reproducibility and response time invitro are consistent with a clinically reliable device.
引用
收藏
页码:115 / 119
页数:4
相关论文
共 50 条
  • [1] In vitro evaluation of intragastric PCO2 measurement by air tonometry
    Kolkman, JJ
    Zwaarekant, LJ
    Boshuizen, K
    Groeneveld, ABJ
    Meuwissen, SGM
    [J]. JOURNAL OF CLINICAL MONITORING, 1997, 13 (02) : 115 - 119
  • [2] Effect of temperature on gastric intramucosal PCO2 measurement by saline and air tonometry
    Hiroshi Dohgomori
    Kazuhiro Arikawa
    Yuichi Kanmura
    [J]. Journal of Anesthesia, 2003, 17 (4) : 284 - 286
  • [3] Effect of gastric feeding on intragastric Pco2 tonometry in healthy volunteers
    Kolkman, JJ
    Groeneveld, ABJ
    Meuwissen, SGM
    [J]. JOURNAL OF CRITICAL CARE, 1999, 14 (01) : 34 - 38
  • [4] Type of solution and PCO2 measurement errors during tonometry
    Kolkman, JJ
    Zwarekant, LJ
    Boshuizen, K
    Groeneveld, ABJ
    Steverink, PJGM
    Meuwissen, SGM
    [J]. INTENSIVE CARE MEDICINE, 1997, 23 (06) : 658 - 663
  • [5] Type of solution and PCO2 measurement errors during tonometry
    J. J. Kolkman
    L. J. Zwarekant
    K. Boshuizen
    A. B. J. Groeneveld
    P. J. G. M. Steverink
    S. G. M. Meuwissen
    [J]. Intensive Care Medicine, 1997, 23 : 658 - 663
  • [6] Factors affecting gastrointestinal luminal PCO2 tonometry
    A. B. J. Groeneveld
    J. J. Kolkman
    [J]. Intensive Care Medicine, 1999, 25 : 249 - 251
  • [7] Factors affecting gastrointestinal luminal PCO2 tonometry
    Groeneveld, ABJ
    Kolkman, JJ
    [J]. INTENSIVE CARE MEDICINE, 1999, 25 (03) : 249 - 251
  • [8] MEASUREMENT OF BRAIN PCO2 AND INVIVO VALIDATION OF THE PCO2 MICROELECTRODE
    HOGG, RJ
    PUCCACO, LR
    CARTER, NW
    LAPTOOK, AR
    KOKKO, JP
    [J]. CLINICAL RESEARCH, 1983, 31 (05): : A861 - A861
  • [9] MEASUREMENT OF PCO2 IN EXUDATES
    HARICHAUX, P
    FREVILLE, M
    LIENARD, J
    DENOEUX, JP
    MOLINE, J
    [J]. ANNALES DE BIOLOGIE CLINIQUE, 1970, 28 (05) : 401 - +
  • [10] Does gastric juice pH influence tonometric Pco2, measured by automated air tonometry?
    Brinkmann, A
    Glasbrenner, B
    Vlatten, A
    Eberhardt, H
    Geldner, G
    Radermacher, P
    Georgieff, M
    Wiedeck, H
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (05) : 1150 - 1152