Stopping mechanism for capsule endoscope using electrical stimulus

被引:0
|
作者
Sang Hyo Woo
Tae Wan Kim
Jin Ho Cho
机构
[1] Kyungpook National University,School of Electrical Engineering and Computer Science
[2] Kyungpook National University,Department of Physiology, College of Veterinary Medicine
关键词
Capsule endoscope; Electrical stimulus; Stopping; Small intestine;
D O I
暂无
中图分类号
学科分类号
摘要
An ingestible capsule, which has the ability to stop at certain locations in the small intestine, was designed and implemented to monitor intestinal diseases. The proposed capsule can contract the small intestine by using electrical stimuli; this contraction causes the capsule to stop when the maximum static frictional force (MSFF) is larger than the force of natural peristalsis. In vitro experiments were carried out to verify the feasibility of the capsule, and the results showed that the capsule was successfully stopped in the small intestine. Various electrodes and electrical stimulus parameters were determined on the basis of the MSFF. A moderate increment of the MSFF (12.7 ± 4.6 gf at 5 V, 10 Hz, and 5 ms) and the maximum increment of the MSFF (56.5 ± 9.77 gf at 20 V, 10 Hz, and 5 ms) were obtained, and it is sufficient force to stop the capsule.
引用
收藏
页码:97 / 102
页数:5
相关论文
共 50 条
  • [1] Stopping mechanism for capsule endoscope using electrical stimulus
    Woo, Sang Hyo
    Kim, Tae Wan
    Cho, Jin Ho
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (01) : 97 - 102
  • [2] Micro Tattooing Mechanism for the Capsule Endoscope
    Joe, Seonggun
    Lee, Dongkyu
    Kang, Byungjeon
    Park, Jong-Oh
    Kim, Byungkyu
    [J]. 2017 14TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2017, : 830 - 831
  • [3] Design of triggering mechanism for capsule endoscope
    Joe, Seonggun
    Kang, Hyeongseok
    Lee, Dongkyu
    Kang, Byungjoen
    Park, Jong-Oh
    Kim, Byungkyu
    [J]. 2018 18TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2018, : 695 - 696
  • [4] Design of a Steering Mechanism for a Tethered Capsule Endoscope
    Ye, Xianming
    Hasson, Cyril
    Yoon, W. Jong
    Cabibihan, John-John
    [J]. PROCEEDINGS OF THE 2015 7TH IEEE INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS (CIS) AND ROBOTICS, AUTOMATION AND MECHATRONICS (RAM), 2015, : 234 - 238
  • [5] Magnetic actuation and guidance mechanism for active capsule endoscope
    Wang, Xiaona
    Meng, Max Q. -H.
    [J]. 2007 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS, VOLS 1-3, 2007, : 689 - +
  • [6] Implemented edge shape of an electrical stimulus capsule
    Woo, Sang Hyo
    Kim, Tae Wan
    Lee, Jyung Hyun
    Kim, Pil Un
    Won, Chui Ho
    Cho, Jin Ho
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (01): : 59 - 65
  • [7] Retrieval of a video capsule endoscope by using a double-balloon endoscope
    Al-toma, A
    Hadithi, M
    Heine, D
    Jacobs, M
    Mulder, C
    [J]. GASTROINTESTINAL ENDOSCOPY, 2005, 62 (04) : 613 - 613
  • [8] On localizing a Capsule Endoscope using Magnetic Sensors
    Moussakhani, Babak
    Ramstad, Tor
    Flam, John T.
    Balasingham, Ilangko
    [J]. 2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 4058 - 4062
  • [9] A Locomotion Mechanism with External Magnetic Guidance for Active Capsule Endoscope
    Wang, Xiaona
    Meng, Max Q. -H.
    Chen, Xijun
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4375 - 4378
  • [10] A magnetic stereo-actuation mechanism for active capsule endoscope
    Wang, Xiaona
    Meng, Max Q. -H.
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2811 - 2814