Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera

被引:0
|
作者
Hendrik Everaert
Christian Vanhove
Tony Lahoutte
Kristoff Muylle
Vicky Caveliers
Axel Bossuyt
Philippe R. Franken
机构
[1] Free University of Brussels (AZ VUB),Division of Nuclear Medicine, University Hospital
关键词
F-FDG PET; LSO; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
Reducing the acquisition time of whole-body fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) (corrected for attenuation) is of major importance in clinical practice. With the introduction of lutetium oxyorthosilicate (LSO), the acquisition time can be dramatically reduced, provided that patients are injected with larger amounts of tracer and/or the system is operated in 3D mode. The aim of this study was to determine the optimal dose of 18F-FDG required in order to achieve good-to-excellent image quality when a "3-min emission, 2-min transmission/bed position" protocol is used for an LSO PET camera. A total of 218 consecutive whole-body 18F-FDG PET studies were evaluated retrospectively. After excluding patients with liver metastases, hyperglycaemia and paravenous injections, the final study population consisted of 186 subjects (112 men, 74 women, age 59±15 years). Patients were injected with an activity of 18F-FDG ranging from 2.23 to 15.21 MBq/kg. Whole-body images corrected for attenuation (3 min emission, 2 min transmission/bed position) were acquired with an LSO PET camera (Ecat Accel,Siemens) 60 min after tracer administration. Patients were positioned with their arms along the body. Image reconstruction was done iteratively and a post-reconstruction filter was applied. Image quality was scored visually by two independent observers using a five-point scoring scale (poor, reasonable, good, very good, excellent). In addition, the coefficient of variability (COV) was measured in a region of interest over the liver in order to quantify noise. Of the images obtained in 118 patients injected with ≥8 MBq/kg 18F-FDG, 92% and 90% were classified as good, very good or excellent by observer 1 and observer 2, respectively. The COV averaged 10.63%±3.19% for doses ≥8 MBq/kg and 16.46%±5.14% for doses <8 MBq/kg. Administration of an 18F-FDG dose of ≥8 MBq/kg results in images of good to excellent quality in the vast majority of patients when using an LSO PET camera and applying a 3-min emission, 2-min transmission/bed position acquisition protocol. At lower doses, a rapid decline in image quality and increasing noise are observed. Alternative protocols should be adopted in order to compensate for the loss in image quality when doses <8 MBq/kg are used.
引用
收藏
页码:1615 / 1619
页数:4
相关论文
共 50 条
  • [1] Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera
    Everaert, H
    Vanhove, C
    Lahoutte, T
    Muylle, K
    Caveliers, V
    Bossuyt, A
    Franken, PR
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) : 1615 - 1619
  • [2] Dose of 18FDG required for whole body PET using an LSO-PET camera.
    Everaert, H
    Vanhove, C
    Muylle, K
    Lahoutte, T
    Caveliers, V
    Franken, PR
    Bossuyt, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 282P - 282P
  • [3] Methods of CT Dose Estimation in Whole-Body 18F-FDG PET/CT
    Inoue, Yusuke
    Nagahara, Kazunori
    Tanaka, Yoshihito
    Miyatake, Hiroki
    Hata, Hirofumi
    Hara, Toshimasa
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (05) : 695 - 700
  • [4] Combined early dynamic 18F-FDG PET/CT and conventional whole-body 18F-FDG PET/CT in hepatocellular carcinoma
    Yiqiu Zhang
    Yun Dong
    Wenjun Yu
    Shuguang Chen
    Haojun Yu
    Beilei Li
    Hongcheng Shi
    [J]. Abdominal Radiology, 2023, 48 : 3127 - 3134
  • [5] Combined early dynamic 18F-FDG PET/CT and conventional whole-body 18F-FDG PET/CT in hepatocellular carcinoma
    Zhang, Yiqiu
    Dong, Yun
    Yu, Wenjun
    Chen, Shuguang
    Yu, Haojun
    Li, Beilei
    Shi, Hongcheng
    [J]. ABDOMINAL RADIOLOGY, 2023, 48 (10) : 3127 - 3134
  • [6] Whole-body 18F-FDG PET in recurrent or metastatic nasopharyngeal carcinoma
    Yen, RF
    Hong, RL
    Tzen, KY
    Pan, MH
    Chen, THH
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (05) : 770 - 774
  • [7] Whole-body 18F-FDG PET/CT in Uveal Melanoma Patients
    Pursanova, D. M.
    Mukhortova, O. V.
    Aslanidis, I. P.
    Katunina, T. A.
    Saakyan, S. V.
    Avakyan, K. V.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S585 - S586
  • [8] Whole-body 18F-FDG PET/CT in the presence of truncation artifacts
    Beyer, T
    Bockisch, A
    Kühl, H
    Martinez, MJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (01) : 91 - 99
  • [9] Autoimmune pancreatitis: whole-body 18F-FDG PET/CT findings
    Jian Zhang
    Chengwei Shao
    Jianhua Wang
    Chao Cheng
    Changjing Zuo
    Gaofeng Sun
    Bin Cui
    Aisheng Dong
    Qinghua Liu
    Lingshan Kong
    [J]. Abdominal Imaging, 2013, 38 : 543 - 549
  • [10] Whole-Body 18F-FDG PET-CT in the Diagnosis of Neurosarcoidosis
    Fritz, Daan
    van de Beek, Diederik
    Brouwer, Matthijs C.
    Booij, Jan
    [J]. MAYO CLINIC PROCEEDINGS, 2020, 95 (05) : 1082 - 1084