Guidelines and considerations for the use of system suitability and quality control samples in mass spectrometry assays applied in untargeted clinical metabolomic studies

被引:0
|
作者
David Broadhurst
Royston Goodacre
Stacey N. Reinke
Julia Kuligowski
Ian D. Wilson
Matthew R. Lewis
Warwick B. Dunn
机构
[1] Edith Cowan University,School of Science, Centre for Integrative Metabolomics and Computational Biology
[2] Manchester Institute of Biotechnology,School of Chemistry
[3] University of Manchester,Separation Sciences and Metabolomics Laboratory
[4] Murdoch University,Neonatal Research Unit
[5] Health Research Institute La Fe,Division of Computational and Systems Medicine, Department of Surgery and Cancer
[6] Imperial College London,School of Biosciences
[7] University of Birmingham,Phenome Centre Birmingham
[8] University of Birmingham,Institute of Metabolism and Systems Research
[9] University of Birmingham,undefined
来源
Metabolomics | 2018年 / 14卷
关键词
Quality assurance (QA); Quality control (QC); System suitability samples; Pooled QC samples; Standard reference materials (SRMs); Long-term reference (LTR) QC samples;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 9 条
  • [1] Guidelines and considerations for the use of system suitability and quality control samples in mass spectrometry assays applied in untargeted clinical metabolomic studies
    Broadhurst, David
    Goodacre, Royston
    Reinke, Stacey N.
    Kuligowski, Julia
    Wilson, Ian D.
    Lewis, Matthew R.
    Dunn, Warwick B.
    METABOLOMICS, 2018, 14 (06)
  • [2] Standardization and quality control using control samples to minimize batch effects and improve reproducibility of mass cytometry (CyTOF) assays in human immunology studies
    Kleinsteuber, K.
    Corleis, B.
    Rashidi, N.
    Nchinda, N.
    Lisanti, A.
    Kwon, D.
    Walker, B.
    EUROPEAN JOURNAL OF IMMUNOLOGY, 2016, 46 : 1173 - 1173
  • [3] Mass Spectrometry and Multiplex Antigen Assays to Assess Microbial Quality and Toxin Production of Staphylococcus aureus Strains Isolated from Clinical and Food Samples
    Attien, Paul
    Sina, Haziz
    Moussaoui, Wardi
    Zimmermann-Meisse, Gaelle
    Dadie, Thomas
    Keller, Daniel
    Riegel, Philippe
    Edoh, Vincent
    Kotchoni, Simeon O.
    Dje, Marcellin
    Prevost, Gilles
    Baba-Moussa, Lamine
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [4] Normalization methods for reducing interbatch effect without quality control samples in liquid chromatography-mass spectrometry-based studies
    Alisa O. Tokareva
    Vitaliy V. Chagovets
    Alexey S. Kononikhin
    Natalia L. Starodubtseva
    Eugene N. Nikolaev
    Vladimir E. Frankevich
    Analytical and Bioanalytical Chemistry, 2021, 413 : 3479 - 3486
  • [5] Normalization methods for reducing interbatch effect without quality control samples in liquid chromatography-mass spectrometry-based studies
    Tokareva, Alisa O.
    Chagovets, Vitaliy V.
    Kononikhin, Alexey S.
    Starodubtseva, Natalia L.
    Nikolaev, Eugene N.
    Frankevich, Vladimir E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (13) : 3479 - 3486
  • [6] Use of synthetic urine as a matrix substitute for standard and quality control materials in the clinical assessment of iodine by inductively coupled plasma mass spectrometry
    Haglock-Adler, Carrie J.
    Hurley, Ayrea
    Strathmann, Frederick G.
    CLINICAL BIOCHEMISTRY, 2014, 47 (15) : 80 - 82
  • [7] Use of ultra-high-performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry system as valuable tool for an untargeted metabolomic profiling of Rumex tunetanus flowers and stems and contribution to the antioxidant activity
    Abidi, Jouda
    Ammar, Sonda
    Ben Brahim, Samia
    Skalicka-Wozniak, Krystyna
    Ghrabi-Gammar, Zeineb
    Bouaziz, Mohamed
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 : 66 - 81
  • [8] The use of a simple backflush technology to improve sample throughput and system robustness in routine gas chromatography tandem mass spectrometry analysis of doping control samples
    Gray, B. P.
    Teale, P.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (28) : 4749 - 4752
  • [9] The AutoPap 300 QC system multicenter clinical trials for use in quality control rescreening of cervical smears - II. Prospective and archival sensitivity studies
    Patten, SF
    Lee, JSJ
    Wilbur, DC
    Bonfiglio, TA
    Colgan, TJ
    Richart, RM
    Cramer, H
    Moinuddin, S
    CANCER CYTOPATHOLOGY, 1997, 81 (06): : 343 - 347