Quantitative X-ray phase-contrast microtomography from a compact laser-driven betatron source

被引:0
|
作者
J. Wenz
S. Schleede
K. Khrennikov
M. Bech
P. Thibault
M. Heigoldt
F. Pfeiffer
S. Karsch
机构
[1] Ludwig-Maximilians-Universität München,Abteilung für Attosekundenphysik
[2] Fakultät für Physik,Physik
[3] MPI für Quantenoptik,Department & Institut für Medizintechnik
[4] Lehrstuhl für Biomedizinische Physik,Department of Medical Radiation Physics
[5] Technische Universität München,Department of Physics and Astronomy
[6] Clinical Sciences,undefined
[7] Lund University,undefined
[8] University College London,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
X-ray phase-contrast imaging has recently led to a revolution in resolving power and tissue contrast in biomedical imaging, microscopy and materials science. The necessary high spatial coherence is currently provided by either large-scale synchrotron facilities with limited beamtime access or by microfocus X-ray tubes with rather limited flux. X-rays radiated by relativistic electrons driven by well-controlled high-power lasers offer a promising route to a proliferation of this powerful imaging technology. A laser-driven plasma wave accelerates and wiggles electrons, giving rise to a brilliant keV X-ray emission. This so-called betatron radiation is emitted in a collimated beam with excellent spatial coherence and remarkable spectral stability. Here we present a phase-contrast microtomogram of a biological sample using betatron X-rays. Comprehensive source characterization enables the reconstruction of absolute electron densities. Our results suggest that laser-based X-ray technology offers the potential for filling the large performance gap between synchrotron- and current X-ray tube-based sources.
引用
收藏
相关论文
共 50 条
  • [1] Quantitative X-ray phase-contrast microtomography from a compact laser-driven betatron source
    Wenz, J.
    Schleede, S.
    Khrennikov, K.
    Bech, M.
    Thibault, P.
    Heigoldt, M.
    Pfeiffer, F.
    Karsch, S.
    NATURE COMMUNICATIONS, 2015, 6
  • [2] X-ray phase-contrast tomography with a compact laser-driven synchrotron source
    Eggl, Elena
    Schleede, Simone
    Bech, Martin
    Achterhold, Klaus
    Loewen, Roderick
    Ruth, Ronald D.
    Pfeiffer, Franz
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2015, 112 (18) : 5567 - 5572
  • [3] Quick x-ray microtomography using a laser-driven betatron source
    Dopp, A.
    Hehn, L.
    Goetzfried, J.
    Wenz, J.
    Gilljohann, M.
    Ding, H.
    Schindler, S.
    Pfeiffer, F.
    Karsch, S.
    OPTICA, 2018, 5 (02): : 199 - 203
  • [4] The possibility of phase-contrast X-ray microtomography
    Momose, A
    Hirano, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 : 625 - 629
  • [5] X-ray phase-contrast microscopy and microtomography
    Mayo, SC
    Davis, TJ
    Gureyev, TE
    Miller, PR
    Paganin, D
    Pogany, A
    Stevenson, AW
    Wilkins, SW
    OPTICS EXPRESS, 2003, 11 (19): : 2289 - 2302
  • [6] Design of X-ray interferometer for phase-contrast X-ray microtomography
    Momose, A
    Hirano, K
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 98 - 103
  • [7] Quantitative characterization and diagnosis via hard X-ray phase-contrast microtomography
    Liu, Huiqiang
    Ji, Xuewen
    Ma, Yan
    Du, Guohao
    Fu, Yanan
    Abudureheman, Yibanu
    Liu, Wenya
    MICROSCOPY RESEARCH AND TECHNIQUE, 2018, 81 (10) : 1173 - 1181
  • [8] Compact laser accelerators for X-ray phase-contrast imaging
    Najmudin, Z.
    Kneip, S.
    Bloom, M. S.
    Mangles, S. P. D.
    Chekhlov, O.
    Dangor, A. E.
    Doepp, A.
    Ertel, K.
    Hawkes, S. J.
    Holloway, J.
    Hooker, C. J.
    Jiang, J.
    Lopes, N. C.
    Nakamura, H.
    Norreys, P. A.
    Rajeev, P. P.
    Russo, C.
    Streeter, M. J. V.
    Symes, D. R.
    Wing, M.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 372 (2010):
  • [9] Phase-contrast X-ray microtomography of mouse fetus
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    BIOLOGY OPEN, 2012, 1 (03): : 269 - 274
  • [10] High-resolution μCT of a mouse embryo using a compact laser-driven X-ray betatron source
    Cole, Jason M.
    Symes, Daniel R.
    Lopes, Nelson C.
    Wood, Jonathan C.
    Poder, Kristjan
    Alatabi, Saleh
    Botchway, Stanley W.
    Foster, Peta S.
    Gratton, Sarah
    Johnson, Sara
    Kamperidis, Christos
    Kononenko, Olena
    De lazzari, Michael
    Palmer, Charlotte A. J.
    Rusby, Dean
    Sanderson, Jeremy
    Sandholzer, Michael
    Sarri, Gianluca
    Szoke-Kovacs, Zsombor
    Teboul, Lydia
    Thompson, James M.
    Warwick, Jonathan R.
    Westerberg, Henrik
    Hill, Mark A.
    Norris, Dominic P.
    Mangles, Stuart P. D.
    Najmudin, Zulfikar
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2018, 115 (25) : 6335 - 6340