Precision of computer-assisted core decompression drilling of the femoral head

被引:0
|
作者
J. Beckmann
J. Goetz
H. Baethis
T. Kalteis
J. Grifka
L. Perlick
机构
[1] Orthopaedic Clinic of the University of Regensburg,
[2] Asklepios Klinik Bad Abbach,undefined
关键词
Osteonecrosis dissecans; Core decompression; Precision; Navigation; Computer-aided surgery;
D O I
暂无
中图分类号
学科分类号
摘要
Introduction: Osteonecrosis of the femoral head is a local destructive disease with progression into devastating stages. Left untreated it mostly leads to severe secondary osteoarthrosis and early endoprosthetic joint replacement. Core decompression by exact drilling into the ischemic areas can be performed in early stages according to Ficat or ARCO. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision® navigation system in an in vitro model. Materials and methods: Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. Twenty sawbones were drilled by guidance of an intraoperative navigation system VectorVision® (BrainLAB, Munich, Germany) and 10 sawbones by fluoroscopic control only. Results: No gypsum sphere was missed. There was a statistically significant difference regarding the three-dimensional deviation (Euclidian norm) as well as maximum deviation in x-, y- or z-direction (maximum norm) to the desired mid-point of the lesion, with a mean of 0.51 and 0.4 mm in the navigated group and 1.1 and 0.88 mm in the control group, respectively. Furthermore, significant difference was found in the number of drilling corrections as well as the radiation time needed: no second drilling or correction of drilling direction was necessary in the navigated group compared to 1.4 in the control group. The radiation time needed was less than 1 s compared to 3.1 s, respectively. Conclusion: The fluoroscopy-based VectorVision® navigation system shows a high feasibility of computer-guided drilling with a clear reduction of radiation exposure time and can therefore be integrated into clinical routine. The additional time needed is acceptable regarding the simultaneous reduction of radiation time.
引用
收藏
页码:374 / 379
页数:5
相关论文
共 50 条
  • [1] Precision of computer-assisted core decompression drilling of the femoral head
    Beckmann, J.
    Goetz, J.
    Baethis, H.
    Kalteis, T.
    Grifka, J.
    Perlick, L.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (06) : 374 - 379
  • [2] Precision of computer-assisted core decompression drilling of the knee
    Beckmann, J
    Goetz, J
    Bäthis, H
    Kalteis, T
    Grifka, J
    Perfick, L
    KNEE, 2006, 13 (03): : 211 - 215
  • [3] Core decompression and alendronate treatment of the osteonecrotic rat femoral head: computer-assisted analysis
    Peled, Eli
    Bejar, Jacob
    Barak, Michal
    Orion, Eyal
    Norman, Doron
    INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, 2013, 94 (03) : 212 - 216
  • [4] Endoscopically assisted core decompression in avascular necrosis of the femoral head
    Govaers, Kris
    Meermans, Geert
    Bortier, Hilde
    Londers, Jurgen
    ACTA ORTHOPAEDICA BELGICA, 2009, 75 (05): : 631 - 636
  • [5] Arthroscopic-Assisted Core Decompression for Osteonecrosis of the Femoral Head
    Gupta, Anil K.
    Frank, Rachel M.
    Harris, Joshua D.
    McCormick, Frank
    Mather, Richard C.
    Nho, Shane J.
    ARTHROSCOPY TECHNIQUES, 2014, 3 (01): : E7 - E11
  • [6] Accuracy and Safety of Robot-Assisted Drilling Decompression for Osteonecrosis of the Femoral Head
    Luo, Jin
    Yan, Ya-jing
    Wang, Xiao-dong
    Long, Xu-dong
    Lan, Hai
    Li, Kai-nan
    ORTHOPAEDIC SURGERY, 2020, 12 (03) : 784 - 791
  • [7] Core decompression for osteonecrosis of the femoral head
    Markel, DC
    Miskovsky, C
    Sculco, TP
    Pellicci, PM
    Salvati, EA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (323) : 226 - 233
  • [8] Computer-assisted image analysis of the rat postosteonecrotic remodeled femoral head
    Sabo, E
    Peskin, B
    Misselevich, I
    Zinman, C
    Levin, D
    Norman, D
    Reis, DN
    Boss, JH
    EXPERIMENTAL AND MOLECULAR PATHOLOGY, 2001, 71 (03) : 256 - 264
  • [9] Core decompression of the femoral head for avascular necrosis
    Bellot, F
    Havet, E
    Gabrion, A
    Meunier, W
    Mertl, P
    de Lestang, M
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (02): : 114 - 123
  • [10] Bilateral core decompression for osteonecrosis of the femoral head
    Israelite, C
    Nelson, CL
    Ziarani, CF
    Abboud, JA
    Landa, J
    Steinberg, ME
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 285 - 290