Measurements of formaldehyde and TVOC emission from paints and coating materials using small chamber method for building composites

被引:0
|
作者
Jin-A. Kim
Sumin Kim
Hyun-Joong Kim
Janghoo Seo
机构
[1] Seoul National University,National Instrumentation Center for Environmental Management
[2] Seoul National University,Laboratory of Adhesion & Bio
[3] Soongsil University,Composites, Program in Environmental Materials Science
[4] Chosun University,Building Environment & Materials Lab, School of Architecture
关键词
formaldehyde; TVOC; paints; coating materials; FLEC;
D O I
暂无
中图分类号
学科分类号
摘要
An optimal test method for paint is proposed; additionally, the Field and Laboratory Emission Cell (FLEC) method used in Europe is applied as a substitute for the 20 L small chamber method. The emission factors of total volatile organic compounds (TVOC) and formaldehyde from oil-based paint, emulsion paint, and water-dispersion paint with a coating weight of 300 g/m2, cured for 24/48 hours, were measured using the 20 L small chamber method. The emission rate of TVOC and formaldehyde from all paints began to stabilize after approximately 7 days after 24/48 hours of curing even though Korean standards stipulate that paint should be measured and analyzed after the third day of application. The emission factor of TVOC and formaldehyde from oil-based, emulsion, and water-dispersion paints were also measured using the FLEC method. There was good correlation between the 20 L small chamber method and the FLEC method for oil-based, emulsion, and water-dispersion paint emissions. With the FLEC method, using paints prepared under identical conditions, the emission rate was stable 24 hours after installation of samples because the air flow rate of FLEC is much higher than that of a 20 L small chamber, and the relative cell volume of FLEC is much smaller than that of a 20 L small chamber.
引用
收藏
页码:120 / 125
页数:5
相关论文
共 50 条
  • [1] Measurements of Formaldehyde and TVOC Emission from Paints and Coating Materials using Small Chamber Method for Building Composites
    Jin-A KIM
    Sumin KIM
    Hyun-Joong KIM
    Janghoo SEO
    Journal of Wuhan University of Technology(Materials Science), 2012, (01) : 120 - 125
  • [2] Measurements of Formaldehyde and TVOC Emission from Paints and Coating Materials using Small Chamber Method for Building Composites
    Kim, Jin-A
    Kim, Sumin
    Kim, Hyun-Joong
    Seo, Janghoo
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2012, 27 (01): : 120 - 125
  • [3] Measurements of Formaldehyde and TVOC Emission from Paints and Coating Materials using Small Chamber Method for Building Composites
    JinA KIM
    Sumin KIM
    HyunJoong KIM
    Janghoo SEO
    Journal of Wuhan University of Technology(Materials Science Edition), 2012, 27 (01) : 120 - 125
  • [4] Determination of formaldehyde and TVOC emission factor from wood-based composites by small chamber method
    Kim, Sumin
    Kim, Jin-A
    Kim, Hyun-Joong
    Kim, Shin Do
    POLYMER TESTING, 2006, 25 (05) : 605 - 614
  • [5] Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method
    Lee, Suk-Jo
    Jang, Seong-Ki
    Cho, Yong-Sung
    Jung, Kyung-Mi
    Jeongt, Gi-Ho
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2005, 21 (02) : 191 - 204
  • [6] Evaluation of formaldehyde and VOCs emission factors from paints in a small chamber: The effects of preconditioning time and coating weight
    Kim, Jin-A
    Kim, Sumin
    Kim, Hyun-Joong
    Kim, Yong-Shik
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 187 (1-3) : 52 - 57
  • [7] Formaldehyde and TVOC emission behaviors according to finishing treatment with surface materials using 20 L chamber and FLEC
    Kim, Ki-Wook
    Kim, Sumin
    Kim, Hyun-Joong
    Park, Jin Chul
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 177 (1-3) : 90 - 94
  • [8] MEASUREMENTS OF FORMALDEHYDE RELEASE FROM BUILDING-MATERIALS IN A VENTILATED TEST CHAMBER
    GUSTAFSSON, HNO
    ACS SYMPOSIUM SERIES, 1986, 316 : 145 - 153
  • [9] Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber
    Lee, Suk-Jo
    Jang, Seong-Ki
    Kim, Mi-Hyun
    Lee, Hong-Suk
    Lim, Jun-ho
    Jang, Mee
    Seo, Soo-yun
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2005, 18 (04): : 344 - 354
  • [10] Exponential Decay Model of TVOC Emission from Indoor Building Materials
    Zhang, Y.
    Niu, Y. R.
    Liu, Y.
    Wu, Y. F.
    Jiang, J. X.
    Guan, H. Y.
    Guo, Z. B.
    4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ENGINEERING AND SUSTAINABLE DEVELOPMENT (CEESD 2019), 2020, 435