Surface cleaning techniques: ultra-trace ICP-MS sample preparation and assay of HDPE

被引:0
|
作者
N. R. Overman
E. W. Hoppe
R. S. Addleman
机构
[1] Pacific Northwest National Laboratory,
关键词
HDPE; Leaching; Ultra-trace; ICP-MS; Uranium; Thorium;
D O I
暂无
中图分类号
学科分类号
摘要
The world’s most sensitive radiation detection and assay systems depend upon ultra-low-background (ULB) materials to reduce unwanted radiological backgrounds. In this study, we evaluate methods to clean HDPE, a material of interest to ULB systems and the means to provide rapid assay of surface and bulk contamination. ULB-level material and ultra-trace-level detection of actinide elements is difficult to attain, due to the introduction of contamination from sample preparation equipment such as pipette tips, sample vials, forceps, etc and airborne particulate. To date, literature available on the cleaning of such polymeric materials and equipment for ULB applications and ultra-trace analyses is limited. For these reasons, a study has been performed to identify an effective way to remove surface contamination from polymers in an effort to provide improved instrumental detection limits. Inductively Coupled Plasma Mass Spectroscopy was utilized to assess the effectiveness of a variety of leachate solutions for removal of inorganic uranium and thorium surface contamination from polymers, specifically high density polyethylene (HDPE). Leaching procedures for HDPE were tested to optimize contaminant removal of thorium and uranium. Calibration curves for thorium and uranium ranged from 15 ppq (fg/mL) to 1 ppt (pg/mL). Detection limits were calculated at 6 ppq for uranium and 7 ppq for thorium. Results showed the most effective leaching reagent to be clean 6 M nitric acid for 72 h exposures. Contamination levels for uranium and thorium found in the leachate solutions were significant for ultra-low-level radiation detection applications.
引用
收藏
页码:1303 / 1310
页数:7
相关论文
共 50 条
  • [1] Surface cleaning techniques: ultra-trace ICP-MS sample preparation and assay of HDPE
    Overman, N. R.
    Hoppe, E. W.
    Addleman, R. S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (03) : 1303 - 1310
  • [2] Determination of Ultra-trace Hg in Geothermal Water Using ICP-MS/MS
    Yan, Dong
    Guo, Wei
    Guo, Qinghai
    Jin, Lanlan
    Hu, Shenghong
    ATOMIC SPECTROSCOPY, 2024, 45 (06)
  • [4] Determination of 210Pb at ultra-trace levels in water by ICP-MS
    Larivière, D
    Reiber, KM
    Evans, RD
    Cornett, RJ
    ANALYTICA CHIMICA ACTA, 2005, 549 (1-2) : 188 - 196
  • [5] NAA AND ICP-MS - A COMPARISON BETWEEN 2 METHODS FOR TRACE AND ULTRA-TRACE ELEMENT ANALYSIS
    MOENS, L
    DAMS, R
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 192 (01): : 29 - 38
  • [6] Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS
    Balcaen, Lieve
    Bolea-Fernandez, Eduardo
    Resano, Martin
    Vanhaecke, Frank
    ANALYTICA CHIMICA ACTA, 2014, 809 : 1 - 8
  • [7] Advances in ICP-MS technologies for characterization and ultra-trace speciation as a tool for the petroleum industry
    Paszek, J
    Mason, KJ
    Mennito, AS
    McElroy, FC
    Elemental Analysis of Fuels and Lubricants: Recent Advances and Future Prospects, 2005, 1468 : 42 - 50
  • [8] An efficient method for the removal of Pb prior to the ultra-trace Am measurement by ICP-MS
    Wang, Yufeng
    Fan, Jinlong
    Zhai, Xiufang
    Li, Zhiming
    Yu, Qingjiang
    Zhang, Weichao
    Liu, Zhichao
    RADIOCHIMICA ACTA, 2022, 110 (10) : 825 - 831
  • [9] Automated separation of ultra-trace actinides from urine by ion chromatography ICP-MS
    Jones, Robert L.
    Caldwell, Kathleen L.
    Gonzales, Edward R.
    Peterson, Dominic S.
    Walter, Peter J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [10] Geographic origin of wine via trace and ultra-trace elemental analysis using ICP-MS and chemometrics
    Jaganathan, J
    Mabud, MA
    Dugar, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U40 - U40