Comparison of the Micronaut Merlin automated broth microtiter system with the standard agar dilution method for antimicrobial susceptibility testing of mucoid and nonmucoid Pseudomonas aeruginosa isolates from cystic fibrosis patients

被引:0
|
作者
B. Balke
L. Hoy
H. Weissbrodt
S. Häussler
机构
[1] Medizinische Hochschule Hannover,Institut für Medizinische Mikrobiologie und Krankenhaushygiene
[2] Medizinische Hochschule Hannover,Institut für Biometrie
[3] Abteilung Zellbiologie,Gesellschaft für Biotechnologische Forschung
关键词
Cystic Fibrosis; Susceptibility Testing; Meropenem; Cystic Fibrosis Patient; Major Error;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to compare a commercially available automated broth microdilution system (Merlin; Micronaut, Germany) with the standard agar dilution method for susceptibility testing of pulmonary isolates from cystic fibrosis patients. Accurate susceptibility testing of bacterial isolates from cystic fibrosis patients is known to pose problems. Although commercially available automated test systems could facilitate susceptibility testing of such isolates in routine diagnostics, these systems have not been recommended thus far. However, a pilot study recently indicated that the Merlin system, which is based on an endpoint measurement rather than on growth curves, might be applicable in the susceptibility testing of isolates from cystic fibrosis patients. In the present study, the Merlin system was further evaluated using an extended panel of nonmucoid and mucoid Pseudomonas aeruginosa isolates. The results showed that the MICs obtained with the Merlin system tended to be lower than those obtained with the agar dilution method, a finding that became increasingly apparent when mucoid Pseudomonas aeruginosa strains were tested. The correlation coefficients (r values) of the MIC results for all strains tested were between 0.6 and 0.8 for five of the seven antimicrobial agents, with r values exceeding 0.8 for only meropenem and ciprofloxacin. However, since the overall rate of serious discrepancies was within an acceptable range, the Merlin system appears to be applicable for routine clinical use in susceptibility testing of P. aeruginosa isolates from cystic fibrosis patients.
引用
收藏
页码:765 / 771
页数:6
相关论文
共 25 条
  • [1] Comparison of the Micronaut Merlin automated broth microtiter system with the standard agar dilution method for antimicrobial susceptibility testing of mucoid and nonmucoid Pseudomonas aeruginosa isolates from cystic fibrosis patients
    Balke, B
    Hoy, L
    Weissbrodt, H
    Häussler, S
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2004, 23 (10) : 765 - 771
  • [2] Comparison of standard agar dilution with the Merlin, Micronaut System for automated broth microtiter antimicrobial susceptibility testing of mucoid and non-mucoid Pseudomonas aeruginosa isolates from cystic fibrosis patients
    Balke, B
    Hoy, L
    Weissbrodt, H
    Haeussler, S
    [J]. INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2004, 294 : 147 - 147
  • [3] Evaluation of the Merlin, Micronaut System for Automated Antimicrobial Susceptibility Testing of Pseudomonas aeruginosa and Burkholderia Species Isolated from Cystic Fibrosis Patients
    S. Häussler
    S. Ziesing
    G. Rademacher
    L. Hoy
    H. Weißbrodt
    [J]. European Journal of Clinical Microbiology and Infectious Diseases , 2003, 22 : 496 - 500
  • [4] Evaluation of the Merlin, Micronaut system for automated antimicrobial susceptibility testing of Pseudomonas aeruginosa and Burkholderia species isolated from cystic fibrosis patients
    Häussler, S
    Ziesing, S
    Rademacher, G
    Hoy, L
    Weissbrodt, H
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2003, 22 (08) : 496 - 500
  • [5] Comparison of agar diffusion methodologies for antimicrobial susceptibility testing of Pseudomonas aeruginosa isolates from cystic fibrosis patients
    Burns, JL
    Saiman, L
    Whittier, S
    Larone, D
    Krzewinski, J
    Liu, Z
    Marshall, SA
    JOnes, RN
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) : 1818 - 1822
  • [6] Comparison of agardilution and broth microdilution for the susceptibility testing of Pseudomonas aeruginosa isolates from Cystic Fibrosis patients
    Hogardt, M
    Schmoldt, S
    Götzfried, M
    Heesemann, J
    [J]. INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2004, 294 : 232 - 233
  • [7] Heterogeneous Antimicrobial Susceptibility Characteristics in Pseudomonas aeruginosa Isolates from Cystic Fibrosis Patients
    Qin, Xuan
    Zhou, Chuan
    Zerr, Danielle M.
    Adler, Amanda
    Addetia, Amin
    Yuan, Shuhua
    Greninger, Alexander L.
    [J]. MSPHERE, 2018, 3 (02)
  • [8] Antimicrobial susceptibility testing of cystic fibrosis and non-cystic fibrosis clinical isolates of Pseudomonas aeruginosa: a comparison of three methods
    Bradbury, R. S.
    Tristram, S. G.
    Roddam, L. F.
    Reid, D. W.
    Inglis, T. J. J.
    Champion, A. C.
    [J]. BRITISH JOURNAL OF BIOMEDICAL SCIENCE, 2011, 68 (01) : 1 - 4
  • [9] PSEUDOMONAS-AERUGINOSA FROM CYSTIC-FIBROSIS PATIENTS - SUSCEPTIBILITY TESTING OF ORAL ISOLATES
    KAUFMAN, AK
    LINDEMANN, RA
    NEWMAN, MG
    LE, TV
    [J]. JOURNAL OF DENTAL RESEARCH, 1984, 63 : 186 - 186
  • [10] Evaluation of reference dilution test methods for antimicrobial susceptibility testing of Pseudomonas aeruginosa strains isolated from patients with cystic fibrosis
    Saiman, L
    Burns, JL
    Whittier, S
    Krzewinski, J
    Marshall, SA
    Jones, RN
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (09) : 2987 - 2991