Novel Potentiometric Membrane Sensor for the Determination of Trace Amounts of Chromium(III) Ions

被引:0
|
作者
Mohammad Reza Ganjali
Farhang Mizani
Masoud Salavati-Niasari
Mehran Javanbakht
机构
[1] Tehran University,Department of Chemistry, Faculty of Science
[2] Kashan University,Department of Chemistry, Faculty of Science
[3] Tarbiat Modarres University,Department of Chemistry, Faculty of Science
关键词
D O I
10.2116/analsci.19.235
中图分类号
学科分类号
摘要
A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0 × 10-6 - 1.0 × 10-1 M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline earth, transition and heavy metal ions, and minimal interference are caused by Li+, Na+, K+, Co2+, Hg2+, Ca2+, Pb2+ and Zn2+ ions, which are known to interfere with other chromium membrane sensors. The TTCT-based electrode shows a fast response time (15 s), and can be used in aqueous solutions of pH 3 - 5.5. The proposed sensor was used for the potentiometric titration of Cr3+ with EDTA and for a direct potentiometric determination of Cr3+ content in environmental samples.
引用
收藏
页码:235 / 238
页数:3
相关论文
共 50 条
  • [1] Novel potentiometric membrane sensor for the determination of trace amounts of chromium(III) ions
    Ganjali, MR
    Mizani, F
    Salavati-Niasari, M
    Javanbakht, M
    ANALYTICAL SCIENCES, 2003, 19 (02) : 235 - 238
  • [2] Novel potentiometric membrane sensor for selective determination of aluminum(III) ions
    Saleh, MB
    Hassan, SSM
    Gaber, AAA
    Kream, NAA
    ANALYTICA CHIMICA ACTA, 2001, 434 (02) : 247 - 253
  • [3] Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions
    Hassan, SSM
    Abbas, MN
    Moustafa, GAE
    TALANTA, 1996, 43 (05) : 797 - 804
  • [4] A novel tetrachlorothallate (III)-PVC membrane sensor for the potentiometric determination of thallium (III)
    Hassanien, MM
    Abou-El-Sherbini, KS
    Mostafa, GAE
    TALANTA, 2003, 59 (02) : 383 - 392
  • [5] Novel Membrane Potentiometric Sulfate Ion Sensor Based on Zinc-Phthalocyanine for the Quick Determination of Trace Amounts of Sulfate
    Mohammad Reza Ganjali
    Mohammad Reza Pourjavid
    Mojtaba Shamsipur
    Taherh Poursaeri
    Morteza Rezapour
    Mehran Javanbakht
    Hashem Sharghi
    Analytical Sciences, 2003, 19 : 995 - 999
  • [6] Novel membrane potentiometric sulfate ion sensor based on zinc-phthalocyanine for the quick determination of trace amounts of sulfate
    Ganjali, MR
    Poujavid, MR
    Shamsipur, M
    Poursaeri, T
    Rezapour, M
    Javanbakht, M
    Sharghi, H
    ANALYTICAL SCIENCES, 2003, 19 (07) : 995 - 999
  • [7] DETERMINATION OF TRACE AMOUNTS OF CHROMIUM(III) USING CHEMILUMINESCENCE ANALYSIS
    SEITZ, WR
    SUYDAM, WW
    HERCULES, DM
    ANALYTICAL CHEMISTRY, 1972, 44 (06) : 957 - &
  • [8] The solid potentiometric electrode for determination of chromium (III, VI) ions
    Amerkhanova, Sh. K.
    BULLETIN OF THE UNIVERSITY OF KARAGANDA-CHEMISTRY, 2013, (69): : 29 - 33
  • [9] A Potentiometric Rhodamine-B Based Membrane Sensor for the Selective Determination of Chromium Ions in Wastewater
    Saad S. M. Hassan
    M. S. El-Shahawi
    A. M. Othman
    M. A. Mosaad
    Analytical Sciences, 2005, 21 : 673 - 678
  • [10] A potentiometric rhodamine-B based membrane sensor for the selective determination of chromium ions in wastewater
    Hassan, SSM
    El-Shahawi, MS
    Othman, AM
    Mosaad, MA
    ANALYTICAL SCIENCES, 2005, 21 (06) : 673 - 678