Comparison of parametric FBP and OS-EM reconstruction algorithm images for PET dynamic study

被引:0
|
作者
Keiichi Oda
Hinako Toyama
Koji Uemura
Yoko Ikoma
Yuichi Kimura
Michio Senda
机构
[1] National Institute of Radiological Sciences,Research Center for Charged Particle Therapy
[2] Waseda University,School of Science and Engineering
[3] Tokyo Metropolitan Institute of Gerontology,Positron Medical Center
来源
关键词
parametric image; filtered backprojection; ordered subsets expectation maximization; PET;
D O I
暂无
中图分类号
学科分类号
摘要
An ordered subsets expectation maximization (OS-EM) algorithm is used for image reconstruction to suppress image noise and to make non-negative value images. We have applied OS-EM to a digital brain phantom and to human brain18F-FDG PET kinetic studies to generate parametric images. A 45 min dynamic scan was performed starting injection of FDG with a 2 D PET scanner. The images were reconstructed with OS-EM (6 iterations, 16 subsets) and with filtered backprojection (FBP), and K1, k2 and k3 images were created by the Marquardt non-linear least squares method based on the 3-parameter kinetic model. Although the OS-EM activity images correlated fairly well with those obtained by FBP, the pixel correlations were poor for the k2 and k3 parametric images, but the plots were scattered along the line of identity and the mean values for K1, k2 and k3 obtained by OS-EM were almost equal to those by FBP. The kinetic fitting error for OS-EM was no smaller than that for FBP. The results suggest that OS-EM is not necessarily superior to FBP for creating parametric images.
引用
收藏
页码:417 / 423
页数:6
相关论文
共 50 条
  • [1] Comparison of parametric FBP and OS-EM reconstruction algorithm images for PET dynamic study
    Oda, K
    Toyama, H
    Uemura, K
    Ikoma, Y
    Kimura, Y
    Senda, M
    [J]. ANNALS OF NUCLEAR MEDICINE, 2001, 15 (05) : 417 - 423
  • [2] Effect of reconstruction algorithm on parametric images in PET dynamic study: Comparison between FBP and OS-EM
    Oda, K
    Toyama, H
    Uemura, K
    Ikoma, Y
    Kimura, Y
    Senda, M
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1542 - 1545
  • [3] Signal to noise ratio in neurologic FDG PET: Comparison of FBP and OS-EM reconstruction algorithms.
    Fulton, RR
    Meikle, SR
    Eberl, S
    Hooper, PK
    Fulham, MJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 998 - 998
  • [4] Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera:: a phantom and a clinical 18F-FDG study
    Gutman, F
    Gardin, I
    Delahaye, N
    Rakotonirina, H
    Hitzel, A
    Manrique, A
    Le Guludec, D
    Véra, P
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (11) : 1510 - 1519
  • [5] Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study
    Fabrice Gutman
    Isabelle Gardin
    Nicolas Delahaye
    Hervé Rakotonirina
    Anne Hitzel
    Alain Manrique
    Dominique Le Guludec
    Pierre Véra
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 1510 - 1519
  • [6] OS-EM reconstruction vs. filtered back projection (FBP) reconstruction for neurologic FDG PET studies: Improved image quality?
    Fulton, RR
    Meikle, SR
    Hooper, PK
    Eberl, S
    Silver, KM
    Fulham, MJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 872 - 872
  • [7] A provably convergent OS-EM like reconstruction algorithm for emission tomography
    Hsiao, IT
    Rangarajan, A
    Gindi, G
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 10 - 19
  • [8] OS-EM reconstruction for X-ray CT
    Dong Baoyu
    [J]. ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL IV, 2007, : 565 - 568
  • [9] Application of the OS-EM method to the restoration of LBT images
    Bertero, M
    Boccacci, P
    [J]. ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 2000, 144 (01): : 181 - 186
  • [10] Comparison of Q.Clear (regularized) reconstruction versus OS-EM for characterization of small lesions in oncologic PET/CT
    Howard, Brandon
    James, Olga
    Borges-Neto, Salvador
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57