Design and performance evaluation of a novel robotic catheter system for vascular interventional surgery

被引:0
|
作者
Jian Guo
Shuxiang Guo
Lin Shao
Peng Wang
Qiang Gao
机构
[1] Tianjin University of Technology,Tianjin Key Laboratory for Control Theory and Application in Complicated Systems and Biomedical Robot Laboratory
[2] Kagawa University,Intelligent Mechanical Systems Engineering Department
来源
Microsystem Technologies | 2016年 / 22卷
关键词
Force Feedback; Master Manipulator; Master Controller; Slave Side; Master Side;
D O I
暂无
中图分类号
学科分类号
摘要
Vascular interventional surgery (VIS) is an effective treatment method for vascular diseases. However, there are many problems in traditional VIS, such as surgeons are radiated by X-ray, the lack of well skilled surgeons, the security of the surgery will be reduced due to the Surgeons’ fatigue, high risk of the surgery. To solve these problems, a robotic catheter system is needed to protect the surgeons and enhance the safety of the surgery. In this paper, a novel robotic catheter system with master–slave structure for VIS has been developed. This system is designed with the consideration of the operation method in traditional VIS, which allows the surgeon to operate a real catheter on the master side, then the surgeon make full use of the natural catheter manipulation experience and skills obtained in conventional catheter operation. The salve manipulator operates the catheter insert into the blood vessel with following the operation of the surgeon, and the operating force of the salve manipulator is detected. On the master side, a novel damper-based magnetorheological (MR) fluid is designed to realize the force feedback, which is also used to reappear the operation force from the salve manipulator. The damper connected directly with real catheter is a piston structure using the MR fluid to realize the force feedback. It can transmit the feedback force to surgeon’s hand through the operating catheter connected with damper, which seems that the surgeon operates the catheter beside the patient. The operating transparency of the developed system has been enhanced. The mechanism of the developed system has been introduced in detail. Performance evaluation experiments for the developed robotic catheter system have been done. The experimental results indicated that the developed robotic catheter system is fit for VIS.
引用
收藏
页码:2167 / 2176
页数:9
相关论文
共 50 条
  • [1] Design and performance evaluation of a novel robotic catheter system for vascular interventional surgery
    Guo, Jian
    Guo, Shuxiang
    Shao, Lin
    Wang, Peng
    Gao, Qiang
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2016, 22 (09): : 2167 - 2176
  • [2] A Novel Master-slave Robotic Catheter System for Vascular Interventional Surgery
    Guo, Shuxiang
    Wang, Peng
    Guo, Jian
    Wei, Wei
    Ji, Yuehui
    Wang, Yunliang
    [J]. 2013 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2013, : 951 - 956
  • [3] Design and performance evaluation of a novel vascular interventional surgery robot
    Li, Long
    Huang, Zhihui
    Tian, Yingzhong
    Wang, Wenbing
    Chen, Wei
    Li, Zexi
    Xi, Fengfeng
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2018, : 176 - 181
  • [4] Design and Evaluation of a Novel Slave Manipulator for the Vascular Interventional Robotic System
    Guo, Jian
    Meng, Cheng
    Guo, Shuxiang
    Fu, Qiang
    Zhan, Qi
    Qi, Lei
    [J]. 2019 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2019, : 1350 - 1355
  • [5] Design and characteristics evaluation of a novel teleoperated robotic catheterization system with force feedback for vascular interventional surgery
    Jian Guo
    Shuxiang Guo
    Yang Yu
    [J]. Biomedical Microdevices, 2016, 18
  • [6] Design and characteristics evaluation of a novel teleoperated robotic catheterization system with force feedback for vascular interventional surgery
    Guo, Jian
    Guo, Shuxiang
    Yu, Yang
    [J]. BIOMEDICAL MICRODEVICES, 2016, 18 (05)
  • [7] Evaluation of a Clamping Mechanism for Vascular Interventional Surgery Robotic System
    Shi, Chaochao
    Guo, Shuxiang
    [J]. 2021 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2021), 2021, : 1044 - 1049
  • [8] Internet-based Robotic Catheter Surgery System -System Design and Performance Evaluation
    Xiao, Nan
    Guo, Shuxiang
    Gao, Baofeng
    Ma, Xu
    Tamiya, Takashi
    Kawanishi, Masahiko
    [J]. 2012 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND LOGISTICS (ICAL), 2012, : 634 - 640
  • [9] A Novel Sensing System of Catheter/Guidewire Operation for Vascular Interventional Surgery
    Zhao, Yan
    Guo, Shuxiang
    Xiao, Nan
    Wang, Yuxin
    Zhang, Chaonan
    Bao, Xianqiang
    Wu, Jiaqing
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2017, : 416 - 421
  • [10] Performance Evaluation of a Vascular Interventional Surgery Robotic System with Visual-Based Force Feedback
    Shi, Chaochao
    Ishihara, Hidenori
    [J]. MACHINES, 2023, 11 (07)