Handwashing sinks and their associated premise plumbing are an ideal environment for pathogen-harboring biofilms to grow and spread throughout facilities due to the connected system of wastewater plumbing. This study was designed to understand the distribution of pathogens and antibiotic resistant organisms (ARO) within and among handwashing sinks in healthcare settings, using culture-dependent methods to quantify Pseudomonas aeruginosa, opportunistic pathogens capable of growth on a cefotaxime-containing medium (OPP-C), and carbapenem-resistant Enterobacteriaceae (CRE). Isolates from each medium identified as P. aeruginosa or Enterobacteriaceae were tested for susceptibility to aztreonam, ceftazidime, and meropenem; Enterobacteriaceae were also tested against ertapenem and cefotaxime. Isolates exhibiting resistance or intermediate resistance were designated ARO. Pathogens were quantified at different locations within handwashing sinks and compared in quantity and distribution between healthcare personnel (HCP) and patient room (PR) sinks. ARO were compared between samples within a sink (biofilm vs planktonic samples) and between sink types (HCP vs. PR). The drain cover was identified as a reservoir within multiple sinks that was often colonized by pathogens despite daily sink cleaning. P. aeruginosa and OPP-C mean log10 CFU/cm2 counts were higher in p-trap and tail pipe biofilm samples from HCP compared to PR sinks (2.77  ± 2.39 vs. 1.23 ± 1.62 and 5.27 ± 1.10 vs. 4.74 ± 1.06) for P. aeruginosa and OPP-C, respectively. P. aeruginosa and OPP-C mean log10 CFU/ml counts were also higher (p < 0.05) in HCP compared to PR sinks p-trap water (2.21 ± 1.52 vs. 0.89 ± 1.44 and 3.87 ± 0.78 vs. 3.21 ± 1.11) for P. aeruginosa and OPP-C, respectively. However, a greater percentage of ARO were recovered from PR sinks compared to HCP sinks (p < 0.05) for Enterobacteriaceae (76.4 vs. 32.9%) and P. aeruginosa (25.6 vs. 0.3%). This study supports previous work citing that handwashing sinks are reservoirs for pathogens and ARO and identifies differences in pathogen and ARO quantities between HCP and PR sinks, despite the interconnected premise plumbing.
引用
收藏
相关论文
共 4 条
  • [1] A microbiological survey of handwashing sinks in the hospital built environment reveals differences in patient room and healthcare personnel sinks
    Franco, Lauren C.
    Tanner, Windy
    Ganim, Christine
    Davy, Terri
    Edwards, Jonathan
    Donlan, Rodney
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] A microbiological survey approach to understanding the virulence factors of Pseudomonas species in healthcare sinks
    Rickard, H.
    Cloutman-Green, E.
    Ciric, L.
    JOURNAL OF HOSPITAL INFECTION, 2024, 151
  • [3] Room of Hazards: A Comparison of Differences in Safety Hazard Recognition Among Various Hospital-Based Healthcare Professionals and Trainees in a Simulated Patient Room
    Wang, Melinda
    Banda, Barbara
    Rodwin, Benjamin A.
    Merchant, Naseema B.
    JOURNAL OF PATIENT SAFETY, 2022, 18 (06) : 624 - 629
  • [4] Validation of the Hospital Survey on Patient Safety Culture 2.0 in Italian Hospitals: A Cross-Sectional Study of Healthcare Personnel Perceptions
    Bagnasco, Annamaria
    Catania, Gianluca
    Loiudice, Michele Tancredi
    Bellandi, Tommaso
    Cavaliere, Bruno
    Carzaniga, Sara
    Cardinali, Flavia
    Zanini, Milko
    Sasso, Loredana
    Working Grp Study
    JOURNAL OF ADVANCED NURSING, 2025,