Comparison of 4D Flow MRI and Particle Image Velocimetry Using an In Vitro Carotid Bifurcation Model

被引:0
|
作者
Rafael Medero
Carson Hoffman
Alejandro Roldán-Alzate
机构
[1] University of Wisconsin-Madison,Department of Mechanical Engineering
[2] University of Wisconsin-Madison,Department of Medical Physics
[3] University of Wisconsin-Madison,Department of Biomedical Engineering
[4] University of Wisconsin-Madison,Department of Radiology
来源
关键词
4D flow MRI; Experimental validation; Tomographic PIV; Stereoscopic PIV; Hemodynamics;
D O I
暂无
中图分类号
学科分类号
摘要
Four-dimensional (4D) Flow magnetic resonance imaging (MRI) enables the acquisition and assessment of complex hemodynamics in vivo from different vascular territories. This study investigated the viability of stereoscopic and tomographic particle image velocimetry (stereo- and tomo-PIV, respectively) as experimental validation techniques for 4D Flow MRI. The experiments were performed using continuous and pulsatile flows through an idealized carotid artery bifurcation model. Transverse and longitudinal planes were extracted from the acquired velocity data sets at different regions of interest and were analyzed with a point-by-point comparison. An overall root-mean-square error (RMSE) was calculated resulting in errors as low as 0.06 and 0.03 m/s when comparing 4D Flow MRI with stereo- and tomo-PIV, respectively. Quantitative agreement between techniques was determined by evaluating the relationship for individual velocity components and their magnitudes. These resulted in correlation coefficients (R2) of 4D Flow MRI with stereo- and tomo-PIV, as low as 0.76 and 0.73, respectively. The 3D velocity measurements from PIV showed qualitative agreement when compared to 4D Flow MRI, especially with tomo-PIV due to the addition of volumetric velocity measurements. These results suggest that tomo-PIV can be used as a validation technique for 4D Flow MRI, serving as the basis for future validation protocols.
引用
收藏
页码:2112 / 2122
页数:10
相关论文
共 50 条
  • [1] Comparison of 4D Flow MRI and Particle Image Velocimetry Using an In Vitro Carotid Bifurcation Model
    Medero, Rafael
    Hoffman, Carson
    Roldan-Alzate, Alejandro
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2018, 46 (12) : 2112 - 2122
  • [2] IN VITRO FLOW MEASUREMENTS IN ANATOMIC MODELS OF CAROTID ARTERY BIFURCATION, USING PARTICLE IMAGE VELOCIMETRY (PIV) TECHNIQUE
    Kabinejadian, Foad
    Leo, Hwa Liang
    Danpinid, Asawinee
    Cui, Fangsen
    Zhang, Zhe
    Ho, Pei
    [J]. ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [3] Comparison of Prospective and Retrospective Gated 4D Flow Cardiac MR Image Acquisitions in the Carotid Bifurcation
    Hurd, Elliott R.
    Han, Mengjiao
    Mendes, Jason K.
    Hadley, J. Rock
    Johnson, Chris R.
    Dibella, Edward V. R.
    Oshinski, John N.
    Timmins, Lucas H.
    [J]. CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2023, 14 (01) : 1 - 12
  • [4] Comparison of Prospective and Retrospective Gated 4D Flow Cardiac MR Image Acquisitions in the Carotid Bifurcation
    Elliott R. Hurd
    Mengjiao Han
    Jason K. Mendes
    J. Rock Hadley
    Chris R. Johnson
    Edward V. R. DiBella
    John N. Oshinski
    Lucas H. Timmins
    [J]. Cardiovascular Engineering and Technology, 2023, 14 : 1 - 12
  • [5] Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation
    Buchmann, N. A.
    Atkinson, C.
    Jeremy, M. C.
    Soria, J.
    [J]. EXPERIMENTS IN FLUIDS, 2011, 50 (04) : 1131 - 1151
  • [6] Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation
    N. A. Buchmann
    C. Atkinson
    M. C. Jeremy
    J. Soria
    [J]. Experiments in Fluids, 2011, 50 : 1131 - 1151
  • [7] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    [J]. RADIOLOGY, 2018, 289 (01) : 51 - 58
  • [8] Systematic Validation of the Echo Particle Image Velocimetry Technique Using a Patient Specific Carotid Bifurcation Model
    Zhang, Fuxing
    Lanning, Craig
    Mazzaro, Luciano
    Rech, Bryan
    Chen, Jiusheng
    Chen, S. James
    Shandas, Robin
    [J]. 2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 9 - +
  • [9] Comparison of Blood Flow Velocity Quantification by 4D Flow MR Imaging with Ultrasound at the Carotid Bifurcation
    Harloff, A.
    Zech, T.
    Wegent, F.
    Strecker, C.
    Weiller, C.
    Markl, M.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (07) : 1407 - 1413
  • [10] Transitional flow analysis in the carotid artery bifurcation by proper orthogonal decomposition and particle image velocimetry
    Kefayati, Sarah
    Poepping, Tamie L.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2013, 35 (07) : 898 - 909