Effects of different test apparati and heating procedures on the bond properties of post-installed rebar connections under elevated temperatures

被引:0
|
作者
G. Muciaccia
Diego Dongo Navarrete
N. Pinoteau
R. Mége
机构
[1] Politecnico di Milano,Department of Civil and Environmental Engineering
[2] Université Paris-Est,Centre Scientifique et Technique du Bâtiment
来源
Materials and Structures | 2019年 / 52卷
关键词
Post-installed rebar; Water vaporization; Pull-out; Post-curing;
D O I
暂无
中图分类号
学科分类号
摘要
The use of chemical bonds to fasten reinforcement bars in existing concrete structures has been widely developed in the previous years, showing in many cases higher bond values compared to cast in rebars due to better performance of the adhesive mortar. However, at elevated temperatures the concrete-adhesive bond tends to weaken endangering the construction under a fire situation. The paper presents the result of an experimental campaign carried out at Scientific and Technical Center of Building and Politecnico di Milano laboratories on a post-installed connection using vinyl-ester polymer. This paper aims to investigate the behavior of rebar connections through chemical resin when subjected to high temperatures, with particular emphasis on the effects of water vaporization in the concrete and on the influence of heating procedures on the mortar post-curing. Two different pull-out test procedures were adopted, differentiating each other for the loading and heating sequences. Results showed that specimens with the same water content may present different thermal gradients; however, comparable mean temperatures along the bar are detected for the same values of applied load. Moreover, for a given temperature, the increase of bond strength with exposure time showed a convergence towards an asymptotic value.
引用
收藏
相关论文
共 6 条
  • [1] Effects of different test apparati and heating procedures on the bond properties of post-installed rebar connections under elevated temperatures
    Muciaccia, G.
    Navarrete, Diego Dongo
    Pinoteau, N.
    Mege, R.
    [J]. MATERIALS AND STRUCTURES, 2019, 52 (02)
  • [2] Residual Strength of Organic Anchorage Adhesive for Post-installed Rebar at Elevated Temperatures and After Heating
    Zhang, Yu
    Lou, Guo-biao
    Chen, Ke-peng
    Li, Guo-qiang
    [J]. FIRE TECHNOLOGY, 2016, 52 (03) : 877 - 895
  • [3] Residual Strength of Organic Anchorage Adhesive for Post-installed Rebar at Elevated Temperatures and After Heating
    Yu Zhang
    Guo-biao Lou
    Ke-peng Chen
    Guo-qiang Li
    [J]. Fire Technology, 2016, 52 : 877 - 895
  • [4] Seismic Performance of Column-Foundation-Joints with Post-installed Rebar Connections: Pre-test Simulations
    Mahadik, Vinay
    Sharma, Akanshu
    Hofmann, Jan
    [J]. HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 1033 - 1040
  • [5] Local bond properties of reinforcement in concrete subjected to elevated temperatures: Effects of clear cover, bonded length and heating and loading procedures
    Muciaccia, Giovanni
    Consiglio, Andrea Nino
    [J]. ENGINEERING STRUCTURES, 2021, 230
  • [6] Mechanical properties of mild steel under combined effects of pre-damage and elevated temperatures in post-earthquake fire scenarios
    Lou, Ting
    Wang, Wei
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 189