Prevention and management of complications in descemet membrane endothelial keratoplasty (DMEK) and descemet stripping automated endothelial keratoplasty (DSAEK) [Komplikationsvermeidung und -management bei "descemet membrane endothelial keratoplasty" (DMEK) und "descemet stripping automated endothelial keratoplasty" (DSAEK)]

被引:0
|
作者
Cursiefen C. [1 ]
Steven P. [1 ]
Roters S. [1 ]
Heindl L.M. [1 ]
机构
[1] Universitätsaugenklinik Köln, Universität zu Köln, Kerpener Str. 62
来源
Der Ophthalmologe | 2013年 / 110卷 / 7期
关键词
Complications; Cornea; Fuchs' dystrophy; Intraoperative optical coherence tomography; Visual acuity;
D O I
10.1007/s00347-012-2679-8
中图分类号
学科分类号
摘要
Background. Posterior lamellar keratoplasty, in the form of Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK), has become a standard procedure for therapy of endothelial diseases of the cornea. The aim of this article is to describe strategies to prevent and manage complications in DMEK and DSAEK surgery.Methods. The article is based on a PubMed literature search and own clinical data. Key words used were DMEK, DSAEK, Descemet membrane endothelial keratoplasty and Descemet stripping automated endothelial keratoplasty. Results. The DMEK and DSAEK procedures are safe surgical strategies for treating endothelial corneal diseases if the indications are made correctly. Conclusions. The DMEK procedure is the standard procedure for improvement of visual acuity especially for younger patients with Fuchs' dystrophy and DSAEK is particularly suitable for eyes with complicated anterior chamber situations. © Springer-Verlag Berlin Heidelberg 2013.
引用
收藏
页码:614 / 621
页数:7
相关论文
共 50 条
  • [1] Prevention and management of complications in Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK)
    Cursiefen, C.
    Steven, P.
    Roters, S.
    Heindl, L. M.
    OPHTHALMOLOGE, 2013, 110 (07): : 614 - +
  • [2] Descemet's membrane endothelial keratoplasty (DMEK) versus Descemet's stripping automated endothelial keratoplasty (DSAEK) for corneal endothelial failure (Review)
    Stuart, Alastair J.
    Romano, Vito
    Virgili, Gianni
    Shortt, Alex J.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (06):
  • [3] Complications of Descemet Stripping Automated Endothelial Keratoplasty (DSAEK)
    Thiel, M. A.
    Bochmann, F.
    Schmittinger-Zirm, A.
    Baenninger, P. B.
    Schmid, M. K.
    Kaufmann, C.
    OPHTHALMOLOGE, 2015, 112 (12): : 969 - 973
  • [4] Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) vs Ultra-Thin DSAEK (UT-DSAEK) vs Descemet's Membrane Endothelial Keratoplasty (DMEK)
    Yan, Peng
    Teja, Salina
    Baig, Kashif
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial Keratoplasty
    Tourtas, Theofilos
    Laaser, Kathrin
    Bachmann, Bjoern O.
    Cursiefen, Claus
    Kruse, Friedrich E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (06) : 1082 - 1090
  • [6] Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty
    Woo, Jyh-Haur
    Ang, Marcus
    Htoon, Hla Myint
    Tan, Donald
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 207 : 288 - 303
  • [7] Descemet's stripping automated endothelial keratoplasty (DSAEK)
    Cursiefen, C.
    Kruse, F. E.
    OPHTHALMOLOGE, 2009, 106 (10): : 939 - 952
  • [8] Descemet's stripping with automated endothelial keratoplasty (DSAEK)
    Cursiefen, C.
    Kruse, F. E.
    OPHTHALMOLOGE, 2008, 105 (02): : 183 - +
  • [9] Outcomes of ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) performed in eyes with failure of primary Descemet membrane endothelial keratoplasty (DMEK)
    Graffi, Shmuel
    Leon, Pia
    Nahum, Yoav
    Gutfreund, Shay
    Spena, Rossella
    Mattioli, Leila
    Busin, Massimo
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (05) : 599 - 603
  • [10] Is Nanothin Descemet Stripping Automated Endothelial Keratoplasty Comparable to Descemet Membrane Endothelial Keratoplasty?
    Sahay, Pranita
    Singhal, Deepali
    Maharana, Prafulla K.
    Titiyal, Jeewan S.
    CORNEA, 2018, 37 (12) : E56 - E56