sFlt-1/PIGF ratio positive associated with non-dipper type change in ambulatory blood pressure monitoring(ABPM) for preeclampsia development

被引:0
|
作者
Yunshan Chen
Xiaodan Di
Guochun Xiang
Yunfeng Liu
Xiuyu Pan
Wenfeng Deng
Xiongjie Zhu
Ming Lei
Guozheng Zhang
Huishu Liu
机构
[1] Guangzhou Medical University,Department of Obstetrics, Guangzhou Women and Children’s Medical Center
[2] Southern Medical University,School of Health Management
[3] Guangzhou Medical University,Electrocardiographic Monitoring Unit, Guangzhou Women and Children’s Medical Center
[4] Guangzhou,undefined
来源
Hypertension Research | 2024年 / 47卷
关键词
PE; Ambulatory blood pressure monitoring; sFlt-1/PIGF ratio; Non-dipper type; Nocturnal BP;
D O I
暂无
中图分类号
学科分类号
摘要
In order to explore relationship of ambulatory blood pressure monitoring (ABPM) and soluble fms-like tyrosine kinase-1/placental growth factor (sFlt-1/PlGF) in suspected preeclampsia(PE), suspected PE participants in 28 + 0 to 33 + 6 weeks underwent ABPM and sFlt-1/PlGF from July 2020 to July 2022 were included(N = 476) in study. ABPM parameters were compared between sFlt-1/PlGF ≥38 and <38 groups. Correlation analysis was performed between ABPM and sFlt-1/PlGF, and logistic regression was used to explore prediction value for PE in 2 weeks. One hundred eighteen cases developed PE in 2 weeks with 114 from sFlt-1/PlGF ≥38 group. Daytime and nighttime BP were all increased,with increased non-dipper (58.4% vs. 30.3%), riser (22.1% vs. 13.1%) and and decreased Dipper (15.4% vs. 45.9%) type of ABPM in sFlt-1/PlGF ≥38 groups (P < 0.05).The riser group had the highest sFlt-1 and lowest PlGF. sFlt-1/PlGF and sFlt-1 were all positively correlated with systolic (SBP) & diastolic blood pressure(DBP)(P < 0.01), in which correlation coefficients of daytime and nighttime BP with sFlt-1 were β = 150.05 & 157.67 for SBP, β = 234 and 199.01 for DBP, respectively. However, PlGF was only negatively associated with nighttime SBP and DBP(P < 0.05), with no correlation with daytime BP (P > 0.05).Combining sFlt-1/PlGF and ABPM model, showed sFlt-1/PlGF (aOR = 2.01 (1.69–2.36)), Nighttime DBP (aOR = 1.14 (1.02–1.28)) contributed to preeclampsia prediction, and had improved predictive value compared to ABPM or sFlt-1/PlGF models alone(P < 0.05). sFlt-1/PlGF ratio was positively correlated with BP parameters, whereas PIGF was only negatively correlated with nocturnal BP and increased non-dipper type change in ABPM, which had a synergistic effect with sFlt-1/PlGF on PE prediction.
引用
收藏
页码:849 / 858
页数:9
相关论文
共 14 条
  • [1] sFlt-1/PIGF ratio positive associated with non-dipper type change in ambulatory blood pressure monitoring(ABPM) for preeclampsia development
    Chen, Yunshan
    Di, Xiaodan
    Xiang, Guochun
    Liu, Yunfeng
    Pan, Xiuyu
    Deng, Wenfeng
    Zhu, Xiongjie
    Lei, Ming
    Zhang, Guozheng
    Liu, Huishu
    HYPERTENSION RESEARCH, 2024, 47 (04) : 849 - 858
  • [2] More need to optimize the prediction model of sFlt-1/PIGF ratio and ambulatory blood pressure monitoring in preeclampsia
    Chen, Yunshan
    Pan, Xiuyu
    Xiang, Guochun
    Liu, Huishu
    HYPERTENSION RESEARCH, 2024, 47 (05) : 1438 - 1439
  • [3] More need to optimize the prediction model of sFlt- 1/PIGF ratio and ambulatory blood pressure monitoring in preeclampsia
    Yunshan Chen
    Xiuyu Pan
    Guochun Xiang
    Huishu Liu
    Hypertension Research, 2024, 47 : 1438 - 1439
  • [4] 24 hour ambulatory blood pressure monitoring in normotensive people with type 1 diabetes reveals non-dipper phenomena
    Mills, LS
    Gillibrand, WP
    Chattington, PD
    Vora, JP
    DIABETES, 2002, 51 : A507 - A507
  • [5] Utility of 24-hour ambulatory monitoring and the Sflt-1/PlGF ratio in preeclampsia prediction
    Walter Espeche
    Julian Minetto
    Martin R. Salazar
    Hypertension Research, 2024, 47 : 1436 - 1437
  • [6] Utility of 24-hour ambulatory monitoring and the Sflt-1/PlGF ratio in preeclampsia prediction
    Espeche, Walter
    Minetto, Julian
    Salazar, Martin R.
    HYPERTENSION RESEARCH, 2024, 47 (05) : 1436 - 1437
  • [7] Ambulatory blood pressure monitoring in normotensive obese females:: Factors for the non-dipper pattern.
    Silva-Nunes, J
    Bogalho, P
    Martin-Martins, J
    Gardete-Correia, L
    Nunes-Corrêa, J
    DIABETOLOGIA, 2000, 43 : A240 - A240
  • [8] Non-dipper effect in hypertense patients after renal transplantation by 24-hour ambulatory blood pressure monitoring
    Mendoza-Romo-Ramirez, Miguel A.
    Garcia-Hernandez, Jorge A.
    Rodriguez-Quilantan, Francisco J.
    Avila-Infante, Alejandro
    Bartolo-Sanchez, Fernando D.
    Silva-Ortiz, Josue A.
    Valdes-Mendez, Jose A.
    CIRUGIA Y CIRUJANOS, 2021, 89 (06): : 769 - 775
  • [9] NON-DIPPER PATTERN ON 24 HOURS AMBULATORY BLOOD PRESSURE MONITORING IN NORMOTENSIVE SUBJECTS IS ASSOCIATED WITH LOWER LEVEL OF HIGH-DENSITY CHOLESTEROL
    Isayeva, A. S.
    Matiashova, L.
    ATHEROSCLEROSIS, 2022, 355 : E267 - E267
  • [10] Characteristics of blood pressure and circadian pattern in HIV-infected patients using ambulatory blood pressure monitoring (ABPM). Importance of patient diary on dipper-non-dipper classification
    Mohr, R.
    Bernardino, J. I.
    Pena, J. M.
    Zamora, F. X.
    Perez-Valero, I.
    Gonzalez, J.
    Mora, M.
    Serrano, L.
    Gaya, F.
    Arribas, J. R.
    ANTIVIRAL THERAPY, 2010, 15 (08) : A47 - A48